Development of an Evaluation System for Magnetic Resonance Imaging Based Three-Dimensional Modeling of a Transfemoral Prosthetic Socket Using Finite Elements

被引:3
|
作者
Jamaludin, Mohd Syahmi [1 ]
Hanafusa, Akihiko [1 ]
Shinichirou, Yamamoto [1 ]
Agarie, Yukio [2 ]
Otsuka, Hiroshi [3 ]
Ohnishi, Kengo [4 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Tokyo 1358548, Japan
[2] Niigata Univ Hlth & Welf, Dept Supporting Prosthet Orthot, Niigata 9503102, Japan
[3] Univ Human Arts & Sci, Dept Prosthet & Orthot, Saitama 3398539, Japan
[4] Tokyo Denki Univ, Dept Sci & Engn, Tokyo 1208551, Japan
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 18期
关键词
prosthetic socket; finite element method; finite element analysis; transfemoral residuum; biomechanics; bipedal stances; 3D model; RESIDUAL LIMB; TRANSTIBIAL RESIDUUM; CONTACT INTERFACE; VOLUME CHANGE;
D O I
10.3390/app9183662
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Recent technologies have suggested the utilization of three-dimensional (3D) printing technology to enhance the fabrication accuracy of prosthetics. Accordingly, simulations are used to obtain precise parameters for subject-specified prosthetic socket. This study proposes an evaluation system to measure the accuracy of a subject-specific 3D transfemoral residuum model during the interaction with the socket in conjunction with the application of finite element methods. The proposed system can be used in future validations of socket fabrication. The evaluation is based on the measurement of the residuum's soft tissue deformation inside two types of prosthetic sockets. In comparison with other studies, the 3D models were constructed with magnetic resonance images (MRI) with the aid of computer-aided design (CAD) software. The measurement of soft tissue deformation was conducted based on the measurement of the volumetric value of fat, muscle and skin in the pre- and post-donning phases. The result yielded a promising correlation coefficient value between the simulation and the experiment in the soft tissue deformation evaluation. The relation of the muscle-fat ratio in the residuum is extremely important in the determination of the ability of the prosthetic to deform. The environment during the socket fitting session was similar to that defined by the set boundary conditions in simulations. In view of the promising results of this study, the evaluation system proposed herein is considered reliable and is envisaged to be used in future research.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] A three-dimensional finite element model of the transibial residual limb and prosthetic socket to predict skin temperatures
    Peery, Jeffrey T.
    Klute, Glenn K.
    Blevins, Joanna J.
    Ledoux, William R.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2006, 14 (03) : 336 - 343
  • [22] Three-dimensional magnetic resonance based volumetry in multiple system atrophy
    Schocke, M
    Seppi, K
    Kremser, C
    Jaschke, W
    Poewe, W
    Wenning, G
    MOVEMENT DISORDERS, 2002, 17 : S262 - S262
  • [23] An improved three-dimensional concentration measurement technique using magnetic resonance imaging
    Banko, Andrew J.
    Benson, Michael J.
    Gunady, Ian E.
    Elkins, Christopher J.
    Eaton, John K.
    EXPERIMENTS IN FLUIDS, 2020, 61 (02)
  • [24] Three-dimensional reconstruction of fetal abnormalities using ultrasonography and magnetic resonance imaging
    Werner, Heron
    Marcondes, Maene
    Daltro, Pedro
    Fazecas, Tatiana
    Ribeiro, Bianca Guedes
    Nogueira, Renata
    Araujo Junior, Edward
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2019, 32 (20): : 3502 - 3508
  • [25] An improved three-dimensional concentration measurement technique using magnetic resonance imaging
    Andrew J. Banko
    Michael J. Benson
    Ian E. Gunady
    Christopher J. Elkins
    John K. Eaton
    Experiments in Fluids, 2020, 61
  • [26] Three-dimensional computation of a magnetic field by mixed finite elements and boundary elements
    Laminie, J
    Mefire, SM
    APPLIED NUMERICAL MATHEMATICS, 2000, 35 (03) : 221 - 244
  • [27] Quantitation of articular cartilage using magnetic resonance imaging and three-dimensional reconstruction
    Marshall, KW
    Mikulis, DJ
    Guthrie, BM
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (06) : 814 - 823
  • [28] Morphological analysis and quantitative evaluation of myopic maculopathy by three-dimensional magnetic resonance imaging
    Yu, X.
    Ma, W.
    Liu, B.
    Li, Z.
    Zhao, X.
    Tanumiharjo, S.
    Chen, X.
    Lyu, C.
    Ao, H.
    Li, S.
    Li, Y.
    Lu, L.
    EYE, 2018, 32 (04) : 782 - 787
  • [29] Morphological analysis and quantitative evaluation of myopic maculopathy by three-dimensional magnetic resonance imaging
    X Yu
    W Ma
    B Liu
    Z Li
    X Zhao
    S Tanumiharjo
    X Chen
    C Lyu
    H Ao
    S Li
    Y Li
    L Lu
    Eye, 2018, 32 : 782 - 787
  • [30] A Three-Dimensional Finite Element Model Constructed Using Magnetic Resonance Images of a Knee
    Zhan, Sheng-Liang
    Xia, Jing
    Guo, Tong-Tong
    PROCEEDINGS OF THE 3RD ANNUAL INTERNATIONAL CONFERENCE ON MECHANICS AND MECHANICAL ENGINEERING (MME 2016), 2017, 105 : 1015 - 1021