Measurement of glycosylated ferritin with Concanavalin A: Assay design, optimization and validation

被引:4
|
作者
Raynor, Alexandre [1 ]
Peoc'h, Katell [1 ,2 ,3 ]
Boutten, Anne [1 ]
机构
[1] Hop Univ Paris Nord Val Seine, AP HP, Dept Biochim, Site Bichat, Paris, France
[2] Univ Paris, Ctr Rech Sur Inflarnmat, INSERM UMRs 1149, CNRS,ERL8252,UFR Med Bichat, F-75018 Paris, France
[3] APHP Nord, AP HP, Lab Excellence GR Ex, Paris, France
关键词
Glycosylated ferritin; Still's disease; Macrophage activation syndrome; Gaucher disease; Concanavalin A; SERUM FERRITIN; CLASSIFICATION CRITERIA; DIAGNOSIS;
D O I
10.1016/j.jchromb.2022.123184
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Introduction: Ferritin is the major iron-storage glycoprotein found in all tissues. Ferritin glycosylation can be assessed by the differential affinities of ferritin glycoforms for Concanavalin A (ConA), a lectin. The fraction of serum ferritin bound to ConA is called "glycosylated ferritin" (GF). Low GF reflects macrophagic activation and is an essential biomarker used in adult-onset Still's disease (AOSD), macrophage activation syndrome (MAS) and Gaucher disease diagnosis and therapeutic management. To date, no complete assay description and method validation according to the ISO 15189 standard has been published. This study aimed to describe and validate our method used for GF measurement and describe GF values observed in patients.Materials and methods: Ferritin glycoforms were separated based on their affinities for ConA using commercially available TRIS-barbital buffer, Sepharose and ConA/Sepharose 4B gels. Ferritin concentrations were measured on the Siemens Dimension Vista 1500 (R). We analysed 16,843 GF values obtained between 2000 and 2021 from our database of patients.Results: Optimal separation of ferritin glycoforms was obtained by 15-min incubation of serum with ConA/ Sepharose at pH 8. The optimized volume were 0.4 mL for total serum ferritin (TSF) 30-1000 mu g/L and 0.5 mL for TSF 1000-2500 mu g/L. Serum with higher TSF should be pre-diluted in the TRIS-barbital buffer. Reproducibility of ferritin measurement in the TRIS-barbital buffer matrix was excellent (intra-assay CV < 1%; inter-assay CV < 4%). Reproducibility of GF assay was good (intra-assay CV < 10% for low and high ferritin samples, respectively; and inter-assay CV < 10%). Inter-operator variability was 21.6% for GF < 20%. Ferritin was stable for up to 3 days in the TRIS-barbital buffer. An inter-laboratory exchange program conducted with another French hospital showed good agreement between results. In our database, <20% GF levels were scarce, compatible with the low prevalence of Still's disease, MAS, and Gaucher disease. The 95% confidence interval for GF was [26-58]%, lower than values described in the literature for healthy individuals.Conclusion: Thanks to good performances, this technique can become readily available for laboratories servicing patients with AOSD, MAS (including severe COVID-19 patients) and Gaucher disease patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Validation of an automated assay for measurement of bovine plasma ceruloplasmin
    Hussein, Hussein Awad
    Baeumer, Jacqueline
    Staufenbiel, Rudolf
    ACTA VETERINARIA SCANDINAVICA, 2019, 61 (1)
  • [22] Optimization and validation of a colorimetric assay for Tetrahymena sp survival
    Zilberg, Dina
    Sinai, Tamar
    RESEARCH IN MICROBIOLOGY, 2006, 157 (04) : 355 - 359
  • [23] Design and Validation of a SNaPshot Assay for Melanoma and Glioblastoma Patients
    de Abreu, F.
    Schwab, M. C.
    Smith, T. M.
    Rhodes, C. H.
    Hickey, W. F.
    Fadul, C. E.
    Storm, C. A.
    Seidel, G. D.
    Yan, S.
    Brennick, J. B.
    Ernstoff, M. S.
    Tsongalis, G. J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 942 - 942
  • [24] Use of glycosylated ferritin assay to aid the diagnosis of adult-onset Still’s disease: a local laboratory experience in Hong Kong
    Jeffrey Sung-Shing Kwok
    Priscilla Ching-Han Wong
    Ming Chi Luk
    Michael Ho-Ming Chan
    Rheumatology International, 2012, 32 : 2583 - 2584
  • [25] Using the Design of Experiments for Development, Validation, and Optimization of HPLC-UV Assay of Tamoxifen Citrate in Polymeric Nanoparticles
    Muzna Ali Khattak
    Zafar Iqbal
    Nasir Fazli
    Fahim Ullah Khan
    SumairaIrum Khan
    Shazma Gohar
    Mirina Sakhi
    Muhammad Iqbal
    Sadia Pervez
    Pharmaceutical Chemistry Journal, 2022, 56 : 1297 - 1306
  • [26] Use of glycosylated ferritin assay to aid the diagnosis of adult-onset Still's disease: a local laboratory experience in Hong Kong
    Kwok, JeVrey Sung-Shing
    Wong, Priscilla Ching-Han
    Luk, Ming Chi
    Chan, Michael Ho-Ming
    RHEUMATOLOGY INTERNATIONAL, 2012, 32 (08) : 2583 - 2584
  • [27] USING THE DESIGN OF EXPERIMENTS FOR DEVELOPMENT, VALIDATION, AND OPTIMIZATION OF HPLC-UV ASSAY OF TAMOXIFEN CITRATE IN POLYMERIC NANOPARTICLES
    Khattak, Muzna Ali
    Iqbal, Zafar
    Fazli, Nasir
    Khan, Fahim Ullah
    Khan, SumairaIrum
    Gohar, Shazma
    Sakhi, Mirina
    Iqbal, Muhammad
    Pervez, Sadia
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2022, 56 (09) : 1297 - 1306
  • [28] Design, optimization, and validation of multiplex immunofluorescence assay for detecting biomarker expression on circulating tumor cells in breast cancer
    Kumar, Tanya
    Thangavel, Hariprasad
    Bhat, Raksha
    Abdulkareem, Noor M.
    Dobrolecki, Lacey E.
    Lewis, Michael T.
    Trivedi, Meghana, V
    CANCER RESEARCH, 2020, 80 (16)
  • [29] Assay optimization: A statistical design of experiments approach
    Altekar, Maneesha
    Homon, Carol A.
    Kashem, Mohammed A.
    Mason, Steven W.
    Nelson, Richard M.
    Patnaude, Lori A.
    Yingling, Jeffrey
    Taylor, Paul B.
    JALA - Journal of the Association for Laboratory Automation, 2006, 11 (01): : 33 - 41
  • [30] Assay optimization: A statistical design of experiments approach
    Altekar, Maneesha
    Homon, Carol A.
    Kashem, Mohammed A.
    Mason, Steven W.
    Nelson, Richard M.
    Patnaude, Lori A.
    Yingling, Jeffrey
    Taylor, Paul B.
    CLINICS IN LABORATORY MEDICINE, 2007, 27 (01) : 139 - +