Comparison of three methods of extravascular lung water volume measurement in patients after cardiac surgery

被引:5
|
作者
Maddison, Benjamin [1 ]
Wolff, Christopher [1 ]
Findlay, George [2 ]
Radermacher, Peter [3 ]
Hinds, Charles [1 ]
Pearse, Rupert M. [1 ]
机构
[1] Queen Marys Univ London, Royal London Hosp, Barts & London Sch Med & Dent, London E1 1BB, England
[2] Univ Wales Hosp, Intens Care Unit, Cardiff CF14 4XW, S Glam, Wales
[3] Univ Ulm Klinikum, Sekt Anasthesiol Pathophysiol & Verfahrensentwick, D-89081 Ulm, Germany
来源
CRITICAL CARE | 2009年 / 13卷 / 04期
关键词
CRITICALLY ILL PATIENTS; POSTMORTEM GRAVIMETRY; OUTPUT MEASUREMENT; THERMAL DILUTION; INDICATOR; SINGLE; THERMODILUTION; BLOOD; CIRCULATION; MANAGEMENT;
D O I
10.1186/cc7948
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Measurement of extravascular lung water (EVLW) by using the lithium-thermal (Li-thermal) and single-thermal indicator dilution methods was compared with the indocyanine green-thermal (ICG-thermal) method in humans. Methods Single-center observational study involving patients undergoing cardiac surgery with cardiopulmonary bypass. Paired measurements were taken 1, 2, 4, and 6 hours after surgery. Bland-Altman analysis was used to calculate bias and limits of agreement. Data are presented as mean (SD) or median (IQR). Results Seventeen patients were recruited (age, 69 years ( 54 to 87 years); Parsonnet score 10 (0 to 29)). Sixteen ICG-thermal measurements were excluded after blinded assessment because of poor-quality indicator dilution curves. EVLW volume as measured by the ICG-thermal technique was 4.6 (1.9) ml/kg, compared with 5.3 (1.4) ml/kg for the single-thermal method. Measurements taken with the Li-thermal method were clearly erroneous (-7.6 (7.4) ml/kg). In comparison with simultaneous measurements with the ICG-thermal method, single-thermal measurements had an acceptable degree of bias, but limits of agreement were poor (bias, -0.3 ml/kg (2.3)). Li-thermal measurements compared poorly with the ICG-thermal reference method (bias, 13.2 ml/kg (14.4)). Conclusions The principal finding of this study was that the prototype Li-thermal method did not provide reliable measurements of EVLW volume when compared with the ICG-thermal reference technique. Although minimal bias was associated with the single-thermal method, limits of agreement were approximately 45% of the normal value of EVLW volume. The Li-thermal method performed very poorly because of the overestimation of mean indicator transit time by using an external lithium ion electrode. These findings suggest that the assessment of lung water content by lithium-indicator dilution is not sufficiently reliable for clinical use in individual patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Measurement of cardiac output and extravascular lung water by transpulmonary thermodilution in postoperative monopulmonary transplantation
    Dinh, A. Tran
    Dufour, G.
    Piednoir, P.
    Augustin, P.
    Montravers, P.
    Desmard, M.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A47 - A47
  • [42] Influence of extravascular lung water on transpulmonary thermodilution-derived cardiac output measurement
    Thomas Pohl
    Jan Kozieras
    Samir G. Sakka
    Intensive Care Medicine, 2008, 34 : 533 - 537
  • [43] Influence of extravascular lung water on transpulmonary thermodilution-derived cardiac output measurement
    Pohl, Thomas
    Kozieras, Jan
    Sakka, Samir G.
    INTENSIVE CARE MEDICINE, 2008, 34 (03) : 533 - 537
  • [44] Extravascular lung water in ARDS patients
    Sakka, S. G.
    MINERVA ANESTESIOLOGICA, 2013, 79 (03) : 274 - 284
  • [45] The Role of Extravascular Lung Water Measurement in the Potential Lung Donor
    Venkateswaran, R. V.
    Patchell, V. B.
    Coote, J. H.
    Wilson, I. C.
    Mascaro, J. G.
    Thompson, R. D.
    Bonser, R. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S57 - S57
  • [46] Study of perioperative extravascular lung water and intrathoracic blood volume in patients undergoing CABG surgery with or without cardiopulmonary bypass
    El Azab, Samia Ragab
    Ghoneim, Sameh H.
    Abd Rabo, Mahmoud
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2014, 30 (04) : 417 - 422
  • [47] THE INFLUENCE OF EXTRACORPOREAL-CIRCULATION ON EXTRAVASCULAR LUNG WATER IN CORONARY SURGERY PATIENTS
    BOLDT, J
    VANBORMANN, B
    KLING, D
    SCHELD, HH
    HEMPELMANN, G
    THORACIC AND CARDIOVASCULAR SURGEON, 1986, 34 (02): : 110 - 115
  • [48] Utility of lung ultrasound for extravascular lung water volume estimation during cytoreductive surgery and hyperthermic intraperitoneal chemotherapy
    Mittal, Amit Kumar
    Jaipuria, Jiten
    Patel, Anil
    Bhatnagar, Vishal
    Chawla, Rajiv
    Singh, Shivendra
    INDIAN JOURNAL OF ANAESTHESIA, 2021, 65 (06) : 158 - 164
  • [49] EXTRAVASCULAR LUNG WATER ACCUMULATION IN PATIENTS FOLLOWING CORONARY-ARTERY SURGERY
    BYRICK, RJ
    KAY, JC
    NOBLE, WH
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1977, 24 (03) : 332 - 345
  • [50] EXTRAVASCULAR LUNG WATER INDEX IN PATIENTS DURING AND AFTER ELECTIVE BRAIN TUMOR SURGERY: A PROPOSAL FOR NORMAL VALUES
    Wolf, S.
    Riess, A.
    Landscheidt, J. F.
    Lumenta, C. B.
    Schuerer, L.
    Friederich, P.
    INTENSIVE CARE MEDICINE, 2010, 36 : S93 - S93