Does Auditory Environment Predict Speech Perception Outcomes in Elderly Cochlear Implant Patients?

被引:2
|
作者
Chow, Kevin [1 ]
Kaul, Vivian F. [2 ]
Levine-Madoff, Jillian [3 ]
Wanna, George B. [2 ]
Cosetti, Maura K. [2 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Houston, TX 77030 USA
[2] New York Eye & Ear Infirm Mt Sinai, Ear Inst, Icahn Sch Med, Dept Otolaryngol Head & Neck Surg, New York, NY 10003 USA
[3] Northwell Sch Med, Dept Otolaryngol Head & Neck Surg, New York, NY USA
关键词
Cochlear implants; Data logging; Presbycusis; Speech perception; Aging;
D O I
10.1159/000513637
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Introduction: Cochlear implantation (CI) is a reliable and safe means by which sensorineural hearing loss can be ameliorated in the elderly population. However, a high degree of variation exists in postimplantation hearing outcomes for which some modifiable factors of the daily natural auditory environment may be contributory. In this study, we analyze the relationship between cochlear implant patient age, natural auditory environment, and postimplantation speech perception among older adults. Methods: Data log from automatic environment classification enabled sound processors of postlingually deafened CI recipients >= 50 years old (n = 115) were obtained retrospectively and analyzed for time spent (hours per day) in listening environment and loudness (SPL dB). Speech perception testing was assessed in a subset of patients (n = 27) using open-set word recognition in quiet Consonant-Nucleus-Consonant in the short and intermediate postoperative period. Results: The mean subject age was 70 years (range, 53-99 years). Average daily implant use was 10.8 h and was not significantly correlated with age (p = 0.23, Spearman's rho). Age was positively correlated with the percentage of hours spent at <40 and 40-50 dB and negatively correlated to proportional CI use at higher volume (60-70, 70-80, and >80 dB; r(s) = 0.21, 0.20, -0.20, -0.35, -0.43; p = 0.021, 0.036, 0.033, <0.001, <0.001, respectively). Age was positively correlated with CI use in the quiet scene (r(s) = 0.26, p = 0.006) and negatively correlated with scenes containing speech and noise (r(s) = -0.19, -0.25; p = 0.046, 0.007). Total hours of device use and time spent at <40, 40-50 dB, and quiet environments were significantly correlated with improved CNC word scores (r(s) = 0.48, 0.48, 0.51; p = 0.01, 0.01, <0.01, Spearman's rho). While all speech (speech in noise + speech) was not significantly correlated to improvements in speech perception, a medium effect size was observed (r(s) = 0.37, p = 0.057). Discussion/Conclusion: This study supports a relationship between auditory environment and age, with older CI recipients spending a greater proportion of time in quiet. Older CI users demonstrated greater improvements in speech perception with longer daily device use. Additional examination of the relationship between auditory environment and speech perception is necessary to conclusively guide future auditory rehabilitation efforts.
引用
收藏
页码:378 / 386
页数:9
相关论文
共 50 条
  • [1] Audiovisual speech perception in elderly cochlear implant recipients
    Hay-McCutcheon, MJ
    Pisoni, DB
    Kirk, KI
    LARYNGOSCOPE, 2005, 115 (10): : 1887 - 1894
  • [2] Auditory cortical activation and speech perception in cochlear implant users
    Green, K. M. J.
    Julyan, P. J.
    Hastings, D. L.
    Ramsden, R. T.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2008, 122 (03): : 238 - 245
  • [3] The speech perception gap in cochlear implant patients
    Franks, Zechariah G.
    Jacob, Abraham
    COCHLEAR IMPLANTS INTERNATIONAL, 2019, 20 (04) : 176 - 181
  • [4] Auditory Speech Perception Tests in Relation to the Coding Strategy in Cochlear Implant
    Bazon, Aline Cristine
    Mantello, Erika Barioni
    Goncales, Alina Sanches
    Isaac, Myriam de Lima
    Hyppolito, Miguel Angelo
    Mirandola Barbosa Reis, Ana Claudia
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2016, 20 (03) : 254 - 260
  • [5] The Effect of Cochlear Coverage on Auditory and Speech Performance in Cochlear Implant Patients
    Doubi, Aseel
    Almuhawas, Fida
    Alzhrani, Farid
    Doubi, Motaz
    Aljutaili, Hamad
    Hagr, Abdulrahman
    OTOLOGY & NEUROTOLOGY, 2019, 40 (05) : 602 - 607
  • [6] Effects of residual speech and auditory deprivation on speech perception of adult cochlear implant recipients
    Derinsu, Ufuk
    Yuksel, Mustafa
    Gecici, Cennet Reyyan
    Ciprut, Ayca
    Akdeniz, Esra
    AURIS NASUS LARYNX, 2019, 46 (01) : 58 - 63
  • [7] Speech perception and auditory performance following cochlear implantation in elderly Koreans
    Lee, Sungsu
    Park, Hyong-Joo
    Cho, Hyong-Ho
    Cho, Yong-Beom
    ENT-EAR NOSE & THROAT JOURNAL, 2017, 96 (03) : 112 - +
  • [8] Cochlear Implant in the Elderly: Results in Terms of Speech Perception and Quality of Life
    Forli, Francesca
    Lazzerini, Francesco
    Fortunato, Susanna
    Bruschini, Luca
    Berrettini, Stefano
    AUDIOLOGY AND NEURO-OTOLOGY, 2019, 24 (02) : 77 - 83
  • [9] Long-term Speech Perception in Elderly Cochlear Implant Users
    Dillon, Margaret T.
    Buss, Emily
    Adunka, Marcia C.
    King, English R.
    Pillsbury, Harold C., III
    Adunka, Oliver F.
    Buchman, Craig A.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2013, 139 (03) : 279 - 283
  • [10] Speech perception in elderly patients following cochlear implantation
    Haensel, J
    Ilgner, J
    Chen, YS
    Thuermer, C
    Westhofen, M
    ACTA OTO-LARYNGOLOGICA, 2005, 125 (12) : 1272 - 1276