Development of an Evaluation System for Magnetic Resonance Imaging Based Three-Dimensional Modeling of a Transfemoral Prosthetic Socket Using Finite Elements

被引:3
|
作者
Jamaludin, Mohd Syahmi [1 ]
Hanafusa, Akihiko [1 ]
Shinichirou, Yamamoto [1 ]
Agarie, Yukio [2 ]
Otsuka, Hiroshi [3 ]
Ohnishi, Kengo [4 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Tokyo 1358548, Japan
[2] Niigata Univ Hlth & Welf, Dept Supporting Prosthet Orthot, Niigata 9503102, Japan
[3] Univ Human Arts & Sci, Dept Prosthet & Orthot, Saitama 3398539, Japan
[4] Tokyo Denki Univ, Dept Sci & Engn, Tokyo 1208551, Japan
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 18期
关键词
prosthetic socket; finite element method; finite element analysis; transfemoral residuum; biomechanics; bipedal stances; 3D model; RESIDUAL LIMB; TRANSTIBIAL RESIDUUM; CONTACT INTERFACE; VOLUME CHANGE;
D O I
10.3390/app9183662
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Recent technologies have suggested the utilization of three-dimensional (3D) printing technology to enhance the fabrication accuracy of prosthetics. Accordingly, simulations are used to obtain precise parameters for subject-specified prosthetic socket. This study proposes an evaluation system to measure the accuracy of a subject-specific 3D transfemoral residuum model during the interaction with the socket in conjunction with the application of finite element methods. The proposed system can be used in future validations of socket fabrication. The evaluation is based on the measurement of the residuum's soft tissue deformation inside two types of prosthetic sockets. In comparison with other studies, the 3D models were constructed with magnetic resonance images (MRI) with the aid of computer-aided design (CAD) software. The measurement of soft tissue deformation was conducted based on the measurement of the volumetric value of fat, muscle and skin in the pre- and post-donning phases. The result yielded a promising correlation coefficient value between the simulation and the experiment in the soft tissue deformation evaluation. The relation of the muscle-fat ratio in the residuum is extremely important in the determination of the ability of the prosthetic to deform. The environment during the socket fitting session was similar to that defined by the set boundary conditions in simulations. In view of the promising results of this study, the evaluation system proposed herein is considered reliable and is envisaged to be used in future research.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Three-dimensional modeling of the human eye based on magnetic resonance imaging
    Singh, Krish D.
    Logan, Nicola S.
    Gilmartin, Bernard
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (06) : 2272 - 2279
  • [2] Three-Dimensional Magnetic Resonance Imaging in the Musculoskeletal System
    Ahlawat, Shivani
    Kumar, Neil M.
    Ghasemi, Ali
    Fayad, Laura M.
    INVESTIGATIVE RADIOLOGY, 2025, 60 (03) : 184 - 197
  • [3] Evaluation of lung volumetry using dynamic three-dimensional magnetic resonance imaging
    Plathow, C
    Schoebinger, M
    Fink, C
    Ley, S
    Puderbach, M
    Eichinger, M
    Bock, M
    Meinzer, HP
    Kauczor, HU
    INVESTIGATIVE RADIOLOGY, 2005, 40 (03) : 173 - 179
  • [4] Three-dimensional finite element analyses on the transtibial residual limb and its prosthetic socket
    Hong Kong Polytechnic Univ, Hong Kong, Hong Kong
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2000, 17 (04): : 403 - 406
  • [5] Three-dimensional magnetic resonance imaging for groundwater
    Legchenko, A.
    Descloitres, M.
    Vincent, C.
    Guyard, H.
    Garambois, S.
    Chalikakis, K.
    Ezersky, M.
    NEW JOURNAL OF PHYSICS, 2011, 13
  • [6] Three-dimensional localization of impacted teeth using magnetic resonance imaging
    O. Tymofiyeva
    K. Rottner
    P. M. Jakob
    E.-J. Richter
    P. Proff
    Clinical Oral Investigations, 2010, 14 : 169 - 176
  • [7] Three-Dimensional Visualization Using Magnetic Resonance Imaging for Episcleral Brachytherapy
    Rodriguez, V.
    Bertelsman, C.
    DeWees, T.
    Hu, Y.
    Rao, P. Kumar
    Garcia-Ramirez, J.
    Grigsby, P.
    Esthappan, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [8] Three-dimensional localization of impacted teeth using magnetic resonance imaging
    Tymofiyeva, O.
    Rottner, K.
    Jakob, P. M.
    Richter, E. -J.
    Proff, P.
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (02) : 169 - 176
  • [9] Modeling of permanent magnets in three-dimensional space using edge finite elements
    Cingoski, V
    Yamashita, H
    JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) : 4088 - 4090