Numerical Study on Liquid-Return Characteristics in the Accumulator of the R290 Rotary Compressor

被引:1
|
作者
Lin, Jie [1 ]
Guo, Nini [1 ]
Wu, Jianhua [2 ]
Hong, Liangkun [3 ]
Jiang, Jianjiang [3 ]
机构
[1] Quzhou Univ, Coll Mech Engn, Key Lab Air Driven Equipment Technol Zhejiang Pro, Quzhou 324000, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
[3] Hongwuhuan Grp Co Ltd, Quzhou 324000, Peoples R China
基金
中国国家自然科学基金;
关键词
rotary compressor; liquid return; accumulator; R290; STARTUP CHARACTERISTICS; AIR-CONDITIONER; PERFORMANCE; SYSTEM;
D O I
10.3390/en15072469
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Liquid often exists in the accumulator of the rotary compressor during the process of startup or defrost of air-conditioning systems. Too much liquid entering the compressor cylinder would result in excessive pressure caused by the liquid compression, which is a great threat to the compressor. The liquid return through the liquid-return hole is the key to ensure the stable operation of the compressor. In this paper, the liquid-return characteristics in the liquid-return holes of the accumulator, including the mass-flow rate, liquid velocity and pressure difference between the liquid-return holes, during the startup process of the R290 rotary compressor are numerically investigated. The numerical simulation using the fluent volume of fluid (VOF) method was experimentally validated with the error of 1.55%. The comparison of liquid-return characteristics using different refrigerants is conducted. Effects of refrigerant solubility in the oil, refrigerant/oil-mixture type, liquid-return-hole diameter and compressor frequency on the liquid-return characteristics and liquid shape trough the liquid-return hole are discussed. The results show that the surface tension and viscosity of the liquid are the main factors affecting the liquid-return speed. The liquid-return rate of the refrigerant R290 is slower than that of other refrigerants R22 and R410A. The liquid-return rate increases with the increase in the compressor frequency. We conclude that for air-conditioning systems using R290 as refrigerant, increasing the number of return holes or the hole diameter is necessary to improve the liquid-return characteristics of the compressor. This research will provide theoretical guidance for the optimization of liquid return of rotary compressors using new refrigerants.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] THE SIMULATION OF THE LEAKING DISTRIBUTION CHARACTERISTICS OF R290 HOUSEHOLD AIR-CONDITIONER
    Cai, Dehua
    He, Guogeng
    Weiertang
    Lianghuang
    Tengjiaohai
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 133 - 145
  • [42] EXPERIMENTAL STUDY OF HYDROCARBON R290 IN WATER COOLER REFRIGERATION SYSTEM
    Choudhari, C. S.
    Sapali, S. N.
    JOURNAL OF THERMAL ENGINEERING, 2020, 6 (01): : 43 - 49
  • [43] Experimental study on hydrocarbon mixture refrigerant R600a/R290 in refrigerator
    Du, YP
    Lu, J
    Chen, H
    Sun, Y
    Yin, CX
    PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 1054 - 1057
  • [44] Numerical study of condensation heat transfer characteristics of R134a/ R290 and R134a/R1270 refrigerant blends as alternatives to replace R404A
    Zeng, Min-Qiang
    Zou, Lin-Geng
    Peng, Zhao-Rui
    Zhang, Xin-Rong
    Li, Jing
    APPLIED THERMAL ENGINEERING, 2024, 243
  • [45] Experimental study of the refrigeration cycle performance for the R744/R290 mixtures
    Niu, Baolian
    Zhang, Yufeng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (01): : 37 - 42
  • [46] A new structure and theoretical analysis on leakage and performance of an oil-free R290 rolling piston compressor
    Wu, JianHua
    Chen, Ang
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 49 : 110 - 118
  • [47] Simulation and experimental study on dynamic characteristics of R290 split heat pump during start-up
    Du, Yanjun
    Lin, Jie
    Wu, Jianhua
    Wang, Che
    Zhao, Tian
    Wu, Yuting
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [48] Detailed dynamic refrigerant migration characteristics in room air-conditioner with R290
    Liang Jierong
    Li Tingxun
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 108 - 116
  • [49] Effects of system control strategies on startup characteristics of R290 room air conditioners
    Wu, Jianhua
    Li, Jinbo
    Wang, Che
    Du, Yanjun
    Chen, Rui
    APPLIED THERMAL ENGINEERING, 2020, 172
  • [50] STUDY ON A R32/R290 BLEND AS REPLACEMENT FOR R410A IN HOUSEHOLD APPLICATIONS
    Tian, Q.
    Cai, D.
    Ren, L.
    Tang, W.
    Xie, Y.
    He, G.
    Liu, F.
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 216 - 223