BNCT: neutron dose evaluation using a Monte Carlo code

被引:2
|
作者
Rossi, F. [1 ]
Ono, K. [2 ]
Suzuki, M. [2 ]
Tanaka, H. [3 ]
Morigi, M. P. [1 ]
机构
[1] Univ Bologna, Dept Phys, I-40126 Bologna, Italy
[2] Kyoto Univ, Inst Res Reactor, Dept Radiat Oncol, Osaka 59004, Japan
[3] Kyoto Univ, Inst Res Reactor, Div Med Phys, Osaka 59004, Japan
来源
RADIATION EFFECTS AND DEFECTS IN SOLIDS | 2009年 / 164卷 / 5-6期
关键词
boron neutron capture therapy; MCNP simulation; tissue phantom;
D O I
10.1080/10420150902811680
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The purpose of this work is to analyze dose distribution inside tissues. To do this, we performed some MCNP simulations using the neutron flux obtained from the Kyoto University Reactor. We have tried to analyze the behavior of neutrons in different types of tissues in relation to their depth. We have found that the value of dose from neutron interaction with 10B depends not only on 10B concentration inside the tissues (a higher concentration produces a higher dose), but also on the tissue density. In fact, tissues with a density considerably different from that of water receive a lower dose. Another dose contribution is given by the presence of 14N inside tissues: this dose contribution is lower compared with the previous one; it is influenced both by the tissue density and the percentage of nitrogen inside the tissue. Finally, the delivered dose decreases very quickly after a depth of about 4cm, which implies that boron neutron capture therapy is not an effective therapy for the deepest tumors. However, there are some factors that can be taken into account to reach the deepest zone.
引用
收藏
页码:350 / 356
页数:7
相关论文
共 50 条
  • [21] COMMISSIONING OF AN OPEN-SOURCE MONTE CARLO CODE FOR LOW DOSE RATE BRACHYTHERAPY DOSE EVALUATION
    Moghadam, Narjes
    Zhang, Claire
    Ouellet, Samuel
    McKeown, Dakota
    Cygler, Joanna
    Hilts, Michelle
    Beaulieu, Luc
    Thomson, Rowan
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S56 - S57
  • [22] Evaluation of Accuracy and Performance of a Fast Monte Carlo Code for Dose Calculation in Proton Therapy
    Jabbari, K.
    Roayaei, M.
    Saeedi, A.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S40 - S40
  • [23] Monte-Carlo calculations for the development of a BNCT neutron source at the Kyiv Research Reactor
    Gritzay, OO
    Kalchenko, OI
    Klimova, NA
    Razbudey, VF
    Sanzhur, AI
    Binney, SE
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 869 - 873
  • [24] Monte Carlo simulation of prompt gamma neutron activation analysis using MCNP code
    Evans, CJ
    Ryde, SJS
    Hancock, DA
    Al-Agel, F
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 541 - 543
  • [25] Dose evaluation in a portable D–T neutron generator facility by Monte Carlo method
    Cong Li
    Shiwei Jing
    Hui Xue
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 324 : 533 - 539
  • [26] Investigation of Tissue Components Impacts on Dose Enhancement Factor Using Monte Carlo Code
    Al-Suhbani, M. N.
    Baghous, N. E. H.
    Serag, S.
    El Mahjoub, C.
    Ait-Mlouk, L.
    Zia, A.
    Hamid, B.
    Azougagh, M.
    ATOM INDONESIA, 2024, 50 (01) : 1 - 8
  • [27] The Monte Carlo code MCPTV-Monte Carlo dose calculation in radiation therapy with carbon ions
    Karg, Juergen
    Speer, Stefan
    Schmidt, Manfred
    Mueller, Reinhold
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (13): : 3917 - 3936
  • [28] Proposal of shutdown dose estimation method by Monte Carlo code
    Valenza, D
    Iida, H
    Plenteda, R
    Santoro, RT
    FUSION ENGINEERING AND DESIGN, 2001, 55 (04) : 411 - 418
  • [29] CARLO DTS - A MONTE-CARLO CODE FOR THE DUAL THIN SCINTILLATOR NEUTRON DETECTOR
    DIAS, MS
    JOHNSON, RG
    PROGRESS IN NUCLEAR ENERGY, 1990, 24 (1-3) : 295 - 304
  • [30] Design and dosimetric evaluation of beam shaping assembly for BNCT of compact D-T neutron generator by Monte Carlo simulation
    Sahoo, G. S.
    Sharma, S. D.
    Tripathy, S. P.
    Bandyopadhyay, T.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (01):