Does Auditory Environment Predict Speech Perception Outcomes in Elderly Cochlear Implant Patients?

被引:2
|
作者
Chow, Kevin [1 ]
Kaul, Vivian F. [2 ]
Levine-Madoff, Jillian [3 ]
Wanna, George B. [2 ]
Cosetti, Maura K. [2 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Houston, TX 77030 USA
[2] New York Eye & Ear Infirm Mt Sinai, Ear Inst, Icahn Sch Med, Dept Otolaryngol Head & Neck Surg, New York, NY 10003 USA
[3] Northwell Sch Med, Dept Otolaryngol Head & Neck Surg, New York, NY USA
关键词
Cochlear implants; Data logging; Presbycusis; Speech perception; Aging;
D O I
10.1159/000513637
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Introduction: Cochlear implantation (CI) is a reliable and safe means by which sensorineural hearing loss can be ameliorated in the elderly population. However, a high degree of variation exists in postimplantation hearing outcomes for which some modifiable factors of the daily natural auditory environment may be contributory. In this study, we analyze the relationship between cochlear implant patient age, natural auditory environment, and postimplantation speech perception among older adults. Methods: Data log from automatic environment classification enabled sound processors of postlingually deafened CI recipients >= 50 years old (n = 115) were obtained retrospectively and analyzed for time spent (hours per day) in listening environment and loudness (SPL dB). Speech perception testing was assessed in a subset of patients (n = 27) using open-set word recognition in quiet Consonant-Nucleus-Consonant in the short and intermediate postoperative period. Results: The mean subject age was 70 years (range, 53-99 years). Average daily implant use was 10.8 h and was not significantly correlated with age (p = 0.23, Spearman's rho). Age was positively correlated with the percentage of hours spent at <40 and 40-50 dB and negatively correlated to proportional CI use at higher volume (60-70, 70-80, and >80 dB; r(s) = 0.21, 0.20, -0.20, -0.35, -0.43; p = 0.021, 0.036, 0.033, <0.001, <0.001, respectively). Age was positively correlated with CI use in the quiet scene (r(s) = 0.26, p = 0.006) and negatively correlated with scenes containing speech and noise (r(s) = -0.19, -0.25; p = 0.046, 0.007). Total hours of device use and time spent at <40, 40-50 dB, and quiet environments were significantly correlated with improved CNC word scores (r(s) = 0.48, 0.48, 0.51; p = 0.01, 0.01, <0.01, Spearman's rho). While all speech (speech in noise + speech) was not significantly correlated to improvements in speech perception, a medium effect size was observed (r(s) = 0.37, p = 0.057). Discussion/Conclusion: This study supports a relationship between auditory environment and age, with older CI recipients spending a greater proportion of time in quiet. Older CI users demonstrated greater improvements in speech perception with longer daily device use. Additional examination of the relationship between auditory environment and speech perception is necessary to conclusively guide future auditory rehabilitation efforts.
引用
收藏
页码:378 / 386
页数:9
相关论文
共 50 条
  • [41] AUDITORY VISUAL SPEECH-PERCEPTION BY COCHLEAR IMPLANT USERS AND HEARING-AID WEARERS
    DANHAUER, JL
    ERRATT, JD
    EDGERTON, BJ
    AMERICAN JOURNAL OF OTOLOGY, 1986, 7 (05): : 354 - 360
  • [42] Auditory-visual speech perception in normal-hearing and cochlear-implant listeners
    Desai, Sheetal
    Stickney, Ginger
    Zeng, Fan-Gang
    Journal of the Acoustical Society of America, 2008, 123 (01): : 428 - 440
  • [43] Auditory perception in pediatric cochlear implant users with cochlear nerve hypoplasia
    Uzun, Erva Degirmenci
    Batuk, Merve Ozbal
    D'Alessandrob, Hilal Dincer
    Sennaroglu, Gonca
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2022, 160
  • [44] Suitability of Auditory Speech Sound Evaluation (A§E®) in German cochlear implant patients
    Diana Arweiler-Harbeck
    Sandra Janeschik
    Stephan Lang
    Heike Bagus
    European Archives of Oto-Rhino-Laryngology, 2011, 268 : 1259 - 1266
  • [45] Suitability of Auditory Speech Sound Evaluation (AAEA®) in German cochlear implant patients
    Arweiler-Harbeck, Diana
    Janeschik, Sandra
    Lang, Stephan
    Bagus, Heike
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2011, 268 (09) : 1259 - 1266
  • [46] The Auditory Perception of Consonant Contrasts in Cochlear Implant Children
    Mahnaz Eshaghi
    Akbar Darouie
    Robab Teymouri
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2022, 74 : 455 - 459
  • [47] The Auditory Perception of Consonant Contrasts in Cochlear Implant Children
    Eshaghi, Mahnaz
    Darouie, Akbar
    Teymouri, Robab
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2022, 74 (SUPPL 1) : 455 - 459
  • [48] The Effect of Technology and Testing Environment on Speech Perception Using Telehealth With Cochlear Implant Recipients
    Goehring, Jenny L.
    Hughes, Michelle L.
    Baudhuin, Jacquelyn L.
    Valente, Daniel L.
    McCreery, Ryan W.
    Diaz, Gina R.
    Sanford, Todd
    Harpster, Roger
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2012, 55 (05): : 1373 - 1386
  • [49] Review of Speech Outcomes in Cochlear Implant Recipients at a Nascent Cochlear Implant Program
    Aminpour, Nathan
    Levin, Laura
    Finkbone, Mary
    Morikawa, Michael
    Blumgart, Melissa
    Kim, H. Jeffrey
    Hoa, Michael
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (02)
  • [50] Auditory plasticity in cochlear implant patients
    Kubo, T
    Iwaki, T
    Ohkusa, M
    Doi, K
    Uno, A
    Yamamoto, K
    Fujii, K
    ACTA OTO-LARYNGOLOGICA, 1996, 116 (02) : 224 - 227