A model to predict the improvement of automated blood culture bacterial detection by doubling platelet sample volume

被引:28
|
作者
Wagner, Stephen J.
Eder, Anne E.
机构
[1] Amer Red Cross, Blood Components Dept, Holland Lab Biomed Sci, Rockville, MD 20855 USA
[2] Amer Red Cross, Blood Serv, Med Off, Washington, DC 20006 USA
关键词
D O I
10.1111/j.1537-2995.2007.01132.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Some transmissions of bacterial infection from platelet (PLT) transfusion have occurred since introduction of automated blood culturing of apheresis PLTs. The majority of these cases involved false-negative culture results in which slow-growing Staphylococcus organisms were implicated. This study analyses the projected benefit in detecting slow growing organisms by increasing sample volume from 4 to 8 mL. STUDY DESIGN AND METHODS: Bacterial growth was modeled by varying the initial inoculum, doubling time, and lag time. The numbers of organisms present at a 24-hour sampling time were calculated. Poisson analysis was used to determine the fraction of 4- or 8-mL samples that could be detected because they contained organisms. For each inoculum, the percentage of improved detection by doubling sample volume was defined as delta, the difference between the percentage of detection of 8- and 4-mL samples. RESULTS: The maximum improvement in detection by doubling sample volume was 25 percent and did not depend on bacterial growth rate or lag time. As inocula increased toward 40 colony-forming units per unit, delta decreased. As lag and doubling times increased, inocula corresponding to maximum delta increased and the width of the distribution curve broadened. CONCLUSION: Doubling sample volume will not double the chance of detecting slow growing organisms, but instead is predicted to improve detection by 25 percent or less.
引用
收藏
页码:430 / 433
页数:4
相关论文
共 50 条
  • [41] Blood surveillance and detection on platelet bacterial contamination associated with septic events
    Hsueh, J. C.
    Ho, C. F.
    Chang, S. H.
    Pan, F. Z.
    Chen, S. C.
    Shi, M. D.
    Chien, S. T.
    TRANSFUSION MEDICINE, 2009, 19 (06) : 350 - 356
  • [42] Detection of bacterial contamination in whole-blood derived platelet concentrates
    Grave, L
    Raimondo, A
    Nannini, P
    Besson-Faure, I
    TRANSFUSION, 2004, 44 (09) : 51A - 51A
  • [43] Automated analysis of feline platelets in whole blood, including platelet count, mean platelet volume, and activation state
    Zelmanovic, D
    Hetherington, EJ
    VETERINARY CLINICAL PATHOLOGY, 1998, 27 (01) : 2 - 9
  • [44] Validation of the Versatrek blood culture detection system for detection of bacterial contamination of platelets
    Gonzales, R
    Dunham, L
    Mark, O
    Woodell, P
    Hall, A
    Vanbrakle, R
    Sconce, K
    Seymour, H
    Chan, C
    Feige, L
    Beardsley, S
    Craft, D
    TRANSFUSION, 2004, 44 (09) : 47A - 47A
  • [45] A new culture bag set for bacterial detection in leukoreduced platelet transfusion products
    Cortus, MA
    Chong, C
    Carmen, R
    Monsale, R
    Guccione, A
    Rasalan, T
    Auci, D
    Ayarza, S
    Ortolano, G
    Wenz, B
    Freundlich, L
    TRANSFUSION, 2001, 41 (09) : 33S - 33S
  • [46] Evaluation of an automated microbiologic blood culture device for detection of bacteria in platelet components. (vol 38, pg 674, 1998)
    Wagner, SJ
    Robinette, D
    TRANSFUSION, 1998, 38 (09) : 898 - 898
  • [47] Nutrient supplementation of culture media improves the detection of Cutibacterium acnes in platelet components by an automated culture system
    Kumaran, Dilini
    Ramirez-Arcos, Sandra
    VOX SANGUINIS, 2023, 118 (11) : 930 - 937
  • [48] Comparable bacterial growth in platelet concentrates suspended in plasma and platelet additive solution and improved detection of bacterial contamination using a new generation automated culture system( vol 64 , pg 665 , 2024)
    Kou, Y.
    Kumaran, D.
    Howell, A.
    Ramirez-Arcos, S.
    TRANSFUSION, 2024, 64 (09) : 1808 - 1809
  • [49] EARLY DETECTION OF BACTERIAL-GROWTH IN BLOOD CULTURE BY IMPEDANCE MONITORING WITH A BACTOMETER MODEL-32
    BUCKLAND, A
    KESSOCKPHILIP, S
    BASCOMB, S
    JOURNAL OF CLINICAL PATHOLOGY, 1983, 36 (07) : 823 - 828
  • [50] Optimizing Blood Culture Volume Collection in Inpatient Pediatrics: A Quality Improvement Study
    Lo, Claire
    Banerjee, Ritu
    Humphries, Romney
    Boyle, Katharine
    PEDIATRICS, 2022, 149 (01)