Determination of hydrogen sulfide in gasoline by Au nanoclusters modified glassy carbon electrode

被引:33
|
作者
Yang, Bo [1 ]
Wang, Shuqing [1 ]
Tian, Songbai [1 ]
Liu, Lingzhi [2 ]
机构
[1] Res Inst Petr Proc, Beijing 100083, Peoples R China
[2] Qinzhou Entry Exit Inspect & Quarantine Bur, Qinzhou 535000, Guangxi, Peoples R China
关键词
Hydrogen sulfide; Gasoline; Au; Nanocluster; Modified electrode; ELECTROCHEMICAL DETERMINATION; GAS SENSORS; SULFUR; ADSORPTION; NANOTUBES; OXIDATION; SYSTEM; SNO2;
D O I
10.1016/j.elecom.2009.04.007
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A promising hydrogen sulfide (H2S) sensor was prepared by electrodeposition of Au nanoclusters on glassy carbon electrode (GCE) and the surface structure was characterized by SEM and EDAX. These flower-like form Au nanoclusters, which were made up of highly dense clustering Au nanorods with an average diameter of 20 nm and length up to 80 nm, had an average size about 600 nm and uniformly distributed on the GCE surface. The electrocatalytic oxidation of H2S in gasoline was performed on this modified electrode, which had a satisfactory liner response to H2S in the range of 1-80 ppm and a detection limit of 0.45 ppm (s/n = 3). This sensor was sensitive, selective and stable. (C) 2009 Published by Elsevier B.V.
引用
收藏
页码:1230 / 1233
页数:4
相关论文
共 50 条
  • [1] Immobilization of enzymes on the nano-Au film modified glassy carbon electrode for the determination of hydrogen peroxide and glucose
    Lei, CX
    Wang, H
    Shen, GL
    Yu, RQ
    ELECTROANALYSIS, 2004, 16 (09) : 736 - 740
  • [2] Electrochemical determination of ascorbic acid using Cu sulfide modified glassy carbon electrode
    Pei L.Z.
    Lin N.
    Wei T.
    Liu H.D.
    Cai Z.Y.
    Surface Engineering and Applied Electrochemistry, 2016, 52 (6) : 565 - 571
  • [3] Electrochemical determination of hydrogen peroxide at a glassy carbon electrode modified with palladium nanoparticles
    Kitte, Shimeles Addisu
    Assresahegn, Birhanu Desalegn
    Soreta, Tesfaye Refera
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (05) : 701 - 711
  • [4] Determination of sodium sulfide based on electrochemiluminescence of rhodamine B at a SWNT modified glassy carbon electrode
    Liu, Fengyu
    Gao, Yulong
    Li, Wei
    Shao, Jiantao
    Meng, Yang
    RSC ADVANCES, 2014, 4 (32): : 16893 - 16898
  • [5] Amperometric Determination of Sulfide by Glassy Carbon Electrode Modified with Hemin Functionalized Reduced Graphene Oxide
    Cao, Xiaodong
    Gao, Jiaona
    Ye, Yingwang
    Wang, Pengfei
    Ding, Shun
    Ye, Yongkang
    Sun, Hanju
    ELECTROANALYSIS, 2016, 28 (01) : 140 - 144
  • [6] A modified glassy carbon electrode for hydrogen peroxide sensing
    Zheng, Cai-yun
    Chen, Shui-hong
    Shang, Yong-jia
    Li, Mao-guo
    ANNALI DI CHIMICA, 2007, 97 (11-12) : 1227 - 1235
  • [7] Development of a Glassy Carbon Electrode Modified with Graphene/Au Nanoparticles for Determination of Acetaminophen in Pharmaceutical Preparation
    Yingliang Wei
    Anting Wang
    Yuanyuan Liu
    Russian Journal of Electrochemistry, 2018, 54 : 1141 - 1147
  • [8] Development of a Glassy Carbon Electrode Modified with Graphene/Au Nanoparticles for Determination of Acetaminophen in Pharmaceutical Preparation
    Wei, Yingliang
    Wang, Anting
    Liu, Yuanyuan
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2018, 54 (12) : 1141 - 1147
  • [9] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [10] Polyglycine Modified Glassy Carbon Electrode for Ibuprofen Determination
    Matijasevic, Igor
    Kulizic, Mihajlo
    Bacetic, Ljubica
    Gavrilovic, Damjan
    Baosic, Rada
    Lolic, Aleksandar
    CHEMISTRYSELECT, 2023, 8 (24):