SOME PROPERTIES OF SULFATE ION-SELECTIVE PVC MEMBRANES BASED ON A NEUTRAL CARRIER AND ION-EXCHANGER

被引:13
|
作者
SMIRNOVA, AL [1 ]
TARASEVITCH, VN [1 ]
RAKHMANKO, EM [1 ]
机构
[1] BYELORUSSIAN STATE UNIV, PHYSICOCHEM PROBLEMS RES INST, MINSK 220080, BELARUS
来源
SENSORS AND ACTUATORS B-CHEMICAL | 1994年 / 19卷 / 1-3期
关键词
D O I
10.1016/0925-4005(93)01008-R
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the measurement of SO4 ion activity in aqueous solutions sulfate-selective PVC membranes with different concentrations of ion-exchanger and neutral carrier were prepared and tested. The sulfate ion-selective electrodes (SO4-ISE) were then examined in terms of their response curves and slope in the linear part, selectivity coefficients, and the effect of the pH. Experimental results on selectivity are discussed and compared with those calculated from a mathematical model described earlier.
引用
收藏
页码:392 / 395
页数:4
相关论文
共 50 条
  • [1] SELECTIVE ION-EXCHANGER BEHAVIOR OF NEUTRAL CARRIER ION-SELECTIVE ELECTRODE MEMBRANES
    HORVAI, G
    HORVATH, V
    FARKAS, A
    PUNGOR, E
    TALANTA, 1989, 36 (03) : 403 - 405
  • [2] TRANSPORT PROPERTIES OF NEUTRAL CARRIER ION-SELECTIVE MEMBRANES
    MORF, WE
    WUHRMANN, P
    SIMON, W
    ANALYTICAL CHEMISTRY, 1976, 48 (07) : 1031 - 1039
  • [3] Potentiometric response of ion-selective membranes with ionic liquids as ion-exchanger and plasticizer
    Peng, Bo
    Zhu, Jingwei
    Liu, Xiaojie
    Qin, Yu
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (01) : 308 - 314
  • [4] Effect of lipophilic ion-exchanger leaching on the detection limit of carrier-based ion-selective electrodes
    Telting-Diaz, M
    Bakker, E
    ANALYTICAL CHEMISTRY, 2001, 73 (22) : 5582 - 5589
  • [5] ION-EXCHANGE AT NEUTRAL CARRIER ION-SELECTIVE ELECTRODE MEMBRANES
    HORVATH, V
    HORVAI, G
    PUNGOR, E
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9): : 569 - 571
  • [6] PROPERTIES OF PVC BASED MEMBRANES USED IN ION-SELECTIVE ELECTRODES
    ARMSTRONG, RD
    HORVAI, G
    ELECTROCHIMICA ACTA, 1990, 35 (01) : 1 - 7
  • [7] AN IMPROVED LIQUID ION-EXCHANGER FOR CHLORIDE ION-SELECTIVE MICROELECTRODES
    BAUMGARTEN, CM
    AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (05): : C258 - C263
  • [8] NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODES
    AMMANN, D
    MORF, WE
    ANKER, P
    MEIER, PC
    PRETSCH, E
    SIMON, W
    ION-SELECTIVE ELECTRODE REVIEWS, 1983, 5 (01): : 3 - 92
  • [9] Donnan Failure of Ion-Selective Electrodes with Hydrophilic High-Capacity Ion-Exchanger Membranes
    Ogawara, Shogo
    Carey, Jesse L., III
    Zou, Xu U.
    Bühlmann, Philippe
    ACS SENSORS, 2016, 1 (01): : 95 - 101
  • [10] THIN-FILM ION-SELECTIVE SENSORS BASED ON NEUTRAL CARRIER MEMBRANES
    KEPLINGER, F
    GLATZ, R
    JACHIMOWICZ, A
    URBAN, G
    KOHL, F
    OLCAYTUG, F
    PROHASKA, OJ
    SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 272 - 274