Timing of changes in interstitial and blood glucose measured with a continuous subcutaneous glucose sensor

被引:0
|
作者
Boyne, MS
Silver, DM
Kaplan, J
Saudek, CD
机构
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
398
引用
收藏
页码:A99 / A99
页数:1
相关论文
共 50 条
  • [1] Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    Boyne, MS
    Silver, DM
    Kaplan, J
    Saudek, CD
    DIABETES, 2003, 52 (11) : 2790 - 2794
  • [2] Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring
    Aussedat, B
    Dupire-Angel, M
    Gifford, R
    Klein, JC
    Wilson, GS
    Reach, G
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04): : E716 - E728
  • [3] Glycemia in blood, brain and subcutaneous tissue measured by a continuous glucose monitoring system
    M Zourek
    Z Jankovec
    P Hykova
    Critical Care, 15 (Suppl 1):
  • [4] Evaluation of conventional blood glucose monitoring as an indicator of integrated glucose values using a continuous subcutaneous sensor
    Zavalkoff, SR
    Polychronakos, C
    DIABETES CARE, 2002, 25 (09) : 1603 - 1606
  • [5] Is the Response of Continuous Glucose Monitors to Physiological Changes in Blood Glucose Levels Affected by Sensor Life?
    Iscoe, Katherine E.
    Davey, Raymond J.
    Fournier, Paul A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (02) : 135 - 142
  • [6] Physiological differences between interstitial glucose and blood glucose measured in human subjects
    Kulcu, E
    Tamada, JA
    Reach, G
    Potts, RO
    Lesho, MJ
    DIABETES CARE, 2003, 26 (08) : 2405 - 2409
  • [7] A MEMS SENSOR FOR CONTINUOUS MONITORING OF GLUCOSE IN SUBCUTANEOUS TISSUE
    Huang, X.
    Li, S.
    Schultz, J.
    Wang, Q.
    Lin, Q.
    IEEE 22ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2009), 2009, : 352 - 355
  • [8] Continuous glucose monitoring on the ICU using a subcutaneous sensor
    Punke, M. A.
    Decker, C.
    Wodack, K.
    Reuter, D. A.
    Kluge, S.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2015, 110 (05) : 360 - 363
  • [9] Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats
    Woderer, Stefanie
    Henninger, Nadja
    Garthe, Claus-Dieter
    Kloetzer, Hans Martin
    Hajnsek, Martin
    Kamecke, Ulrike
    Gretz, Norbert
    Kraenzlin, Bettina
    Pill, Johannes
    ANALYTICA CHIMICA ACTA, 2007, 581 (01) : 7 - 12
  • [10] Effect of recalibration on agreement between blood glucose and subcutaneous glucose sensor readings
    Silver, DM
    Boyne, MS
    Saudek, CD
    DIABETES, 2001, 50 : A131 - A131