BNCT: neutron dose evaluation using a Monte Carlo code

被引:2
|
作者
Rossi, F. [1 ]
Ono, K. [2 ]
Suzuki, M. [2 ]
Tanaka, H. [3 ]
Morigi, M. P. [1 ]
机构
[1] Univ Bologna, Dept Phys, I-40126 Bologna, Italy
[2] Kyoto Univ, Inst Res Reactor, Dept Radiat Oncol, Osaka 59004, Japan
[3] Kyoto Univ, Inst Res Reactor, Div Med Phys, Osaka 59004, Japan
来源
RADIATION EFFECTS AND DEFECTS IN SOLIDS | 2009年 / 164卷 / 5-6期
关键词
boron neutron capture therapy; MCNP simulation; tissue phantom;
D O I
10.1080/10420150902811680
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The purpose of this work is to analyze dose distribution inside tissues. To do this, we performed some MCNP simulations using the neutron flux obtained from the Kyoto University Reactor. We have tried to analyze the behavior of neutrons in different types of tissues in relation to their depth. We have found that the value of dose from neutron interaction with 10B depends not only on 10B concentration inside the tissues (a higher concentration produces a higher dose), but also on the tissue density. In fact, tissues with a density considerably different from that of water receive a lower dose. Another dose contribution is given by the presence of 14N inside tissues: this dose contribution is lower compared with the previous one; it is influenced both by the tissue density and the percentage of nitrogen inside the tissue. Finally, the delivered dose decreases very quickly after a depth of about 4cm, which implies that boron neutron capture therapy is not an effective therapy for the deepest tumors. However, there are some factors that can be taken into account to reach the deepest zone.
引用
收藏
页码:350 / 356
页数:7
相关论文
共 50 条
  • [41] TRIPOLI-3: A neutron/photon Monte Carlo transport code
    Nimal, JC
    Vergnaud, T
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 651 - 656
  • [42] Dose rate evaluation in a laboratory for prompt gamma neutron activation analysis by Monte Carlo simulation
    Lei, Haoyu
    Jia, Wenbao
    Hei, Daqian
    Gao, Youtao
    Cheng, Can
    Zhao, Dong
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 327 (01) : 477 - 483
  • [43] Monte Carlo Evaluation of Neutron Dose Equivalent Topatients Treated with Vertex Beams in IMPT and PSPT
    Titt, U.
    Grosshans, D.
    Sahoo, N.
    Zhu, X.
    Mohan, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [44] Simulation of Neutron Multiplicity Counting Based on Monte Carlo Code RMC
    Gou, Yuanhao
    Jia, Conglong
    Liu, Zhaoyuan
    Wang, Kan
    NUCLEAR SCIENCE AND ENGINEERING, 2024,
  • [45] MCNP - A GENERAL MONTE-CARLO CODE FOR NEUTRON AND PHOTON TRANSPORT
    FORSTER, RA
    GODFREY, TNK
    LECTURE NOTES IN PHYSICS, 1985, 240 : 33 - 55
  • [46] Modeling of a neutron irradiator using Monte Carlo
    Santos, Raphael F. G.
    Rebello, Wilson F.
    Estrada, Julio J. S.
    Medeiros, Marcos P. C.
    Silva, Ademir X.
    Souza, Edmilson M.
    Costa, Rogerio F.
    Barbosa, Caroline M.
    Braga, Kelmo L.
    Braz, Delson
    APPLIED RADIATION AND ISOTOPES, 2020, 165 (165)
  • [47] Effective dose evaluation for BNCT treatment in the epithermal neutron beam at THOR
    Wang, J. N.
    Huang, C. K.
    Tsai, W. C.
    Liu, Y. H.
    Jiang, S. H.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1850 - 1853
  • [48] A physically constrained Monte Carlo-Neural Network coupling algorithm for BNCT dose calculation
    Wang, Yongquan
    Du, Junliang
    Lin, Huan
    Guan, Xingcai
    Zhang, Lu
    Li, Jinyang
    Gu, Long
    MEDICAL PHYSICS, 2024, 51 (06) : 4524 - 4535
  • [49] Mix mesh sizes arithmetic research of BNCT dose rate calculations by Monte Carlo method
    Qiu, YH
    Deng, L
    Ying, YJ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (06): : 669 - 674
  • [50] Monte Carlo dose calculation for HDR brachytherapy source using EGS5 code
    Badry, H.
    Oufni, L.
    Ouabi, H.
    Hirayama, H.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 150 : 76 - 81