Experimental study on hydrocarbon mixture refrigerant R600a/R290 in refrigerator

被引:0
|
作者
Du, YP [1 ]
Lu, J [1 ]
Chen, H [1 ]
Sun, Y [1 ]
Yin, CX [1 ]
机构
[1] Tianjin Commercial Univ, Tianjin 300134, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the experimental investigation on the Impacting of charging amount of R600a/R290 refrigerant on refrigerator performance and operating parameters. The results show that as the substitution of R12, the effective of R600a/R290 is similar to R12 cycle. The experimental results provided a good basis for improving the performance of alternative refrigerators.
引用
收藏
页码:1054 / 1057
页数:4
相关论文
共 50 条
  • [1] Measurements of the surface tension for R290, R600a and R290/R600a mixture
    Tanaka, Katsuyuki
    Higashi, Yukihiro
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (08): : 1368 - 1373
  • [2] Experimental investigation of R290/R600a mixture as an alternative to R134a in a domestic refrigerator
    Mohanraj, M.
    Jayaraj, S.
    Muraleedharan, C.
    Chandrasekar, P.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (05) : 1036 - 1042
  • [3] Research on flammability of R290/R134a, R600a/R134a and R600a/R290 refrigerant mixtures
    Cai, Dehua
    Hao, Zian
    Xu, Hao
    He, Guogeng
    International Journal of Refrigeration, 2022, 137 : 53 - 61
  • [4] Research on flammability of R290/R134a, R600a/R134a and R600a/R290 refrigerant mixtures
    Cai, Dehua
    Hao, Zian
    Xu, Hao
    He, Guogeng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 137 : 53 - 61
  • [5] Experimental Studies of a Domestic Refrigerator Using R290/R600a Zeotropic Blends
    Agrawal, Neeraj
    Patil, Shriganesh
    Nanda, Prasant
    INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 425 - 430
  • [6] Experimental Study on the Thermal Performance of R600a, R290 and R600a/R290 Mixtures in a Retrofit R134a Refrigeration System
    Ramathe, Teboho
    Huan, Zhongjie
    Mwesigye, Aggrey
    PROCEEDINGS OF THE 13TH CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY, 2015, : 178 - 186
  • [7] Exergy analysis of a domestic refrigerator using eco-friendly R290/R600a refrigerant mixture as an alternative to R134a
    Saravanakumar, R.
    Selladurai, V.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2014, 115 (01) : 933 - 940
  • [8] Exergy analysis of a domestic refrigerator using eco-friendly R290/R600a refrigerant mixture as an alternative to R134a
    R. Saravanakumar
    V. Selladurai
    Journal of Thermal Analysis and Calorimetry, 2014, 115 : 933 - 940
  • [9] Performance evaluation of a vapor injection refrigeration system using mixture refrigerant R290/R600a
    Hallak d'Angelo, Jose Vicente
    Aute, Vikrant
    Radermacher, Reinhard
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 65 : 194 - 208
  • [10] EXPERIMENTAL ANALYSIS OF MICROCHANNEL CONDENSER USING R134a AND DROP IN SUBSTITUTE HYDROCARBON MIXTURE OF R290 AND R600a
    Bhatkar, V. W.
    Kriplani, V. M.
    Awari, G. K.
    INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 2014, 10 : 1993 - 2002