Measurement of glycosylated ferritin with Concanavalin A: Assay design, optimization and validation

被引:4
|
作者
Raynor, Alexandre [1 ]
Peoc'h, Katell [1 ,2 ,3 ]
Boutten, Anne [1 ]
机构
[1] Hop Univ Paris Nord Val Seine, AP HP, Dept Biochim, Site Bichat, Paris, France
[2] Univ Paris, Ctr Rech Sur Inflarnmat, INSERM UMRs 1149, CNRS,ERL8252,UFR Med Bichat, F-75018 Paris, France
[3] APHP Nord, AP HP, Lab Excellence GR Ex, Paris, France
关键词
Glycosylated ferritin; Still's disease; Macrophage activation syndrome; Gaucher disease; Concanavalin A; SERUM FERRITIN; CLASSIFICATION CRITERIA; DIAGNOSIS;
D O I
10.1016/j.jchromb.2022.123184
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Introduction: Ferritin is the major iron-storage glycoprotein found in all tissues. Ferritin glycosylation can be assessed by the differential affinities of ferritin glycoforms for Concanavalin A (ConA), a lectin. The fraction of serum ferritin bound to ConA is called "glycosylated ferritin" (GF). Low GF reflects macrophagic activation and is an essential biomarker used in adult-onset Still's disease (AOSD), macrophage activation syndrome (MAS) and Gaucher disease diagnosis and therapeutic management. To date, no complete assay description and method validation according to the ISO 15189 standard has been published. This study aimed to describe and validate our method used for GF measurement and describe GF values observed in patients.Materials and methods: Ferritin glycoforms were separated based on their affinities for ConA using commercially available TRIS-barbital buffer, Sepharose and ConA/Sepharose 4B gels. Ferritin concentrations were measured on the Siemens Dimension Vista 1500 (R). We analysed 16,843 GF values obtained between 2000 and 2021 from our database of patients.Results: Optimal separation of ferritin glycoforms was obtained by 15-min incubation of serum with ConA/ Sepharose at pH 8. The optimized volume were 0.4 mL for total serum ferritin (TSF) 30-1000 mu g/L and 0.5 mL for TSF 1000-2500 mu g/L. Serum with higher TSF should be pre-diluted in the TRIS-barbital buffer. Reproducibility of ferritin measurement in the TRIS-barbital buffer matrix was excellent (intra-assay CV < 1%; inter-assay CV < 4%). Reproducibility of GF assay was good (intra-assay CV < 10% for low and high ferritin samples, respectively; and inter-assay CV < 10%). Inter-operator variability was 21.6% for GF < 20%. Ferritin was stable for up to 3 days in the TRIS-barbital buffer. An inter-laboratory exchange program conducted with another French hospital showed good agreement between results. In our database, <20% GF levels were scarce, compatible with the low prevalence of Still's disease, MAS, and Gaucher disease. The 95% confidence interval for GF was [26-58]%, lower than values described in the literature for healthy individuals.Conclusion: Thanks to good performances, this technique can become readily available for laboratories servicing patients with AOSD, MAS (including severe COVID-19 patients) and Gaucher disease patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Validation of an enzyme-linked immunosorbent assay for measurement of feline haptoglobin
    Stiller, Jenny
    Jasensky, Anne-Katherine
    Hennies, Mark
    Einspanier, Ralf
    Kohn, Barbara
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2016, 28 (03) : 235 - 243
  • [42] Validation of a novel homogeneous assay for of HDL3-C measurement
    Ashmaig, M. E.
    Gupta, S.
    McConnell, J. P.
    Warnick, G. R.
    CLINICA CHIMICA ACTA, 2013, 425 : 37 - 41
  • [43] DEVELOPMENT AND VALIDATION OF A KINETIC FLUORIMETRIC ASSAY FOR THE MEASUREMENT OF ANGIOTENSIN CONVERTING ENZYME
    MAGUIRE, GA
    PRICE, CP
    CLINICAL BIOCHEMISTRY, 1983, 16 (05) : A15 - A15
  • [44] Validation of the dimensionality emergence assay for the measurement of innate anxiety in laboratory mice
    Jain, Apar
    Dvorkin, Anna
    Fonio, Ehud
    Golani, Ilan
    Gross, Cornelius T.
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2012, 22 (02) : 153 - 163
  • [45] Validation of an automated immunoturbidimetric assay for measurement of plasma D-dimer
    Bozic, M
    Stegnar, M
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (07) : 958 - 962
  • [46] Validation of hyaluronic acid measurement using a radiometric assay in human serum
    Deschamps, Y
    Ayotte, N
    CLINICAL CHEMISTRY, 1996, 42 (06) : 341 - 341
  • [47] Validation of erythromycin microbiological assay using an alternative experimental design
    Lourenco, Felipe Rebello
    Kaneko, Telma Mary
    Andreoli Pinto, Terezinha De Jesus
    JOURNAL OF AOAC INTERNATIONAL, 2007, 90 (04) : 1107 - 1110
  • [48] Validation of erythromycin microbiological assay using an alternative experimental design
    Lourenço, Felipe Rebello
    Kaneko, Telma Mary
    De Jesus Andreoli Pinto, Terezinha
    Journal of AOAC International, 1600, 90 (04): : 1107 - 1110
  • [49] Design and Optimization of a Monkeypox virus Specific Serological Assay
    Taha, Taha Y.
    Townsend, Michael B.
    Pohl, Jan
    Karem, Kevin L.
    Damon, Inger K.
    Mbala Kingebeni, Placide
    Muyembe Tamfum, Jean-Jacques
    Martin, James W.
    Pittman, Phillip R.
    Huggins, John W.
    Satheshkumar, Panayampalli S.
    Bagarozzi Jr, Dennis A.
    Reynolds, Mary G.
    Hughes, Laura J.
    PATHOGENS, 2023, 12 (03):
  • [50] Overcoming Obstacles in the Implementation of Factorial Design for Assay Optimization
    Shaw, Robert
    Fitzek, Martina
    Mouchet, Elizabeth
    Walker, Graeme
    Jarvis, Philip
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2015, 13 (02) : 88 - 93