Small-Signal Stability Analysis and Current Control Reference Optimization Algorithm of DFIG-Based WT During Asymmetric Grid Faults

被引:19
|
作者
Fang, Xin [1 ]
Yao, Jun [1 ]
Liu, Ruikuo [2 ]
Zhao, Yang [1 ]
Sun, Peng [1 ]
Huang, Sen [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Sch Elect Engn, Chongqing 400044, Peoples R China
[2] China Three Gorges Corp, Inst Sci & Technol, Beijing 100038, Peoples R China
基金
中国国家自然科学基金;
关键词
Doubly fed induction generators; Power system stability; Phase locked loops; Power grids; Stability criteria; Couplings; Mathematical model; Asymmetric grid faults; doubly fed induction generator (DFIG); optimal current control reference algorithm; phase-locked loop (PLL); small-signal stability;
D O I
10.1109/TPEL.2020.3042514
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The stability issues of weak grid-connected doubly fed induction generator (DFIG) based wind turbines during asymmetric grid faults become very acute. In this article, a small-signal state-space model was established to deal with the stability problems of the DFIG system during asymmetric grid faults. Based on the model, the interaction mechanism between the power grid and the DFIG system during asymmetric faults is described and the modal analysis is performed. The analysis results show that the dominant unstable poles of the system are mainly affected by the phase-locked loop (PLL). Then, according to the vector relationships of voltages and currents, the effect of positive-sequence (PS) and negative-sequence (NS) d-axis currents on the PLL output angle is analyzed. It is pointed out that the system stability can be effectively improved by injecting reasonable d-axis components of PS and NS currents into the power grid during faults. Furthermore, considering the current capacity limitation of DFIG, a novel PS and NS current control reference optimization algorithm is proposed, which can suppress the oscillation of the system. Finally, the correctness of the theoretical analysis and the effectiveness of the proposed control strategy are validated by the simulation and experiments.
引用
收藏
页码:7750 / 7768
页数:19
相关论文
共 50 条
  • [41] Small-signal stability analysis of micro-grid with inverters employing droop control
    Xu, Qing-Shan
    Sun, Yin
    Ding, Mao-Sheng
    Li, Qiang
    Xin, Jian-Bo
    Xu, Qing-Qiang
    Xu, Q.-S. (xuqingshan@seu.edu.cn), 2013, South China University of Technology (41): : 56 - 62
  • [42] Comparative Analysis of Control Strategies for DFIG Based Wind System under Small Grid Faults
    Skander-Mustapha, S.
    Jebali-Ben Ghorbal, M.
    Arbi, J.
    Slama-Belkhodja, I.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2009, 4 (06): : 1273 - 1282
  • [43] Small-Signal Stability Improvement of Grid Integrated DFIG and SOFC System with SSSC-POD Using Coordinated Optimization Approach
    He, Ping
    Jin, Haoran
    Fang, Qiyuan
    Qi, Pan
    Gong, Zhijie
    Ji, Yuqi
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2022, 15 (06) : 485 - 501
  • [44] Mechanism Analysis of the Required Rotor Current and Voltage for DFIG-Based WTs to Ride-Through Severe Symmetrical Grid Faults
    Zou, Xudong
    Zhu, Donghai
    Hu, Jiabing
    Zhou, Shiying
    Kang, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (09) : 7300 - 7304
  • [45] Analysis of Small-signal Stability for Flexible DC Grid Based on Virtual Damping Index
    Fu Q.
    Du W.
    Wang H.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (11): : 111 - 120
  • [46] Harmonic Sequence Component Model-Based Small-Signal Stability Analysis in Synchronous Machines during Asymmetrical Faults
    Zevallos, Oscar C.
    Landera, Yandi A. Gallego
    Viltre, Lesyani Leon
    Carrasco, Jaime Addin Rohten
    ENERGIES, 2024, 17 (15)
  • [47] Analysis and Impacts of Implementing Droop Control in DFIG-Based Wind Turbines on Microgrid/Weak-Grid Stability
    Arani, Mohammadreza F. M.
    Mohamed, Yasser Abdel-Rady I.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (01) : 385 - 396
  • [48] Hybrid Power Synchronization Control Strategy of DFIG-based Wind Turbines and Its Stability Analysis Under Weak Grid
    Li M.
    Xie Z.
    Gao X.
    Yang S.
    Zhang X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (21): : 8388 - 8399
  • [49] Model order reduction analysis of DFIG integration on the power system small-signal stability considering the virtual inertia control
    Ma, Jing
    Song, Zhanxiang
    Zhang, Yongxin
    Shen, Yaqi
    Thorp, James S.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (16) : 4087 - 4095
  • [50] Modeling, Analysis, and Design for Small-Signal Stability in Sequence-Decomposed Grid-Forming Control
    Awal, M. A.
    Cen, Siye
    Rachi, Md Rifat Kaisar
    Yu, Hui
    Schroeder, Stefan
    Husain, Iqbal
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (01) : 865 - 875