Development of an Evaluation System for Magnetic Resonance Imaging Based Three-Dimensional Modeling of a Transfemoral Prosthetic Socket Using Finite Elements

被引:3
|
作者
Jamaludin, Mohd Syahmi [1 ]
Hanafusa, Akihiko [1 ]
Shinichirou, Yamamoto [1 ]
Agarie, Yukio [2 ]
Otsuka, Hiroshi [3 ]
Ohnishi, Kengo [4 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Tokyo 1358548, Japan
[2] Niigata Univ Hlth & Welf, Dept Supporting Prosthet Orthot, Niigata 9503102, Japan
[3] Univ Human Arts & Sci, Dept Prosthet & Orthot, Saitama 3398539, Japan
[4] Tokyo Denki Univ, Dept Sci & Engn, Tokyo 1208551, Japan
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 18期
关键词
prosthetic socket; finite element method; finite element analysis; transfemoral residuum; biomechanics; bipedal stances; 3D model; RESIDUAL LIMB; TRANSTIBIAL RESIDUUM; CONTACT INTERFACE; VOLUME CHANGE;
D O I
10.3390/app9183662
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Recent technologies have suggested the utilization of three-dimensional (3D) printing technology to enhance the fabrication accuracy of prosthetics. Accordingly, simulations are used to obtain precise parameters for subject-specified prosthetic socket. This study proposes an evaluation system to measure the accuracy of a subject-specific 3D transfemoral residuum model during the interaction with the socket in conjunction with the application of finite element methods. The proposed system can be used in future validations of socket fabrication. The evaluation is based on the measurement of the residuum's soft tissue deformation inside two types of prosthetic sockets. In comparison with other studies, the 3D models were constructed with magnetic resonance images (MRI) with the aid of computer-aided design (CAD) software. The measurement of soft tissue deformation was conducted based on the measurement of the volumetric value of fat, muscle and skin in the pre- and post-donning phases. The result yielded a promising correlation coefficient value between the simulation and the experiment in the soft tissue deformation evaluation. The relation of the muscle-fat ratio in the residuum is extremely important in the determination of the ability of the prosthetic to deform. The environment during the socket fitting session was similar to that defined by the set boundary conditions in simulations. In view of the promising results of this study, the evaluation system proposed herein is considered reliable and is envisaged to be used in future research.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Development of a three-dimensional cell culture system based on microfluidics for nuclear magnetic resonance and optical monitoring
    Esteve, Vicent
    Berganzo, Javier
    Monge, Rosa
    Carmen Martinez-Bisbal, M.
    Villa, Rosa
    Celda, Bernardo
    Fernandez, Luis
    BIOMICROFLUIDICS, 2014, 8 (06):
  • [42] Three-dimensional VCSEL simulation using vector finite elements
    Nyakas, Peter
    NUSOD '07: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON NUMERICAL SIMULATION OF OPTOELECTRONIC DEVICES, 2007, : 45 - +
  • [43] Three-dimensional magnetic recording using ferromagnetic resonance
    Suto, Hirofumi
    Kudo, Kiwamu
    Nagasawa, Tazumi
    Kanao, Taro
    Mizushima, Koichi
    Sato, Rie
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (07)
  • [44] Evaluation of liver function using gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid enhanced magnetic resonance imaging based on a three-dimensional volumetric analysis system
    Kudo, Masashi
    Gotohda, Naoto
    Sugimoto, Motokazu
    Kobayashi, Tatsushi
    Kojima, Motohiro
    Takahashi, Shinichiro
    Konishi, Masaru
    Hayashi, Ryuichi
    HEPATOLOGY INTERNATIONAL, 2018, 12 (04) : 368 - 376
  • [45] Evaluation of liver function using gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid enhanced magnetic resonance imaging based on a three-dimensional volumetric analysis system
    Masashi Kudo
    Naoto Gotohda
    Motokazu Sugimoto
    Tatsushi Kobayashi
    Motohiro Kojima
    Shinichiro Takahashi
    Masaru Konishi
    Ryuichi Hayashi
    Hepatology International, 2018, 12 : 368 - 376
  • [46] Numerical modeling of two parallel tunnels interaction using three-dimensional Finite Elements Method
    Nawel, Bousbia
    Salah, Messast
    GEOMECHANICS AND ENGINEERING, 2015, 9 (06) : 775 - 791
  • [47] Lumbosacral cerebrospinal fluid volume in humans using three-dimensional magnetic resonance imaging
    Sullivan, John T.
    Grouper, Sharon
    Walker, Matthew T.
    Parrish, Todd B.
    McCarthy, Robert J.
    Wong, Cynthia A.
    ANESTHESIA AND ANALGESIA, 2006, 103 (05): : 1306 - 1310
  • [48] Three-dimensional analysis of cardiac magnetic resonance imaging the using spherical harmonics model
    Huang, H
    Pearlman, J
    Shen, L
    Gao, L
    Makedon, FS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 23A - 23A
  • [49] Three-dimensional motion of liver tumors using cine-magnetic resonance imaging
    Kirilova, Anna
    Lockwood, Gina
    Math, M.
    Choi, Perry
    Bana, Neelufer
    Haider, Masoom A.
    Brock, Kristy K.
    Eccles, Cynthia
    Dawson, Laura A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1189 - 1195
  • [50] Three-dimensional concentration field measurements in a mixing layer using magnetic resonance imaging
    Michael J. Benson
    Christopher J. Elkins
    Paul D. Mobley
    Marcus T. Alley
    John K. Eaton
    Experiments in Fluids, 2010, 49 : 43 - 55