Determination of hydrogen sulfide in gasoline by Au nanoclusters modified glassy carbon electrode

被引:33
|
作者
Yang, Bo [1 ]
Wang, Shuqing [1 ]
Tian, Songbai [1 ]
Liu, Lingzhi [2 ]
机构
[1] Res Inst Petr Proc, Beijing 100083, Peoples R China
[2] Qinzhou Entry Exit Inspect & Quarantine Bur, Qinzhou 535000, Guangxi, Peoples R China
关键词
Hydrogen sulfide; Gasoline; Au; Nanocluster; Modified electrode; ELECTROCHEMICAL DETERMINATION; GAS SENSORS; SULFUR; ADSORPTION; NANOTUBES; OXIDATION; SYSTEM; SNO2;
D O I
10.1016/j.elecom.2009.04.007
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A promising hydrogen sulfide (H2S) sensor was prepared by electrodeposition of Au nanoclusters on glassy carbon electrode (GCE) and the surface structure was characterized by SEM and EDAX. These flower-like form Au nanoclusters, which were made up of highly dense clustering Au nanorods with an average diameter of 20 nm and length up to 80 nm, had an average size about 600 nm and uniformly distributed on the GCE surface. The electrocatalytic oxidation of H2S in gasoline was performed on this modified electrode, which had a satisfactory liner response to H2S in the range of 1-80 ppm and a detection limit of 0.45 ppm (s/n = 3). This sensor was sensitive, selective and stable. (C) 2009 Published by Elsevier B.V.
引用
收藏
页码:1230 / 1233
页数:4
相关论文
共 50 条
  • [41] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    I. Baranowska
    K. Bijak
    Journal of Analytical Chemistry, 2013, 68 : 891 - 895
  • [43] Ag/Au Modified Nafion Coated Glassy Carbon Electrode for the Detection of Metronidazole
    Khanfar, Mohammad F.
    Al Absi, Naela
    Abu-Nameh, Eyad S. M.
    Saket, Munib M.
    Khorma, Natalie
    Al Daoud, Raya
    Alnuman, Nasim
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (04): : 3265 - 3280
  • [44] Hydrogen evolution reaction on glassy carbon electrode modified with titanyl phthalocyanines
    Koca, Atif
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (05) : 2107 - 2112
  • [45] Glassy carbon electrode modified with Nafion-Au colloids for clenbuterol electroanalysis
    Liu, Lijing
    Pan, Haibo
    Du, Min
    Xie, Wenqin
    Wang, Jian
    ELECTROCHIMICA ACTA, 2010, 55 (24) : 7240 - 7245
  • [46] Electrochemical determination of bisphenol A with a glassy carbon electrode modified with gold nanodendrites
    Chen, Wan-Yi
    Mei, Li-Ping
    Feng, Jiu-Ju
    Yuan, Tao
    Wang, Ai-Jun
    Yu, Haiying
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 703 - 709
  • [47] Nafion-modified glassy carbon electrode for trace determination of indium
    Xiang, CL
    Zou, YJ
    Xie, JJ
    Fei, XM
    Li, JH
    ANALYTICAL LETTERS, 2005, 38 (13) : 2045 - 2055
  • [48] Simultaneous determination of levodopa and tryptophan using a modified glassy carbon electrode
    Aflatoonian, Mohammad Reza
    Tajik, Somayeh
    Aflatoonian, Behnaz
    Ekrami-Kakhki, Mehri-Saddat
    Divsalar, Kouros
    Shoaie, Iran Sheikh
    Dourandish, Zahra
    Sheikhshoaie, Mahdieh
    EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (04): : 505 - 515
  • [49] Ruthenium Hexacyanoferrate (III) Modified Glassy Carbon Electrode for Determination of Captopril
    Dias, I. A. R. B.
    Costa, W. M.
    Cervini, P.
    Cavalheiro, E. T. G.
    Marques, A. L. B.
    ELECTROANALYSIS, 2016, 28 (09) : 2136 - 2142
  • [50] Mordant black modified glassy carbon electrode for the determination of methylene blue
    Bendany, Mohamed
    Ben Brahim, Khalid Ait
    El Hamdouni, Youssra
    Oumoussa, Hajar
    Labjar, Najoua
    Dahrouche, Abdelouahed
    Dalimi, Mohamed
    Omari, Mohamed
    Jebbari, Said
    Nasrellah, Hamid
    El Hajjaji, Souad
    EURO-MEDITERRANEAN JOURNAL FOR ENVIRONMENTAL INTEGRATION, 2024,