A closed-form expression for computing the sensitivity in second-order bilinear calibration

被引:65
|
作者
Olivieri, Alejandro C.
Faber, Nicolaas M.
机构
[1] Univ Nacl Rosario, Dept Quim Anal, Fac Ciencias Bioquim & Farmaceut, RA-2000 Rosario, Argentina
[2] Chemometry Consultancy, NL-6717 VD Ede, Netherlands
关键词
second-order bilinear calibration; sensitivity; net analyte signal; parallel factor analysis; bilinear least-squares;
D O I
10.1002/cem.964
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A general expression is derived for estimating the sensitivity of second-order bilinear calibration models, particularly parallel factor analysis (PARAFAC) and bilinear least-squares (BLLS), whether the second-order advantage is required or not. In the latter case, the sensitivity is correctly estimated either if the advantage is achieved by processing the unknown sample together with the calibration set (PARAFAC), or by post-calibration residual bilinearization (BLLS). The expression includes, as special cases, the sensitivity expressions already discussed by Messick, Kalivas and Lang (MKL) and by Ho, Christian and Davidson (HCD). The former one is the maximum achievable sensitivity in a given calibration situation, where all components are present in the calibration set of samples. The latter approach gives the lowest possible sensitivity, corresponding to only calibrating the analyte of interest, leaving the remaining components as uncalibrated constituents of the unknown sample. In intermediate situations, that is more than one calibrated analyte and presence of unexpected components in the unknown sample, only the present approach is able to provide a satisfactory sensitivity parameter, in close agreement with previously described Monte Carlo numerical simulations. Copyright (C) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:583 / 592
页数:10
相关论文
共 50 条
  • [41] On a class of systems of rational second-order difference equations solvable in closed form
    Stevic, Stevo
    MATHEMATICAL METHODS IN THE APPLIED SCIENCES, 2020, 43 (03) : 1001 - 1016
  • [42] Closed characteristics of second-order Lagrangians
    Kalies, WD
    Vandervorst, RCAM
    PROCEEDINGS OF THE ROYAL SOCIETY OF EDINBURGH SECTION A-MATHEMATICS, 2004, 134 : 143 - 158
  • [43] A closed form solution to L2-Sensitivity minimization of second-order state-space digital filters
    Yamaki, Shunsuke
    Abe, Masahide
    Kawamata, Masayuki
    2006 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, PROCEEDINGS, 2006, : 5223 - +
  • [44] A closed form solution to L2-sensitivity minimization of second-order state-space digital filters
    Yamaki, Shunsuke
    Abe, Masahide
    Kawamata, Masayuki
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2008, E91A (05) : 1268 - 1273
  • [45] Tensorial calibration: II. Second-order calibration
    Sanchez, Eugenio
    Kowalski, Bruce R.
    Journal of Chemometrics, 1988, 2 (04) : 265 - 280
  • [46] A CLOSED-FORM EXPRESSION FOR THE PROBABILITY OF CHECKSUM VIOLATION
    CHEN, SCT
    FANG, GS
    IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1980, 10 (07): : 407 - 410
  • [47] On stationarity and second-order properties of bilinear random fields
    Bibi A.
    Kimouche K.
    Statistical Inference for Stochastic Processes, 2014, 17 (3) : 221 - 244
  • [48] Explicit closed-form expression for eigenfunction norms
    Lockshin, JL
    APPLIED MATHEMATICS LETTERS, 2001, 14 (05) : 553 - 555
  • [49] On the closed-form expression of Carson's integral
    Department of Mechanical Engineering, University of Western, Macedonia, Kozani, Greece
    Period. polytech., Electr. eng. comput. sci., 1 (26-29):
  • [50] Closed-form calibration of the Gantry-Tau parallel robot
    Andreff, Nicolas
    Dressler, Isolde
    2008 IEEE/RSJ INTERNATIONAL CONFERENCE ON ROBOTS AND INTELLIGENT SYSTEMS, VOLS 1-3, CONFERENCE PROCEEDINGS, 2008, : 993 - 998