Inductance effect of passive electromagnetic dampers on building-damper system subjected to near-fault earthquakes

被引:7
|
作者
Guo, Wei [1 ,2 ]
Wu, Xiaoli [1 ,2 ]
Wei, Xinna [1 ,3 ]
Cui, Yao [4 ]
Bu, Dan [5 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha, Hunan, Peoples R China
[2] Natl Engn Lab High Speed Railway Construct, Changsha, Hunan, Peoples R China
[3] Tongji Univ, Coll Civil Engn, Shanghai, Peoples R China
[4] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Liaoning, Peoples R China
[5] Hunan Architectural Design Inst, Changsha, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
client-server technology; damping density; inductance effect; near-fault earthquake; parameter optimization; passive electromagnetic damper; SEISMIC PERFORMANCE; GROUND MOTIONS; ENERGY; FEASIBILITY; CABLE;
D O I
10.1177/1369433219870579
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The passive electromagnetic damper was commonly simplified into the linear viscous model in numerical analysis, while this simplification may produce large error when the damper inductance is obvious. In this article, an optimal passive electromagnetic damper with good performance and economy characteristic is proposed by parameter optimization, where the damping density is set as the optimization objective. The hysteresis behavior of the passive electromagnetic damper is verified, and by neglecting the inductance effect, the passive electromagnetic damper can be simplified into the linear viscous model in some cases, but actually the inductance effect is obvious under the high-frequency excitation. Subsequently, the effect of inductance on seismic performance of building damper system under the near-fault earthquake is investigated by comparing the simplified linear viscous model and the accurate passive electromagnetic model. The passive electromagnetic damper was supplemented in a 9-story building, and the analysis of the accurate passive electromagnetic model was carried out by the co-simulation of MATLAB and OpenSees based on the client-server technology. It concludes that the inductance effect is obvious and causes large error when the building damper system is subjected to the near-fault earthquake, and the energy dissipation performance described by the linear viscous model is overestimated.
引用
收藏
页码:320 / 333
页数:14
相关论文
共 50 条
  • [11] Behavior factors for nonlinear structures subjected to multiple near-fault earthquakes
    Hatzigeorgiou, G. D.
    COMPUTERS & STRUCTURES, 2010, 88 (5-6) : 309 - 321
  • [12] Residual drift spectra for RC bridge columns subjected to near-fault earthquakes
    Seyed Ardakani, S. M.
    Saiidi, M. Saiid
    Somerville, Paul
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2021, 20 (01) : 193 - 211
  • [13] Residual drift spectra for RC bridge columns subjected to near-fault earthquakes
    S.M.Seyed Ardakani
    M.Saiid Saiidi
    Paul Somerville
    EarthquakeEngineeringandEngineeringVibration, 2021, 20 (01) : 193 - 211
  • [14] Experimental study on the effect of nonlinear viscous dampers on base-isolated structures under near-fault earthquakes
    Lyu, Qing
    Zhang, Haiqi
    Fu, Bo
    Zhu, Baijie
    Liu, Liangkun
    STRUCTURES, 2024, 61
  • [15] Residual drift spectra for RC bridge columns subjected to near-fault earthquakes
    S. M. Seyed Ardakani
    M. Saiid Saiidi
    Paul Somerville
    Earthquake Engineering and Engineering Vibration, 2021, 20 : 193 - 211
  • [16] Effect of near-fault earthquakes with forward directivity on telecommunication towers
    Mahmood Yahyai
    B. Rezayibana
    E. Mohammadrezapour
    Earthquake Engineering and Engineering Vibration, 2011, 10 : 211 - 218
  • [17] Effect of near-fault earthquakes with forward directivity on telecommunication towers
    Yahyai, M.
    Rezayibana, B.
    Mohammadrezapour, E.
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2011, 10 (02) : 211 - 218
  • [18] Effect of near-fault earthquakes with forward directivity on telecommunication towers
    M.Yahyai
    B.Rezayibana
    E.Mohammadrezapour
    EarthquakeEngineeringandEngineeringVibration, 2011, 10 (02) : 211 - 218
  • [19] Seismic Analysis of Adjacent Inelastic Structures Connected with Hysteretic Dampers under Near-Fault Earthquakes
    Huang, X.
    Zhu, H. P.
    Hu, Z. X.
    ADVANCES IN STRUCTURAL ENGINEERING, 2013, 16 (09) : 1487 - 1497
  • [20] Performance of viscous fluid dampers coupling adjacent inelastic structures under near-fault earthquakes
    Ge Dong-dong
    Zhu Hong-ping
    Zhang Jun-bing
    Chen Xiao-qiang
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2010, 17 (06): : 1336 - 1343