Autoignited combustion testing in a water-cooled scramjet combustor

被引:3
|
作者
Kanda, T [1 ]
Chinzei, N [1 ]
Kudo, K [1 ]
Murakami, A [1 ]
Hiraiwa, T [1 ]
机构
[1] Space Propuls Res Ctr, Combined Propuls Res Unit, Engine Syst Team, Kimigaya, Kakuda, Japan
关键词
D O I
10.2514/1.11381
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
A water-cooled scramjet combustor was tested to study the effects of pressure, combustor length, fuel-injection style, and wall temperature on autoignited combustion performance. The tests were conducted with an inflow Mach number of 2.5; total pressure of air of 1, 1.5, and 2 MPa; and total temperature of air from 1200 to 2600 K. High-enthalpy air was produced using a vitiation heater. The combustion condition was detected by an increase of temperature in the combustor, which was related to a local combustion condition. When hydrogen fuel was supplied transversely to the combustor wall downstream of the backward-facing step, the autoignited combustion performance degraded with an increase of the airflow pressure under a condition of low total temperature of the vitiated air. The ignition region was around the second explosion limit. The presence of H2O in the air further retarded ignition under the high-pressure condition. In high-temperature conditions, the combustion performance was improved by the increase of pressure. With the long combustor with a downstream extension, the autoignited combustion limit on the air temperature became lower. A long separation region was presumed to exist downstream of the transverse fuel jet. Under such conditions, the residence time of the mixture increased, and the ability of autoignited combustion could be improved. This effect of the extension of the combustor length decreased with the increase of pressure. Parallel fuel injection from the step base showed low autoignited combustion ability. In the parallel injection, autoignition would initiate at the base of the step, where the pressure was low and the size of the base was small. In the water-cooled combustor, the autoignited combustion limit on the air temperature was higher than that in the uncooled combustor. This fact suggested that the ignition source existed near the wall, for example, in the separation region.
引用
收藏
页码:657 / 664
页数:8
相关论文
共 50 条
  • [21] Testing candidate interlayers for an enhanced water-cooled divertor target
    Hancock, David
    Barrett, Tom
    Foster, James
    Fursdon, Mike
    Keech, Gregory
    McIntosh, Simon
    Timmis, William
    Rieth, Michael
    Reiser, Jens
    FUSION ENGINEERING AND DESIGN, 2015, 98-99 : 1323 - 1327
  • [22] Design research of an actively fuel-cooled scramjet combustor
    Yang, Yang
    Zhang, Lei
    Zhang, Ruo-Ling
    Jiang, Jin
    Zhao, Guo-Zhu
    Tuijin Jishu/Journal of Propulsion Technology, 2014, 35 (02): : 208 - 212
  • [23] Experiment on variation of combustion reaction region in a scramjet combustor
    He Z.
    Le J.
    Tian Y.
    Zhong F.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2023, 38 (10): : 2370 - 2382
  • [24] Effect of Combustor Configuration on Flow and Combustion in a Scramjet Engine
    Yang, Inyoung
    Lee, Yang Ji
    Lee, Kyung Jae
    Park, Chul
    JOURNAL OF PROPULSION AND POWER, 2013, 29 (03) : 751 - 756
  • [25] Thermochemical exploration of hydrogen combustion in generic scramjet combustor
    Dharavath, Malsur
    Manna, P.
    Chakraborty, Debasis
    AEROSPACE SCIENCE AND TECHNOLOGY, 2013, 24 (01) : 264 - 274
  • [26] On the Numerical Simulation of Combustion in a Scramjet Combustor Using OpenFOAM
    Zhukov V.T.
    Novikova N.D.
    Feodoritova O.B.
    Mathematical Models and Computer Simulations, 2019, 11 (2) : 266 - 276
  • [27] TRENDS OF USING AND TESTING MATERIALS IN WATER-COOLED NUCLEAR-REACTORS
    BERGEMANN, W
    NEUE HUTTE, 1978, 23 (12): : 437 - 439
  • [28] WATER-COOLED GAS TURBINE MONOMETALLIC NOZZLE FABRICATION AND TESTING.
    SCHILKE, P.W.
    DEGEORGE, C.L.
    1982, V 104 (N 3): : 607 - 616
  • [29] AIR-COOLED OR WATER-COOLED ENGINES
    不详
    LANDBOUWMECHANISATIE, 1968, 19 (11): : 1116 - &
  • [30] Design and testing of an oil-free centrifugal water-cooled chiller
    Sishtla, VM
    INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS, 1999, 1999 (06): : 505 - 521