New Fe(II) Ion-selective electrode based On N-Phenylaza-15-Crown-5 as neutral carrier in PVC matrix

被引:26
|
作者
Aghaie, M. [2 ]
Giahi, M. [1 ]
Aghaie, H. [3 ]
Arvand, M. [4 ]
Pournaghdy, M. [3 ]
Yavari, F. [1 ]
机构
[1] Islamic Azad Univ, Fac Sci, Lahijan Branch, Dept Chem, Lahijan, Iran
[2] Islamic Azad Univ, N Tehran Branch, Dept Chem, Tehran, Iran
[3] Islamic Azad Univ, Dept Chem, Tehran, Iran
[4] Univ Guilan, Fac Sci, Dept Chem, Rasht, Iran
关键词
Fe(II)-selective electrode; Stability constant; PVC membrane; N-phenylaza-15-crown-5; BULK OPTODES; CROWN-ETHER; MEMBRANE; IONOPHORES; SENSORS; COEFFICIENTS; CONSTANTS;
D O I
10.1016/j.desal.2008.10.007
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Fe(II) ions was prepared using N-phenylaza-15-crown-5 (NPA15C5) as a suitable neutral carrier. The sensor exhibits a Nernstian response for Fe(II) ions over a wide concentration range (1.0 x 10(-2) to 1.0 x 10(-6) M) with a slope of 29.2 +/- 0.6 mV per decade. It has a response time of <15 s and can be used for at least 2 months without any measurable divergence in potential. The proposed sensor shows a fairly good discriminating ability towards Fe(2+) ion in comparison with some hard and soft metal ions. The isothermal temperature coefficient of this electrode amounted to 0.0017 V/degrees C. The stability constant (log K(s)) of the Fe(II)-NPA15C5 complex was determined at 25 degrees C by potentiometric titration in mixed aqueous solution. The results show that this electrode can be used in ethanol and dioxane media up to 20% and 5% (v/v) concentration, respectively, without interference. The electrode was used for direct determination of Fe(2+) in the ferrous sulfate syrup.
引用
收藏
页码:346 / 354
页数:9
相关论文
共 50 条
  • [21] NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE FOR INTRACELLULAR MAGNESIUM ACTIVITY STUDIES
    LANTER, F
    ERNE, D
    AMMANN, D
    SIMON, W
    ANALYTICAL CHEMISTRY, 1980, 52 (14) : 2400 - 2402
  • [22] Pentacyclooctaaza as a neutral carrier in coated-wire ion-selective electrode for nickel(II)
    Mazloum-Ardakani, M
    Salavati-Niasari, M
    Amini, MK
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 82 (2-3) : 259 - 264
  • [23] A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone
    Mahajan, RK
    Kaur, I
    Lobana, TS
    TALANTA, 2003, 59 (01) : 101 - 105
  • [24] Manganese(II) Ion-Selective Membrane Electrode Based on N-(2-picolinamido ethyl)-Picolinamide as Neutral Carrier
    Aghaie, M.
    Giahi, M.
    Zawari, M.
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (10) : 2980 - 2984
  • [25] A New PVC-Membrane Based Ion-Selective Electrode for Perchlorate
    Yari, Abdollah
    Shamsipur, Mojtaba
    De Filippo, Greta
    Lippolis, Vito
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2009, 1 (02): : 60 - 70
  • [26] SOME PROPERTIES OF SULFATE ION-SELECTIVE PVC MEMBRANES BASED ON A NEUTRAL CARRIER AND ION-EXCHANGER
    SMIRNOVA, AL
    TARASEVITCH, VN
    RAKHMANKO, EM
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3): : 392 - 395
  • [27] Synthesis and spectroscopic-electrochemical properties of novel ratiometric Hg (II) chemosensor containing Bodipy and the N-phenylaza-15-crown-5 moiety
    Kursunlu, Ahmed Nuri
    Deveci, Pervin
    Guler, Ersin
    JOURNAL OF LUMINESCENCE, 2013, 136 : 430 - 436
  • [28] CATION-RESPONSE MECHANISM OF NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE MEMBRANES
    MORF, WE
    SIMON, W
    HELVETICA CHIMICA ACTA, 1986, 69 (05) : 1120 - 1131
  • [29] A HYDROGEN ION-SELECTIVE LIQUID-MEMBRANE ELECTRODE BASED ON TRI-N-DODECYLAMINE AS NEUTRAL CARRIER
    SCHULTHESS, P
    SHIJO, Y
    PHAM, HV
    PRETSCH, E
    AMMANN, D
    SIMON, W
    ANALYTICA CHIMICA ACTA, 1981, 131 (NOV) : 111 - 116
  • [30] Design and synthesis of sodium ion-selective ionophores based on 16-crown-5 derivatives for an ion-selective electrode
    Suzuki, K
    Sato, K
    Hisamoto, H
    Siswanta, D
    Hayashi, K
    Kasahara, N
    Watanabe, K
    Yamamoto, N
    Sasakura, H
    ANALYTICAL CHEMISTRY, 1996, 68 (01) : 208 - 215