On-line detection of atmospheric formaldehyde by a conductometric biosensor

被引:21
|
作者
Vianello, Fabio
Boscolo-Chio, Raffaella
Signorini, Stefano
Rigo, Adelio
机构
[1] Univ Padua, Dept Biol Chem, I-35121 Padua, Italy
[2] ISPESL, Dipartimento Med Lavoro, Rome, Italy
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 22卷 / 06期
关键词
formaldehyde determination; conductometric biosensor; formaldehyde dehydrogenase; atmosphere pollution monitoring;
D O I
10.1016/j.bios.2006.03.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Atmospheric fomaldehyde (CH2O) was detected under continuous flow conditions by an on-line system comprising of a wet scrubber for a continuous transfer of the pollutant to an aqueous solution, a micro-reactor containing immobilized formaldehyde dehydrogenase (FDH) and a conductometric transducer. By this system atmospheric formaldehyde concentrations in the range 0.05-2 ppm were detected with a sensitivity of 20 mu S/ppm. In this concentration range the immobilized enzyme oxidized all the sampled formaldehyde molecules to formic acid, avoiding cumbersome calibration procedures. The operational stability of the biosensor was at least 3 months, working continuously 10h/day at room temperature. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:920 / 925
页数:6
相关论文
共 50 条
  • [41] On-line stBOD measurement and toxicity control of wastewaters with a respirographic biosensor
    Kong, Z
    Vaerewijck, M
    Verstraete, W
    ENVIRONMENTAL TECHNOLOGY, 1996, 17 (04) : 399 - 406
  • [42] A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor
    Thomas Charrier
    Cyrille Chapeau
    Loubna Bendria
    Pascal Picart
    Philippe Daniel
    Gérald Thouand
    Analytical and Bioanalytical Chemistry, 2011, 400 : 1061 - 1070
  • [43] Development of a normalized multi-sensors system for low cost on-line atmospheric pollution detection
    Al Barakeh, Zaher
    Breuil, Philippe
    Redon, Nathalie
    Pijolat, Christophe
    Locoge, Nadine
    Viricelle, Jean-Paul
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 1235 - 1243
  • [44] A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor
    Charrier, Thomas
    Chapeau, Cyrille
    Bendria, Loubna
    Picart, Pascal
    Daniel, Philippe
    Thouand, Gerald
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (04) : 1061 - 1070
  • [45] Validation of a conductometric bienzyme biosensor for the detection of proteins as marker of organic matter in river samples
    KHADRO Basma
    NAMOUR Philippe
    BESSUEILLE Franois
    LEONARD Didier
    JAFFREZICRENAULT Nicole
    Journal of Environmental Sciences, 2009, 21 (04) : 545 - 551
  • [46] Development of a Conductometric Sensor Based on Al,Ca-Doped ZnO for the Detection of Formaldehyde
    Crispi, Simona
    Neri, Giovanni
    SENSORS, 2022, 22 (19)
  • [47] Validation of a conductometric bienzyme biosensor for the detection of proteins as marker of organic matter in river samples
    Khadro, Basma
    Namour, Philippe
    Bessueille, Francois
    Leonard, Didier
    Jaffrezic-Renault, Nicole
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2009, 21 (04) : 545 - 551
  • [48] Validation of a conductometric bienzyme biosensor for the detection of proteins as marker of organic matter in river samples
    KHADRO Basma
    NAMOUR Philippe
    BESSUEILLE Franois
    LEONARD Didier
    JAFFREZIC-RENAULT Nicole
    Journal of Environmental Sciences, 2009, (04) : 545 - 551
  • [49] Direct detection of phenol using a new bacterial strain-based conductometric biosensor
    Kolahchi, Narjes
    Braiek, Mohamed
    Ebrahimipour, Gholamhossein
    Ranaei-Siadat, Seyed Omid
    Lagarde, Florence
    Jaffrezic-Renault, Nicole
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2018, 6 (01): : 478 - 484
  • [50] Flow injection analysis of L-lactate in milk and yoghurt by on-line microdialysis and amperometric detection at a disposable biosensor
    Palmisano, F
    Quinto, M
    Rizzi, R
    Zambonin, PG
    ANALYST, 2001, 126 (06) : 866 - 870