Inductance effect of passive electromagnetic dampers on building-damper system subjected to near-fault earthquakes

被引:7
|
作者
Guo, Wei [1 ,2 ]
Wu, Xiaoli [1 ,2 ]
Wei, Xinna [1 ,3 ]
Cui, Yao [4 ]
Bu, Dan [5 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha, Hunan, Peoples R China
[2] Natl Engn Lab High Speed Railway Construct, Changsha, Hunan, Peoples R China
[3] Tongji Univ, Coll Civil Engn, Shanghai, Peoples R China
[4] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Liaoning, Peoples R China
[5] Hunan Architectural Design Inst, Changsha, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
client-server technology; damping density; inductance effect; near-fault earthquake; parameter optimization; passive electromagnetic damper; SEISMIC PERFORMANCE; GROUND MOTIONS; ENERGY; FEASIBILITY; CABLE;
D O I
10.1177/1369433219870579
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The passive electromagnetic damper was commonly simplified into the linear viscous model in numerical analysis, while this simplification may produce large error when the damper inductance is obvious. In this article, an optimal passive electromagnetic damper with good performance and economy characteristic is proposed by parameter optimization, where the damping density is set as the optimization objective. The hysteresis behavior of the passive electromagnetic damper is verified, and by neglecting the inductance effect, the passive electromagnetic damper can be simplified into the linear viscous model in some cases, but actually the inductance effect is obvious under the high-frequency excitation. Subsequently, the effect of inductance on seismic performance of building damper system under the near-fault earthquake is investigated by comparing the simplified linear viscous model and the accurate passive electromagnetic model. The passive electromagnetic damper was supplemented in a 9-story building, and the analysis of the accurate passive electromagnetic model was carried out by the co-simulation of MATLAB and OpenSees based on the client-server technology. It concludes that the inductance effect is obvious and causes large error when the building damper system is subjected to the near-fault earthquake, and the energy dissipation performance described by the linear viscous model is overestimated.
引用
收藏
页码:320 / 333
页数:14
相关论文
共 50 条
  • [31] Seismic mitigation performance of structures with viscous dampers under near-fault pulse-type earthquakes
    Hu, Gaoxing
    Wang, Yanan
    Huang, Wei
    Li, Bin
    Luo, Bin
    Engineering Structures, 2021, 203
  • [32] Simulation and analysis of a vertically irregular building subjected to near-fault ground motions
    Lin, Jui-Liang
    Chen, Wen-Hui
    Hsiao, Fu-Pei
    Weng, Yuan-Tao
    Shen, Wen-Cheng
    Weng, Pu-Wen
    Li, Yi-An
    Chao, Shu-Hsien
    EARTHQUAKE SPECTRA, 2020, 36 (03) : 1485 - 1516
  • [33] Seismic mitigation performance of structures with viscous dampers under near-fault pulse-type earthquakes
    Hu, Gaoxing
    Wang, Yanan
    Huang, Wei
    Li, Bin
    Luo, Bin
    ENGINEERING STRUCTURES, 2020, 203
  • [34] Effect of near-fault earthquakes on North American nuclear design spectra
    Galal, K.
    Ghobarah, A.
    NUCLEAR ENGINEERING AND DESIGN, 2006, 236 (18) : 1928 - 1936
  • [35] Effect of record scaling on the behavior of reinforced concrete core-wall buildings subjected to near-fault and far-fault earthquakes
    Beiraghi, H.
    Kheyroddin, A.
    Kafi, M. A.
    SCIENTIA IRANICA, 2017, 24 (03) : 884 - 899
  • [36] Performance of Bridges Isolated with Sliding-Lead Rubber Bearings Subjected to Near-Fault Earthquakes
    Zheng, Wenzhi
    Wang, Hao
    Hao, Hong
    Bi, Kaiming
    Shen, Huijun
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (02)
  • [37] Vibration Absorber System for Adjacent Structures Subjected to Near-Fault Excitations
    Bekdas, Gebrail
    Nigdeli, Sinan Melih
    INTERNATIONAL CONFERENCE OF NUMERICAL ANALYSIS AND APPLIED MATHEMATICS (ICNAAM 2017), 2018, 1978
  • [38] Structural control of RC buildings subjected to near-fault ground motions in terms of tuned mass dampers
    Naderpour, H.
    Kiani, A.
    Kheyroddin, A.
    SCIENTIA IRANICA, 2020, 27 (01) : 122 - 133
  • [39] The effect of near-fault directivity on building seismic collapse risk
    Champion, Casey
    Liel, Abbie
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (10): : 1391 - 1409
  • [40] Base-isolated building with high-damping spring system subjected to near fault earthquakes
    Eduardo Tornello, Miguel
    Sarrazin, Mauricio
    EARTHQUAKES AND STRUCTURES, 2012, 3 (3-4) : 315 - 340