Does Auditory Environment Predict Speech Perception Outcomes in Elderly Cochlear Implant Patients?

被引:2
|
作者
Chow, Kevin [1 ]
Kaul, Vivian F. [2 ]
Levine-Madoff, Jillian [3 ]
Wanna, George B. [2 ]
Cosetti, Maura K. [2 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Houston, TX 77030 USA
[2] New York Eye & Ear Infirm Mt Sinai, Ear Inst, Icahn Sch Med, Dept Otolaryngol Head & Neck Surg, New York, NY 10003 USA
[3] Northwell Sch Med, Dept Otolaryngol Head & Neck Surg, New York, NY USA
关键词
Cochlear implants; Data logging; Presbycusis; Speech perception; Aging;
D O I
10.1159/000513637
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Introduction: Cochlear implantation (CI) is a reliable and safe means by which sensorineural hearing loss can be ameliorated in the elderly population. However, a high degree of variation exists in postimplantation hearing outcomes for which some modifiable factors of the daily natural auditory environment may be contributory. In this study, we analyze the relationship between cochlear implant patient age, natural auditory environment, and postimplantation speech perception among older adults. Methods: Data log from automatic environment classification enabled sound processors of postlingually deafened CI recipients >= 50 years old (n = 115) were obtained retrospectively and analyzed for time spent (hours per day) in listening environment and loudness (SPL dB). Speech perception testing was assessed in a subset of patients (n = 27) using open-set word recognition in quiet Consonant-Nucleus-Consonant in the short and intermediate postoperative period. Results: The mean subject age was 70 years (range, 53-99 years). Average daily implant use was 10.8 h and was not significantly correlated with age (p = 0.23, Spearman's rho). Age was positively correlated with the percentage of hours spent at <40 and 40-50 dB and negatively correlated to proportional CI use at higher volume (60-70, 70-80, and >80 dB; r(s) = 0.21, 0.20, -0.20, -0.35, -0.43; p = 0.021, 0.036, 0.033, <0.001, <0.001, respectively). Age was positively correlated with CI use in the quiet scene (r(s) = 0.26, p = 0.006) and negatively correlated with scenes containing speech and noise (r(s) = -0.19, -0.25; p = 0.046, 0.007). Total hours of device use and time spent at <40, 40-50 dB, and quiet environments were significantly correlated with improved CNC word scores (r(s) = 0.48, 0.48, 0.51; p = 0.01, 0.01, <0.01, Spearman's rho). While all speech (speech in noise + speech) was not significantly correlated to improvements in speech perception, a medium effect size was observed (r(s) = 0.37, p = 0.057). Discussion/Conclusion: This study supports a relationship between auditory environment and age, with older CI recipients spending a greater proportion of time in quiet. Older CI users demonstrated greater improvements in speech perception with longer daily device use. Additional examination of the relationship between auditory environment and speech perception is necessary to conclusively guide future auditory rehabilitation efforts.
引用
收藏
页码:378 / 386
页数:9
相关论文
共 50 条
  • [31] Analysis of speech perception by patients with a 22-channel cochlear implant
    Funasaka, S
    BIOMEDICAL RESEARCH-TOKYO, 1997, 18 : 101 - 114
  • [32] Speech discrimination in elderly cochlear implant users
    Nakajima, S
    Iwaki, S
    Fujisawa, N
    Yamaguchi, S
    Kawano, M
    Fujiki, N
    Naito, Y
    Honjo, I
    UPDATES IN COCHLEAR IMPLANTATION, 2000, 57 : 368 - 369
  • [33] Music perception and its correlation with auditory speech perception in pediatric Mandarin-speaking cochlear implant users
    Lu, Yunyi
    Wu, Yutong
    Zeng, Dong
    Chen, Chi
    Bian, Panpan
    Xu, Baicheng
    ACTA OTO-LARYNGOLOGICA, 2025, 145 (01) : 51 - 58
  • [34] Speech recognition in elderly cochlear implant recipients
    Pasanisi, E
    Bacciu, A
    Vincenti, V
    Guida, M
    Barbot, A
    Berghenti, MT
    Bacciu, S
    CLINICAL OTOLARYNGOLOGY, 2003, 28 (02): : 154 - 157
  • [35] Cochlear implant outcomes in the very elderly
    Bourn, Stephanie S.
    Goldstein, Mary Rose
    Morris, Sarah A.
    Jacob, Abraham
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2022, 43 (01)
  • [36] Pure-tone auditory stream segregation and speech perception in noise in cochlear implant recipients
    Hong, Robert S.
    Turner, Christopher W.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 120 (01): : 360 - 374
  • [37] Auditory perception and speech production skills of children with cochlear implant assessed by means of questionnaire batteries
    Kubo, Takeshi
    Iwaki, Takako
    Sasaki, Tomo
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2008, 70 (04): : 224 - 228
  • [38] Pure-tone auditory stream segregation and speech perception in noise in cochlear implant recipients
    Hong, Robert S.
    Turner, Christopher W.
    Journal of the Acoustical Society of America, 2006, 120 (01): : 360 - 374
  • [39] Auditory-visual speech perception in normal-hearing and cochlear-implant listeners
    Desai, Sheetal
    Stickney, Ginger
    Zeng, Fan-Gang
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 123 (01): : 428 - 440
  • [40] Cortical auditory evoked potential in cochlear implant users: An objective method to improve speech perception
    Tavora-Vieira, Dayse
    Wedekind, Andre
    Ffoulkes, Ellen
    Voola, Marcus
    Marino, Roberta
    PLOS ONE, 2022, 17 (10):