A Novel electronic chain for high level neutron coincidence counters

被引:3
|
作者
Fazzi, A
Pirovano, C
Varoli, V
机构
[1] Politecnico di Milano, Dip. Ingegneria Nucleare, Milano 20133
关键词
D O I
10.1109/23.603710
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a counting chain (charge preamplifier, shaping amplifier and threshold discriminator) devoted to He-3 neutron detectors. The preamplifier adopts an innovative circuit with the gate of the input JFET floating and a DC feedback loop that stabilizes the output voltage acting on the input cascade second transistor. Static and dynamic analysis, including the effects of the detector bias network, is developed and reported. The shaping amplifier is a fifth-order quasi-gaussian OPAMP active filter that minimizes the number of components. Shaping time constants ranging from 1 mu s down to 100 ns are explored in order to maximize the count rate capability, maintaining nevertheless neutron discrimination. Experimental signals and spectra show that 100 ns shaping time is a lower limit for the usual He-3 proportional detector. Since this counting chain is characterized by single 5V supply operation, high counting rate, small size and low cost, it is well suited for high efficiency neutron well detectors where a large number (10 - 100) of counting tubes are used (High Level Neutron Coincidence Counter HLNCC).
引用
收藏
页码:557 / 562
页数:6
相关论文
共 50 条
  • [2] METHODOLOGY OF STANDARD CERTIFICATION FOR CALIBRATION OF NEUTRON COINCIDENCE COUNTERS
    KOSITSYN, VF
    KONYAEV, AE
    KOZHUKHOVSKAYA, SA
    KERNENERGIE, 1991, 34 (02): : 45 - 47
  • [3] ELECTRONIC COLLIMATION WITH FAST COINCIDENCE TECHNIQUE IN PROPORTIONAL COUNTERS
    MIZUHO, M
    YAMANAKA, T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1970, 7 (06): : 285 - &
  • [4] FAST NEUTRON SPECTROMETER WITH FAST COINCIDENCE TECHNIQUE IN PROPORTIONAL COUNTERS
    MIZUHO, M
    YAMANAKA, T
    NUCLEAR INSTRUMENTS & METHODS, 1971, 91 (01): : 57 - &
  • [5] A single-supply, high rate, small size and cheap electronic chain for He-3 neutron counters
    Boffa, A
    Fazzi, A
    Pirovano, C
    Varoli, V
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 934 - 937
  • [6] MEASUREMENT OF PARAMETERS OF NEUTRON FLUX IN A REACTOR BY MEANS OF ACTIVATION COINCIDENCE COUNTERS
    BIRYUKOV, EI
    KHRAMOV, NN
    SHIMANSK.NS
    SOVIET ATOMIC ENERGY-USSR, 1970, 28 (04): : 457 - &
  • [7] A comparison of Monte Carlo fission models for safeguards neutron coincidence counters
    Weinmann-Smith, R. K.
    Swinhoe, M. T.
    Trahan, A.
    Andrews, M. T.
    Menlove, H. O.
    Enqvist, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 903 : 99 - 108
  • [8] Electronic neutron sensor based on coincidence detection
    Barelaud, B
    Decossas, JL
    Mokhtari, F
    Vareille, JC
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D356 - D358
  • [9] SHIFT-REGISTER COINCIDENCE ELECTRONICS SYSTEM FOR THERMAL-NEUTRON COUNTERS
    SWANSEN, JE
    COLLINSWORTH, PR
    KRICK, MS
    NUCLEAR INSTRUMENTS & METHODS, 1980, 176 (03): : 555 - 565
  • [10] HIGH-LEVEL GAMMA TOLERANCE OF FISSION CHAMBER AND BORON-LINED NEUTRON COUNTERS
    JACKSON, CN
    HOITINK, NC
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (01): : 310 - &