Inductance effect of passive electromagnetic dampers on building-damper system subjected to near-fault earthquakes

被引:7
|
作者
Guo, Wei [1 ,2 ]
Wu, Xiaoli [1 ,2 ]
Wei, Xinna [1 ,3 ]
Cui, Yao [4 ]
Bu, Dan [5 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha, Hunan, Peoples R China
[2] Natl Engn Lab High Speed Railway Construct, Changsha, Hunan, Peoples R China
[3] Tongji Univ, Coll Civil Engn, Shanghai, Peoples R China
[4] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Liaoning, Peoples R China
[5] Hunan Architectural Design Inst, Changsha, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
client-server technology; damping density; inductance effect; near-fault earthquake; parameter optimization; passive electromagnetic damper; SEISMIC PERFORMANCE; GROUND MOTIONS; ENERGY; FEASIBILITY; CABLE;
D O I
10.1177/1369433219870579
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The passive electromagnetic damper was commonly simplified into the linear viscous model in numerical analysis, while this simplification may produce large error when the damper inductance is obvious. In this article, an optimal passive electromagnetic damper with good performance and economy characteristic is proposed by parameter optimization, where the damping density is set as the optimization objective. The hysteresis behavior of the passive electromagnetic damper is verified, and by neglecting the inductance effect, the passive electromagnetic damper can be simplified into the linear viscous model in some cases, but actually the inductance effect is obvious under the high-frequency excitation. Subsequently, the effect of inductance on seismic performance of building damper system under the near-fault earthquake is investigated by comparing the simplified linear viscous model and the accurate passive electromagnetic model. The passive electromagnetic damper was supplemented in a 9-story building, and the analysis of the accurate passive electromagnetic model was carried out by the co-simulation of MATLAB and OpenSees based on the client-server technology. It concludes that the inductance effect is obvious and causes large error when the building damper system is subjected to the near-fault earthquake, and the energy dissipation performance described by the linear viscous model is overestimated.
引用
收藏
页码:320 / 333
页数:14
相关论文
共 50 条
  • [1] Seismic Performance Evaluation of Building-Damper System under Near-Fault Earthquake
    Wu, Xiaoli
    Guo, Wei
    Hu, Ping
    Bu, Dan
    Xie, Xu
    Hu, Yao
    SHOCK AND VIBRATION, 2020, 2020 (2020)
  • [2] Performance of structures with passive dampers subject to near-fault earthquakes
    He, WL
    Agrawal, AK
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 489 - 496
  • [3] THE INFLUENCE OF VISCOUS DAMPERS ON THE BETTER PERFORMANCE OF WATER PIPELINES SUBJECTED TO NEAR-FAULT EARTHQUAKES
    Shokouhi, Seyed Kazem Sadat
    Dolatshah, Azam
    Vosoughifar, Hamid Reza
    Rahnavard, Yousef
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE - 2013, VOL 8: SEISMIC ENGINEERING, 2014,
  • [4] Application of Smart Dampers for Prevention of Seismic Pounding in Isolated Structures Subjected to Near-fault Earthquakes
    Rayegani, Arash
    Nouri, Gholamreza
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (08) : 4069 - 4084
  • [5] SSI in steel frames subjected to near-fault earthquakes
    Minasidis, G.
    Hatzigeorgiou, G. D.
    Beskos, D. E.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2014, 66 : 56 - 68
  • [6] Performance of TMDs on nonlinear structures subjected to near-fault earthquakes
    Domizio, Martin
    Ambrosini, Daniel
    Curadelli, Oscar
    SMART STRUCTURES AND SYSTEMS, 2015, 16 (04) : 725 - 742
  • [7] OPTIMAL PLACEMENT OF VISCOUS DAMPERS IN THE WATER PIPELINE NETWORKS SUBJECTED TO NEAR-FAULT EARTHQUAKES USING GENETIC ALGORITHM
    Shokouhi, Seyed Kazem Sadat
    Dolatshah, Azam
    Vosoughifar, Hamid Reza
    Rahnavard, Yousef
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE - 2013, VOL 8: SEISMIC ENGINEERING, 2014,
  • [8] Semi-active fuzzy control for seismic response reduction of building frames using variable orifice dampers subjected to near-fault earthquakes
    Ghaffarzadeh, Hossein
    Dehrod, Ebrahim Alizadeh
    Talebian, Nima
    JOURNAL OF VIBRATION AND CONTROL, 2013, 19 (13) : 1980 - 1998
  • [9] Predictive control of smart isolation system for precision equipment subjected to near-fault earthquakes
    Lu, Lyan-Ywan
    Lin, Ging-Long
    ENGINEERING STRUCTURES, 2008, 30 (11) : 3045 - 3064
  • [10] The effect of near-fault earthquakes and wavelet-generated artificial near-fault earthquakes on the seismic behavior of rockfill dams
    Sun, Benbo
    Deng, Mingjiang
    Zhang, Sherong
    Wang, Chao
    Cui, Wei
    Du, Min
    Lai, Yishu
    STRUCTURES, 2023, 58