Small-Signal Stability Analysis and Current Control Reference Optimization Algorithm of DFIG-Based WT During Asymmetric Grid Faults

被引:19
|
作者
Fang, Xin [1 ]
Yao, Jun [1 ]
Liu, Ruikuo [2 ]
Zhao, Yang [1 ]
Sun, Peng [1 ]
Huang, Sen [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Sch Elect Engn, Chongqing 400044, Peoples R China
[2] China Three Gorges Corp, Inst Sci & Technol, Beijing 100038, Peoples R China
基金
中国国家自然科学基金;
关键词
Doubly fed induction generators; Power system stability; Phase locked loops; Power grids; Stability criteria; Couplings; Mathematical model; Asymmetric grid faults; doubly fed induction generator (DFIG); optimal current control reference algorithm; phase-locked loop (PLL); small-signal stability;
D O I
10.1109/TPEL.2020.3042514
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The stability issues of weak grid-connected doubly fed induction generator (DFIG) based wind turbines during asymmetric grid faults become very acute. In this article, a small-signal state-space model was established to deal with the stability problems of the DFIG system during asymmetric grid faults. Based on the model, the interaction mechanism between the power grid and the DFIG system during asymmetric faults is described and the modal analysis is performed. The analysis results show that the dominant unstable poles of the system are mainly affected by the phase-locked loop (PLL). Then, according to the vector relationships of voltages and currents, the effect of positive-sequence (PS) and negative-sequence (NS) d-axis currents on the PLL output angle is analyzed. It is pointed out that the system stability can be effectively improved by injecting reasonable d-axis components of PS and NS currents into the power grid during faults. Furthermore, considering the current capacity limitation of DFIG, a novel PS and NS current control reference optimization algorithm is proposed, which can suppress the oscillation of the system. Finally, the correctness of the theoretical analysis and the effectiveness of the proposed control strategy are validated by the simulation and experiments.
引用
收藏
页码:7750 / 7768
页数:19
相关论文
共 50 条
  • [21] Transient Stability Analysis and Enhancement of DFIG-Based Wind Turbine With Demagnetization Control During Grid Fault
    Ma, Yumei
    Zhu, Donghai
    Zhu, Haipeng
    Hu, Jiabing
    Zou, Xudong
    Kang, Yong
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2025, 61 (01) : 1031 - 1042
  • [22] Stability Assessment and Enhanced Control of DFIG-Based WTs During Weak AC Grid
    Li, Zhi
    Xu, Hailiang
    Wang, Zhongxing
    Yan, Qingzeng
    IEEE ACCESS, 2022, 10 : 41371 - 41380
  • [23] Synchronization Instability Mechanism and Damping Enhancement Control for DFIG-Based Wind Turbine During Grid Faults
    Yang, Yihang
    Zhu, Donghai
    Zhou, Dangsheng
    Zou, Xudong
    Hu, Jiabing
    Kang, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (10) : 12104 - 12115
  • [24] Output control of DFIG-based wind power generation for improving transient stability and small signal stability
    Adachi T.
    Yokoyama A.
    Adachi, Tomohiro (t_adachi@syl.t.u-tokyo.ac.jp), 2017, Institute of Electrical Engineers of Japan (137) : 285 - 296
  • [25] Integration of automatic voltage regulator and power system stabilizer: small-signal stability in DFIG-based wind farms
    Essallah, Sirine
    Bouallegue, Adel
    Khedher, Adel
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2019, 7 (05) : 1115 - 1128
  • [26] Integration of automatic voltage regulator and power system stabilizer: small-signal stability in DFIG-based wind farms
    Sirine ESSALLAH
    Adel BOUALLEGUE
    Adel KHEDHER
    Journal of Modern Power Systems and Clean Energy, 2019, 7 (05) : 1115 - 1128
  • [27] Rotor current transient analysis of DFIG-based wind turbines during symmetrical voltage faults
    Ling, Yu
    Cai, Xu
    Wang, Ningbo
    ENERGY CONVERSION AND MANAGEMENT, 2013, 76 : 910 - 917
  • [28] Transient Stability Analysis and Improved Control Strategy for DC-Link Voltage of DFIG-Based WT During LVRT
    Chen, Shiyue
    Yao, Jun
    Pei, Jinxin
    Liu, Yuan
    Liu, Ruikuo
    Huang, Sen
    Chen, Zhaoyang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (02) : 880 - 891
  • [29] Transient Characteristics and Quantitative Analysis of Electromotive Force for DFIG-based Wind Turbines during Grid Faults
    Ma, Yumei
    Zhu, Donghai
    Zou, Xudong
    Kang, Yong
    Guerrero, Josep M.
    CHINESE JOURNAL OF ELECTRICAL ENGINEERING, 2022, 8 (02): : 3 - 12
  • [30] Small-signal modeling of MMC based DC grid and analysis of the impact of DC reactors on the small-signal stability
    Lu, Xiaojun
    Xiang, Wang
    Lin, Weixing
    Wen, Jinyu
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 101 : 25 - 37