The effect of ionising radiation on poly(methyl methacrylate) used in intraocular lenses

被引:8
|
作者
Pratt, C. M. [1 ]
Barton, S. [1 ]
McGonigle, E. [1 ]
Kishi, M. [1 ]
Foot, P. J. S. [1 ]
机构
[1] Kingston Univ, Sch Chem & Pharmaceut Sci, Mat Res Grp, Kingston upon Thames KT1 2EE, Surrey, England
关键词
PMMA; intraocular; sterilisation; irradiation; SEC; FT-IR;
D O I
10.1016/j.polymdegradstab.2006.04.006
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Gamma radiation is increasingly being used to sterilise intraocular lenses (IOLs) made from poly(methyl methacrylate) (PNIMA). In this study, samples of PMMA used in the fabrication of IOLs were exposed to irradiation doses typically used for their sterilisation. The effect of this treatment on the polymer was analysed by size-exclusion chromatography (SEC), UV-visible and infrared spectroscopy and scanning electron microscopy (SEM). The PMMA was found to have undergone chain scission, decarboxylation and colour change following the irradiation. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2315 / 2317
页数:3
相关论文
共 50 条
  • [21] The effect of additives on the enhancement of methyl methacrylate grafting to cellulose in the presence of UV and ionising radiation
    Viengkhou, V
    Ng, LT
    Garnett, JL
    RADIATION PHYSICS AND CHEMISTRY, 1997, 49 (05): : 595 - 602
  • [22] INFLAMMATORY RESPONSE IN THE RABBIT EYE AFTER INTRAOCULAR IMPLANTATION WITH POLY(METHYL METHACRYLATE) AND HEPARIN SURFACE MODIFIED INTRAOCULAR LENSES
    LUNDGREN, B
    OCKLIND, A
    HOLST, A
    HARFSTRAND, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (01): : 65 - 70
  • [23] THE BINKHORST MEDAL LECTURE - BIOLOGIC RELATIONSHIP BETWEEN POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES AND UVEAL TISSUE
    OBSTBAUM, SA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (03): : 219 - 231
  • [24] Capsule contraction after continuous curvilinear capsulorhexis: Poly(methyl methacrylate) versus silicone intraocular lenses
    Cochener, B
    Jacq, PL
    Colin, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (10): : 1362 - 1369
  • [25] Straight-entrance, sclerocorneal valve incision with horizontal sutures for poly(methyl methacrylate) intraocular lenses
    Menapace, R
    Vass, C
    Radax, U
    Strenn, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (07): : 882 - 890
  • [26] Posterior capsule opacification after phacoemulsification:: Foldable acrylic versus poly(methyl methacrylate) intraocular lenses
    Oner, FH
    Gunenc, Ü
    Ferliel, ST
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (05): : 722 - 726
  • [27] Simulation and fabrication of poly methyl methacrylate infrared lenses
    Tsui, Chun-Chao
    Su, Guo-Dung J.
    INFRARED SENSORS, DEVICES, AND APPLICATIONS AND SINGLE PHOTON IMAGING II, 2011, 8155
  • [28] TEMPERATURE EFFECT ON THE RADIATION-DEGRADATION OF POLY(METHYL METHACRYLATE)
    YOSHIDA, H
    ICHIKAWA, T
    RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6) : 921 - 924
  • [29] Temperature effect on the radiation-degradation of poly(methyl methacrylate)
    Yoshida, Hiroshi
    Ichikawa, Tsuneki
    Radiation Physics and Chemistry, 1995, 46 (4-6 pt 1):
  • [30] The effect of ionizing radiation on intraocular lenses
    Ellerin, BE
    Nisce, LZ
    Roberts, CW
    Thornell, C
    Sabbas, A
    Wang, HL
    Li, PM
    Nori, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01): : 184 - 208