Virtual patient 3D dose reconstruction using in air EPID measurements and a back-projection algorithm for IMRT and VMAT treatments

被引:37
|
作者
Olaciregui-Ruiz, Igor [1 ]
Rozendaal, Roel [1 ]
van Oers, Rene F. M. [1 ]
Mijnheer, Ben [1 ]
Mans, Anton [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
关键词
EPID dosimetry; Pre-treatment; In vivo; Verification; IMRT; VMAT; PRETREATMENT VERIFICATION; PASSING RATES; GAMMA INDEX; DOSIMETRY; QA; THERAPY;
D O I
10.1016/j.ejmp.2017.04.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: At our institute, a transit back-projection algorithm is used clinically to reconstruct in vivo patient and in phantom 3D dose distributions using EPID measurements behind a patient or a polystyrene slab phantom, respectively. In this study, an extension to this algorithm is presented whereby in air EPID measurements are used in combination with CT data to reconstruct 'virtual' 3D dose distributions. By combining virtual and in vivo patient verification data for the same treatment, patient-related errors can be separated from machine, planning and model errors. Methods and materials: The virtual back-projection algorithm is described and verified against the transit algorithm with measurements made behind a slab phantom, against dose measurements made with an ionization chamber and with the OCTAVIUS 4D system, as well as against TPS patient data. Virtual and in vivo patient dose verification results are also compared. Results: Virtual dose reconstructions agree within 1% with ionization chamber measurements. The average c-pass rate values (3% global dose/3 mm) in the 3D dose comparison with the OCTAVIUS 4D system and the TPS patient data are 98.5 +/- 1.9%(1SD) and 97.1 +/- 2.9%(1SD), respectively. For virtual patient dose reconstructions, the differences with the TPS in median dose to the PTV remain within 4%. Conclusions: Virtual patient dose reconstruction makes pre-treatment verification based on deviations of DVH parameters feasible and eliminates the need for phantom positioning and re-planning. Virtual patient dose reconstructions have additional value in the inspection of in vivo deviations, particularly in situations where CBCT data is not available (or not conclusive). (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [31] 3D "IN VIVO" DOSE VERIFICATION OF IMRT TREATMENTS USING A TRANSMISSION DETECTOR
    Ostinelli, A.
    Monti, A. F.
    Gelosa, S.
    Berlusconi, C.
    Scandolaro, L.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S229 - S230
  • [32] 3D Reconstruction from Adaptive Matrix Microphone Array Signals using Back Projection Algorithm
    Mizutani, Kyohei
    Sugimoto, Masanori
    Hashizume, Hiromichi
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 971 - 974
  • [33] 3D Forward and Back-Projection for X-Ray CT Using Separable Footprints
    Long, Yong
    Fessler, Jeffrey A.
    Balter, James M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (11) : 1839 - 1850
  • [34] A Method of 3D Dose Reconstruction Using MapCHECK Measurement for IMRT QA
    Kim, S.
    Barnett, E.
    Gallamore, M.
    Yeung, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [35] Independent Three-Dimensional (3D) Dose Verification of VMAT/SBRT Using EPID and Cloud Computing
    Ding, A.
    Han, B.
    Bush, K.
    Wang, L.
    Xing, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3447 - 3447
  • [36] Cardiac image reconstruction on a 16-slice CT scanner using a retrospectively ECG-gated, multi-cycle 3D back-projection algorithm
    Shechter, G
    Naveh, G
    Altman, A
    Proksa, R
    Grass, M
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1820 - 1828
  • [37] 3D in vivo dose verification of an entire IMRT treatment using an EPID and Cone-beam CT
    McDermott, L.
    Wending, M.
    Mans, A.
    de Jong, R.
    Sonke, J.
    van Herk, M.
    Mijnheer, B.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S98 - S98
  • [38] Rapid filtered back-projection algorithm in 2D ionospheric radio tomography using satellite-to-satellite measurements
    Nikolaev, Petr
    Filonin, Oleg
    Belokonov, Igor
    ADVANCES IN SPACE RESEARCH, 2021, 68 (10) : 4167 - 4188
  • [39] DOWNWARD LOOKING SPARSE LINEAR ARRAY 3D SAR IMAGING ALGORITHM BASED ON BACK-PROJECTION AND CONVEX OPTIMIZATION
    Bao Qian
    Peng Xueming
    Wang Yanping
    Tan Weixian
    Hong Wen
    JournalofElectronics(China), 2014, 31 (04) : 298 - 309
  • [40] Modified weighted back-projection algorithm (MWBP) for 3D electrical impedance mammography systems with the planar electrode array
    Khalighi, Mohammad
    Mikaeili, Mohammad
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (06):