On-line detection of atmospheric formaldehyde by a conductometric biosensor

被引:21
|
作者
Vianello, Fabio
Boscolo-Chio, Raffaella
Signorini, Stefano
Rigo, Adelio
机构
[1] Univ Padua, Dept Biol Chem, I-35121 Padua, Italy
[2] ISPESL, Dipartimento Med Lavoro, Rome, Italy
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 22卷 / 06期
关键词
formaldehyde determination; conductometric biosensor; formaldehyde dehydrogenase; atmosphere pollution monitoring;
D O I
10.1016/j.bios.2006.03.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Atmospheric fomaldehyde (CH2O) was detected under continuous flow conditions by an on-line system comprising of a wet scrubber for a continuous transfer of the pollutant to an aqueous solution, a micro-reactor containing immobilized formaldehyde dehydrogenase (FDH) and a conductometric transducer. By this system atmospheric formaldehyde concentrations in the range 0.05-2 ppm were detected with a sensitivity of 20 mu S/ppm. In this concentration range the immobilized enzyme oxidized all the sampled formaldehyde molecules to formic acid, avoiding cumbersome calibration procedures. The operational stability of the biosensor was at least 3 months, working continuously 10h/day at room temperature. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:920 / 925
页数:6
相关论文
共 50 条
  • [31] On-line monitoring and fault detection
    Seem, JE
    House, JM
    Monroe, RH
    ASHRAE JOURNAL, 1999, 41 (07) : 21 - 26
  • [32] The on-line slag detection in the steelmaking
    Zahorszki, F
    Lyons, AR
    THERMOSENSE XXII, 2000, 4020 : 10 - 14
  • [33] An approach to on-line predictive detection
    Zhang, F
    Hellerstein, JL
    8TH INTERNATIONAL SYMPOSIUM ON MODELING, ANALYSIS AND SIMULATION OF COMPUTER AND TELECOMMUNICATION SYSTEMS, PROCEEDINGS, 2000, : 549 - 556
  • [34] Conductometric biosensor for arginine determination in pharmaceutics
    Soldatkina, O. V.
    Soldatkin, O. O.
    Velychko, T. P.
    Prilipko, V. O.
    Kuibida, M. A.
    Dzyadevych, S. V.
    BIOELECTROCHEMISTRY, 2018, 124 : 40 - 46
  • [35] On-line bacteriological detection in water
    Lopez-Roldan, Ramon
    Tusell, Pol
    Courtois, Sophie
    Luis Cortina, Jose
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 44 : 46 - 57
  • [36] Efficient on-line repetition detection
    Hong, Jin-Ju
    Chen, Gen-Huey
    THEORETICAL COMPUTER SCIENCE, 2008, 407 (1-3) : 554 - 563
  • [37] On-line detection of winding deformation
    Alpatov, M
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 113 - 116
  • [38] CONDUCTOMETRIC BIOSENSOR FOR DETERMINATION OF ORGANOPHOSPHORUS PESTICIDES
    DZYADEVICH, SV
    SOLDATKIN, AP
    SHULGA, AA
    STRIKHA, VI
    ELSKAYA, AV
    JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 49 (08) : 789 - 792
  • [39] Conductometric enzyme biosensor for patulin determination
    Soldatkin, O. O.
    Stepurska, K. V.
    Arkhypova, V. M.
    Soldatkin, A. P.
    El'skaya, A. V.
    Lagarde, F.
    Dzyadevych, S. V.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 : 1010 - 1015
  • [40] Biosensor for on-line monitoring of penicillin during its production by fermentation
    TranMinh, C
    Meier, H
    BIOSENSOR AND CHEMICAL SENSOR TECHNOLOGY: PROCESS MONITORING AND CONTROL, 1995, 613 : 110 - 115