A model to predict the improvement of automated blood culture bacterial detection by doubling platelet sample volume

被引:28
|
作者
Wagner, Stephen J.
Eder, Anne E.
机构
[1] Amer Red Cross, Blood Components Dept, Holland Lab Biomed Sci, Rockville, MD 20855 USA
[2] Amer Red Cross, Blood Serv, Med Off, Washington, DC 20006 USA
关键词
D O I
10.1111/j.1537-2995.2007.01132.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Some transmissions of bacterial infection from platelet (PLT) transfusion have occurred since introduction of automated blood culturing of apheresis PLTs. The majority of these cases involved false-negative culture results in which slow-growing Staphylococcus organisms were implicated. This study analyses the projected benefit in detecting slow growing organisms by increasing sample volume from 4 to 8 mL. STUDY DESIGN AND METHODS: Bacterial growth was modeled by varying the initial inoculum, doubling time, and lag time. The numbers of organisms present at a 24-hour sampling time were calculated. Poisson analysis was used to determine the fraction of 4- or 8-mL samples that could be detected because they contained organisms. For each inoculum, the percentage of improved detection by doubling sample volume was defined as delta, the difference between the percentage of detection of 8- and 4-mL samples. RESULTS: The maximum improvement in detection by doubling sample volume was 25 percent and did not depend on bacterial growth rate or lag time. As inocula increased toward 40 colony-forming units per unit, delta decreased. As lag and doubling times increased, inocula corresponding to maximum delta increased and the width of the distribution curve broadened. CONCLUSION: Doubling sample volume will not double the chance of detecting slow growing organisms, but instead is predicted to improve detection by 25 percent or less.
引用
收藏
页码:430 / 433
页数:4
相关论文
共 50 条
  • [21] Evaluation of the blood volume effect on the diagnosis of bacteremia in automated blood culture systems
    Lin, Hsiu-Hsien
    Liu, Yen-Fang
    Tien, Ni
    Ho, Cheng-Mao
    Hsu, Ling-Nu
    Lu, Jang-Jih
    JOURNAL OF MICROBIOLOGY IMMUNOLOGY AND INFECTION, 2013, 46 (01) : 48 - 52
  • [22] Automated schizophrenia detection model using blood sample scattergram images and local binary pattern
    Tasci, Burak
    Tasci, Gulay
    Ayyildiz, Hakan
    Kamath, Aditya P.
    Barua, Prabal Datta
    Tuncer, Turker
    Dogan, Sengul
    Ciaccio, Edward J.
    Chakraborty, Subrata
    Acharya, U. Rajendra
    MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 83 (14) : 42735 - 42763
  • [23] Automated schizophrenia detection model using blood sample scattergram images and local binary pattern
    Burak Tasci
    Gulay Tasci
    Hakan Ayyildiz
    Aditya P. Kamath
    Prabal Datta Barua
    Turker Tuncer
    Sengul Dogan
    Edward J. Ciaccio
    Subrata Chakraborty
    U. Rajendra Acharya
    Multimedia Tools and Applications, 2024, 83 : 42735 - 42763
  • [24] Delayed insertion of blood culture bottles into automated continuously monitoring blood culture systems increases the time from blood sample collection to the detection of microorganisms in bacteremic patients
    Saito, Takashi
    Iinuma, Yoshitsugu
    Takakura, Shunji
    Nagao, Miki
    Matsushima, Aki
    Shirano, Michinori
    Ichiyama, Satoshi
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2009, 15 (01) : 49 - 53
  • [25] The Development and Evaluation of Blood Volume Measuring System for Blood Culture Quality Improvement
    Shim, Hun
    Kim, Kab Seung
    Uh, Young
    Seo, Dong Min
    Kim, Hyo Youl
    Yoon, Young Ro
    JOURNAL OF TESTING AND EVALUATION, 2012, 40 (04) : 655 - 660
  • [26] COMPARATIVE STUDY ON CONVENTIONAL BLOOD CULTURE AND AUTOMATED BLOOD CULTURE (BACTEC 9050) IN THE EARLY DETECTION OF BACTERIAL ISOLATES IN TERTIARY CARE HOSPITAL OF KUMAUN REGION
    Anjum, Nishat
    Umesh
    Rawat, Vinita
    Kumar, Mukesh
    Deopa, Mohan S.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (20): : 1647 - 1650
  • [27] URINE CULTURE TRANSPORT TUBES - EFFECT OF SAMPLE VOLUME ON BACTERIAL TOXICITY OF THE PRESERVATIVE
    NICKANDER, KK
    SHANHOLTZER, CJ
    PETERSON, LR
    JOURNAL OF CLINICAL MICROBIOLOGY, 1982, 15 (04) : 593 - 595
  • [28] Bacterial detection in platelet concentrates: A comparison between urine strips and culture
    Amorim, L
    Lopes, MEED
    Oliveira, JF
    Mello, C
    Santos, E
    Azevedo, I
    TRANSFUSION, 2004, 44 (09) : 48A - 48A
  • [29] Validation of an automatic culture system for detection of bacterial contamination in platelet concentrates
    Fayed, R
    Taylor, C
    Linauts, S
    TRANSFUSION, 2003, 43 (09) : 50A - 50A
  • [30] BacT/Alert automated culture and late sampling: an alternative option to rapid detection methods to detect bacterial contamination of platelet concentrates?
    Vollmer, T.
    Knabbe, C.
    Dreier, J.
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2017, 44 : 45 - 45