Autoignited combustion testing in a water-cooled scramjet combustor

被引:3
|
作者
Kanda, T [1 ]
Chinzei, N [1 ]
Kudo, K [1 ]
Murakami, A [1 ]
Hiraiwa, T [1 ]
机构
[1] Space Propuls Res Ctr, Combined Propuls Res Unit, Engine Syst Team, Kimigaya, Kakuda, Japan
关键词
D O I
10.2514/1.11381
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
A water-cooled scramjet combustor was tested to study the effects of pressure, combustor length, fuel-injection style, and wall temperature on autoignited combustion performance. The tests were conducted with an inflow Mach number of 2.5; total pressure of air of 1, 1.5, and 2 MPa; and total temperature of air from 1200 to 2600 K. High-enthalpy air was produced using a vitiation heater. The combustion condition was detected by an increase of temperature in the combustor, which was related to a local combustion condition. When hydrogen fuel was supplied transversely to the combustor wall downstream of the backward-facing step, the autoignited combustion performance degraded with an increase of the airflow pressure under a condition of low total temperature of the vitiated air. The ignition region was around the second explosion limit. The presence of H2O in the air further retarded ignition under the high-pressure condition. In high-temperature conditions, the combustion performance was improved by the increase of pressure. With the long combustor with a downstream extension, the autoignited combustion limit on the air temperature became lower. A long separation region was presumed to exist downstream of the transverse fuel jet. Under such conditions, the residence time of the mixture increased, and the ability of autoignited combustion could be improved. This effect of the extension of the combustor length decreased with the increase of pressure. Parallel fuel injection from the step base showed low autoignited combustion ability. In the parallel injection, autoignition would initiate at the base of the step, where the pressure was low and the size of the base was small. In the water-cooled combustor, the autoignited combustion limit on the air temperature was higher than that in the uncooled combustor. This fact suggested that the ignition source existed near the wall, for example, in the separation region.
引用
收藏
页码:657 / 664
页数:8
相关论文
共 50 条
  • [31] Supercritical Water-Cooled Reactors
    Cai, Jiejin
    Renault, Claude
    Gou, Junli
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2014, 2014
  • [32] Water-cooled argon laser
    不详
    OPTICS AND LASER TECHNOLOGY, 1996, 28 (03): : R6 - R6
  • [33] Water-cooled panel care
    Schleiden, RF
    Lee, M
    58TH ELECTRIC FURNACE CONFERENCE AND 17TH PROCESS TECHNOLOGY CONFERENCE PROCEEDINGS, 2000, 17 : 259 - 261
  • [34] MATERIALS FOR WATER-COOLED REACTORS
    FRANCIS, WC
    ANNUAL REVIEW OF NUCLEAR SCIENCE, 1968, 18 : 465 - &
  • [35] USE OF WATER-COOLED WALLS
    SOUCHAL, G
    REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 1980, 77 (10): : E119 - E119
  • [36] GLUED WATER-COOLED WINDINGS
    KATRUKHIN, YK
    KOCHAROV, NG
    KHRUSTALEV, BP
    BAZAN, CE
    TROJNAR, KA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (05) : 1363 - 1365
  • [37] Water-cooled bimorph correctors
    Samarkin, Vadirn
    Aleksandrov, Alexander
    Dubikovsky, Valeri
    Kudryashov, Alexis
    5TH INTERNATIONAL WORKSHOP ON ADAPTIVE OPTICS FOR INDUSTRY AND MEDICINE, 2005, 6018
  • [38] WATER-COOLED STATIC CONVERTERS
    VOGEL, X
    SVARC, M
    BROWN BOVERI REVIEW, 1974, 61 (9-10): : 421 - 423
  • [39] An iterative analysis and design method for study of coupling processes of combustion and heat transfer in actively-cooled scramjet combustor
    Wang, Xin-Zhu
    Zhang, Tai-Chang
    Lu, Yang
    Fan, Xue-Jun
    Tuijin Jishu/Journal of Propulsion Technology, 2014, 35 (02): : 213 - 219
  • [40] WATER-COOLED GAS-TURBINE MONOMETALLIC NOZZLE FABRICATION AND TESTING
    SCHILKE, PW
    DEGEORGE, CL
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1982, 104 (03): : 607 - 616