A Randomized Trial of Continuous Noninvasive Blood Pressure Monitoring During Noncardiac Surgery

被引:114
|
作者
Maheshwari, Kamal [1 ,2 ]
Khanna, Sandeep [2 ]
Bajracharya, Gausan Ratna [1 ]
Makarova, Natalya [3 ]
Riter, Quinton [1 ]
Raza, Syed [1 ]
Cywinski, Jacek B. [2 ]
Argalious, Maged [2 ]
Kurz, Andrea [1 ,2 ]
Sessler, Daniel I. [1 ]
机构
[1] Cleveland Clin, Dept Outcomes Res, Inst Anesthesiol, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Gen Anesthesiol, Inst Anesthesiol, Cleveland, OH 44195 USA
[3] Cleveland Clin, Dept Quantitat Hlth Sci & Outcomes Res, Inst Anesthesiol, Cleveland, OH 44195 USA
来源
ANESTHESIA AND ANALGESIA | 2018年 / 127卷 / 02期
关键词
INTRAOPERATIVE HYPOTENSION; ARTERIAL-PRESSURE; MAJOR SURGERY; ACUTE KIDNEY; MORTALITY; ASSOCIATION; DEFINITION; ANESTHESIA; MANAGEMENT; STABILITY;
D O I
10.1213/ANE.0000000000003482
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Intraoperative hypotension is associated with postoperative mortality. Early detection of hypotension by continuous hemodynamic monitoring might prompt timely therapy, thereby reducing intraoperative hypotension. We tested the hypothesis that continuous noninvasive blood pressure monitoring reduces intraoperative hypotension. METHODS: Patients 45 years old with American Society of Anesthesiologists physical status III or IV having moderate-to-high-risk noncardiac surgery with general anesthesia were included. All participating patients had continuous noninvasive hemodynamic monitoring using a finger cuff (ClearSight, Edwards Lifesciences, Irvine, CA) and a standard oscillometric cuff. In half the patients, randomly assigned, clinicians were blinded to the continuous values, whereas the others (unblinded) had access to continuous blood pressure readings. Continuous pressures in both groups were used for analysis. Time-weighted average for mean arterial pressure <65 mm Hg was compared using 2-sample Wilcoxon rank-sum tests and Hodges Lehmann estimation of location shift with corresponding asymptotic 95% CI. RESULTS: Among 320 randomized patients, 316 were included in the intention-to-treat analysis. With 158 patients in each group, those assigned to continuous blood pressure monitoring had significantly lower time-weighted average mean arterial pressure <65 mm Hg, 0.05 [0.00, 0.22] mm Hg, versus intermittent blood pressure monitoring, 0.11 [0.00, 0.54] mm Hg (P = .039, significance criteria P < .048). CONCLUSIONS: Continuous noninvasive hemodynamic monitoring nearly halved the amount of intraoperative hypotension. Hypotension reduction with continuous monitoring, while statistically significant, is currently of uncertain clinical importance.
引用
收藏
页码:424 / 431
页数:8
相关论文
共 50 条
  • [41] Efficacy of Home Blood Pressure Monitoring on Blood Pressure Control: A Randomized Controlled Trial
    Fuchs, Sandra C.
    Fuchs, Flavio D.
    Moreira, Leila B.
    Gus, Miguel
    Wiehe, Mario
    Fuchs, Felipe C.
    Ferreira, Andre
    Neyeloff, Jeruza L.
    CIRCULATION, 2010, 122 (02) : E78 - E78
  • [42] CONTINUOUS BLOOD-PRESSURE MONITORING DURING HEMODIALYSIS
    AGISHI, T
    KANEKO, I
    KUMAGAI, E
    OTA, K
    ARTIFICIAL ORGANS, 1979, 3 (03) : 237 - 240
  • [43] CONTINUOUS MONITORING OF BLOOD PRESSURE DURING CEREBRAL ANGIOGRAPHY
    DECK, MDF
    FERGUSON, R
    POTTS, DG
    RADIOLOGY, 1971, 99 (02) : 349 - &
  • [44] Noninvasive mean blood pressure monitoring
    Lakhanko, L
    Polonetsky, L
    Sidorenko, G
    Vorobiov, A
    EUROPEAN HEART JOURNAL, 2000, 21 : 103 - 103
  • [45] Perioperative Noninvasive Blood Pressure Monitoring
    Kuck, Kai
    Baker, Philip D.
    ANESTHESIA AND ANALGESIA, 2018, 127 (02): : 408 - 411
  • [46] A Noninvasive Blood Pressure Monitoring System
    Balamurugan
    Reddy, S. Ramasubba
    Muthan, S.
    2016 IEEE INTERNATIONAL CONFERENCE ON RECENT TRENDS IN ELECTRONICS, INFORMATION & COMMUNICATION TECHNOLOGY (RTEICT), 2016, : 1999 - 2001
  • [47] Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy
    Sakai, Yoko
    Tsutsumi, Yasuo M.
    Oyama, Takuro
    Murakami, Chiaki
    Kakuta, Nami
    Tanaka, Katsuya
    JOURNAL OF MEDICAL INVESTIGATION, 2018, 65 (1-2): : 69 - 73
  • [48] Continuous peri-operative glucose monitoring in noncardiac surgery
    Putzu, Alessandro
    Grange, Elliot
    Schorer, Raoul
    Schiffer, Eduardo
    Gariani, Karim
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2025, 42 (02) : 162 - 171
  • [49] Noninvasive monitoring of blood pressure by instantaneous CNAP® during carotid endarterectomy
    Huynh, T. M.
    Joachim, J.
    Assenzo, V.
    Pirrachio, R.
    Safran, D.
    Cholley, B.
    Julia, P.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2014, 33 : A246 - A246
  • [50] Noninvasive Sensor for Continuous intraocular Pressure Monitoring
    Lei, Shujing
    Zhang, Lei
    Fei, Gao
    Fan, Lei
    Dong, Helei
    Tan, Qiulin
    Xiong, Jijun
    Shen, Sanmin
    SENSORS AND MATERIALS, 2018, 30 (12) : 2811 - 2821