Assessment of Reproducibility of Laser Electrospray Mass Spectrometry using Electrospray Deposition of Analyte

被引:6
|
作者
Sistani, Habiballah
Karki, Santosh
Archer, Jieutonne J.
Shi, Fengjian
Levis, Robert J. [1 ]
机构
[1] Temple Univ, Dept Chem, Philadelphia, PA 19122 USA
基金
美国国家科学基金会;
关键词
Femtosecond laser vaporization; Electrospray deposition; Quantitative analysis; QUANTITATIVE-ANALYSIS; SAMPLE PREPARATION; IONIZATION; DESORPTION/IONIZATION; VAPORIZATION; MALDI; MACROMOLECULES; SUPPRESSION; MIXTURES; SURFACES;
D O I
10.1007/s13361-017-1622-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A nonresonant, femtosecond (fs) laser is employed to desorb samples of Victoria blue deposited on stainless steel or indium tin oxide (ITO) slides using either electrospray deposition (ESD) or dried droplet deposition. The use of ESD resulted in uniform films of Victoria blue whereas the dried droplet method resulted in the formation of a ring pattern of the dye. Laser electrospray mass spectrometry (LEMS) measurements of the ESD-prepared films on either substrate were similar and revealed lower average relative standard deviations for measurements within-film (20.9%) and between-films (8.7%) in comparison to dried droplet (75.5% and 40.2%, respectively). The mass spectral response for ESD samples on both substrates was linear (R-2 > 0.99), enabling quantitative measurements over the selected range of 7.0 x 10(-11) to 2.8 x 10(-9) mol, as opposed to the dried droplet samples where quantitation was not possible (R-2 = 0.56). The limit of detection was measured to be 210 fmol.
引用
收藏
页码:880 / 886
页数:7
相关论文
共 50 条
  • [21] Analyte migration electrospray ionization for rapid analysis of complex samples with small volume using mass spectrometry
    Wang, Qian
    Zhong, Hanbin
    Zheng, Yajun
    Zhang, Sichun
    Liu, Xiaoning
    Zhang, Xinrong
    Zhang, Xiaoling
    Zhang, Zhiping
    ANALYST, 2014, 139 (22) : 5678 - 5681
  • [22] Increasing Protein Charge State When Using Laser Electrospray Mass Spectrometry
    Karki, Santosh
    Flanigan, Paul M.
    Perez, Johnny J.
    Archer, Jieutonne J.
    Levis, Robert J.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (05) : 706 - 715
  • [23] Quantitative Measurements of Small Molecule Mixtures Using Laser Electrospray Mass Spectrometry
    Flanigan, Paul M.
    Perez, Johnny J.
    Karki, Santosh
    Levis, Robert J.
    ANALYTICAL CHEMISTRY, 2013, 85 (07) : 3629 - 3637
  • [25] Microdevices for electrospray mass spectrometry
    Foret, F
    Liu, H
    Zhang, B
    Felten, C
    Karger, BL
    MICRO TOTAL ANALYSIS SYSTEMS '98, 2000, : 35 - 38
  • [26] Electrospray ionization mass spectrometry
    Banks, JF
    Whitehouse, CM
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT A, 1996, 270 : 486 - 519
  • [27] Electrospray mass spectrometry of phospholipids
    Pulfer, M
    Murphy, RC
    MASS SPECTROMETRY REVIEWS, 2003, 22 (05) : 332 - 364
  • [28] Electrospray Ionization for Mass Spectrometry
    不详
    LC GC NORTH AMERICA, 2012, 30 (02) : 182 - 182
  • [29] Pulsed electrospray for mass spectrometry
    Lu, Y
    Zhou, F
    Shui, WQ
    Bian, LP
    Yang, PY
    ANALYTICAL CHEMISTRY, 2001, 73 (19) : 4748 - 4753
  • [30] Strategies for determination of insulin with tandem electrospray mass spectrometry:: implications for other analyte proteins?
    Fierens, C
    Stöckl, D
    Thienpont, LM
    De Leenheer, AP
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (16) : 1433 - 1441