A Randomized Trial of Continuous Noninvasive Blood Pressure Monitoring During Noncardiac Surgery

被引:114
|
作者
Maheshwari, Kamal [1 ,2 ]
Khanna, Sandeep [2 ]
Bajracharya, Gausan Ratna [1 ]
Makarova, Natalya [3 ]
Riter, Quinton [1 ]
Raza, Syed [1 ]
Cywinski, Jacek B. [2 ]
Argalious, Maged [2 ]
Kurz, Andrea [1 ,2 ]
Sessler, Daniel I. [1 ]
机构
[1] Cleveland Clin, Dept Outcomes Res, Inst Anesthesiol, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Gen Anesthesiol, Inst Anesthesiol, Cleveland, OH 44195 USA
[3] Cleveland Clin, Dept Quantitat Hlth Sci & Outcomes Res, Inst Anesthesiol, Cleveland, OH 44195 USA
来源
ANESTHESIA AND ANALGESIA | 2018年 / 127卷 / 02期
关键词
INTRAOPERATIVE HYPOTENSION; ARTERIAL-PRESSURE; MAJOR SURGERY; ACUTE KIDNEY; MORTALITY; ASSOCIATION; DEFINITION; ANESTHESIA; MANAGEMENT; STABILITY;
D O I
10.1213/ANE.0000000000003482
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Intraoperative hypotension is associated with postoperative mortality. Early detection of hypotension by continuous hemodynamic monitoring might prompt timely therapy, thereby reducing intraoperative hypotension. We tested the hypothesis that continuous noninvasive blood pressure monitoring reduces intraoperative hypotension. METHODS: Patients 45 years old with American Society of Anesthesiologists physical status III or IV having moderate-to-high-risk noncardiac surgery with general anesthesia were included. All participating patients had continuous noninvasive hemodynamic monitoring using a finger cuff (ClearSight, Edwards Lifesciences, Irvine, CA) and a standard oscillometric cuff. In half the patients, randomly assigned, clinicians were blinded to the continuous values, whereas the others (unblinded) had access to continuous blood pressure readings. Continuous pressures in both groups were used for analysis. Time-weighted average for mean arterial pressure <65 mm Hg was compared using 2-sample Wilcoxon rank-sum tests and Hodges Lehmann estimation of location shift with corresponding asymptotic 95% CI. RESULTS: Among 320 randomized patients, 316 were included in the intention-to-treat analysis. With 158 patients in each group, those assigned to continuous blood pressure monitoring had significantly lower time-weighted average mean arterial pressure <65 mm Hg, 0.05 [0.00, 0.22] mm Hg, versus intermittent blood pressure monitoring, 0.11 [0.00, 0.54] mm Hg (P = .039, significance criteria P < .048). CONCLUSIONS: Continuous noninvasive hemodynamic monitoring nearly halved the amount of intraoperative hypotension. Hypotension reduction with continuous monitoring, while statistically significant, is currently of uncertain clinical importance.
引用
收藏
页码:424 / 431
页数:8
相关论文
共 50 条
  • [21] Noninvasive blood pressure monitoring in patients with continuous flow rotary LVAD
    Wieselthaler, G.M.
    Hiesmayr, M.
    Reindl, C.
    Schima, H.
    ASAIO Journal, 2000, 46 (02)
  • [22] NONINVASIVE CONTINUOUS BLOOD-PRESSURE MONITORING BY THE UNLOADING OF VASCULAR WALL
    WANG, MH
    CHEUNG, PW
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1417 - 1418
  • [23] CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITORING IN PATIENTS WITH SLEEP DISORDERS
    PENZEL, T
    MAYER, J
    PETER, JH
    PODSZUS, T
    VOIGT, KH
    VONWICHERT, P
    PHYSIOLOGICAL RESEARCH, 1992, 41 (01) : 11 - 17
  • [24] Noninvasive Continuous Blood Pressure Measurement and GPS Position Monitoring of Patients
    Krejcar, Ondrej
    Slanina, Zdenek
    Stambachr, Jan
    Silber, Petr
    Frischer, Robert
    2009 IEEE 70TH VEHICULAR TECHNOLOGY CONFERENCE FALL, VOLS 1-4, 2009, : 3 - +
  • [25] EXTERNAL CONTINUOUS BLOOD PRESSURE MONITORING DEVICE TRIAL
    Boone, Kirsten
    Yamane, David
    Payette, Christopher J.
    Mccarville, Patrick
    Bryan, Amelia
    Winsten, Samuel
    Campbell, Abraham P.
    Levitt, Catherine
    CHEST, 2024, 166 (04) : 157A - 158A
  • [26] NONINVASIVE CONTINUOUS BLOOD PRESSURE MONITORING COMPARED TO INVASIVE BLOOD PRESSURE MONITORING: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Kim, Sang-Hyun
    Lilot, Marc
    Sidhu, Kulraj
    Cannesson, Maxime
    ANESTHESIA AND ANALGESIA, 2013, 117 : 32 - 33
  • [27] Noninvasive, continuous monitoring of blood cultures
    Sandin, RL
    INFECTIONS IN MEDICINE, 1999, 16 (06) : 389 - 392
  • [28] NONINVASIVE ESTIMATION OF THE BLOOD PRESSURE WAVEFORM IN THE CAROTID ARTERY USING CONTINUOUS FINGER BLOOD PRESSURE MONITORING
    Idzenga, Tim
    Reesink, Koen D.
    van Swelm, Youri
    Hansen, Hendrik H. G.
    Holewijn, Suzanne
    de Korte, Chris L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (11): : 1998 - 2006
  • [29] Cardiopres®:: A novel method of noninvasive, continuous, ambulatory blood pressure and ECG monitoring
    Boon, D
    van Goudoever, J
    van Montfrans, GA
    JOURNAL OF HYPERTENSION, 2002, 20 : S224 - S224
  • [30] Noninvasive continuous or intermittent blood pressure and heart rate patient monitoring in the ED
    Nowak, Richard M.
    Sen, Ayan
    Garcia, Audwin J.
    Wilkie, Heidi
    Yang, James J.
    Nowak, Michael R.
    Moyer, Michele L.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 29 (07): : 782 - 789