Percutaneous Left Ventricular Assist Devices in Ventricular Tachycardia Ablation Multicenter Experience

被引:74
|
作者
Reddy, Yeruva Madhu [1 ,2 ]
Chinitz, Larry [3 ]
Mansour, Moussa [4 ]
Bunch, T. Jared [5 ]
Mahapatra, Srijoy [6 ]
Swarup, Vijay [7 ]
Di Biase, Luigi [8 ]
Bommana, Sudharani [1 ,2 ]
Atkins, Donita [1 ,2 ]
Tung, Roderick [9 ]
Shivkumar, Kalyanam [9 ]
Burkhardt, J. David [8 ]
Ruskin, Jeremy [4 ]
Natale, Andrea [8 ]
Lakkireddy, Dhanunjaya [1 ,2 ]
机构
[1] Univ Kansas Hosp, Cardiovasc Res Inst, Div Cardiovasc Dis, Kansas City, KS 66160 USA
[2] Univ Kansas, Med Ctr, Kansas City, KS 66103 USA
[3] NYU, Sch Med, Div Cardiol, New York, NY USA
[4] Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
[5] Intermt Heart Inst, Salt Lake City, UT USA
[6] St Jude Med, St Paul, MN USA
[7] Arizona Heart Rhythm Ctr, Phoenix, AZ USA
[8] Texas Cardiac Arrhythmia Inst, Austin, TX USA
[9] UCLA Med Ctr, Div Cardiol, Los Angeles, CA USA
来源
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY | 2014年 / 7卷 / 02期
关键词
catheter ablation; intra-aortic balloon pumping; tachycardia; ventricular; CATHETER ABLATION; MYOCARDIAL-INFARCTION; SUPPORT;
D O I
10.1161/CIRCEP.113.000548
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Data on relative safety, efficacy, and role of different percutaneous left ventricular assist devices for hemodynamic support during the ventricular tachycardia (VT) ablation procedure are limited. Methods and Results We performed a multicenter, observational study from a prospective registry including all consecutive patients (N=66) undergoing VT ablation with a percutaneous left ventricular assist devices in 6 centers in the United States. Patients with intra-aortic balloon pump (IABP group; N=22) were compared with patients with either an Impella or a TandemHeart device (non-IABP group; N=44). There were no significant differences in the baseline characteristics between both the groups. In non-IABP group (1) more patients could undergo entrainment/activation mapping (82% versus 59%; P=0.046), (2) more number of unstable VTs could be mapped and ablated per patient (1.050.78 versus 0.32 +/- 0.48; P<0.001), (3) more number of VTs could be terminated by ablation (1.59 +/- 1.0 versus 0.91 +/- 0.81; P=0.007), and (4) fewer VTs were terminated with rescue shocks (1.9 +/- 2.2 versus 3.0 +/- 1.5; P=0.049) when compared with IABP group. Complications of the procedure trended to be more in the non-IABP group when compared with those in the IABP group (32% versus 14%; P=0.143). Intermediate term outcomes (mortality and VT recurrence) during 12 +/- 5-month follow-up were not different between both groups. Left ventricular ejection fraction 15% was a strong and independent predictor of in-hospital mortality (53% versus 4%; P<0.001). Conclusions Impella and TandemHeart use in VT ablation facilitates extensive activation mapping of several unstable VTs and requires fewer rescue shocks during the procedure when compared with using IABP.
引用
收藏
页码:244 / 250
页数:7
相关论文
共 50 条
  • [41] Left ventricular assist devices
    Birks, E. J.
    HEART, 2010, 96 (01) : 63 - 71
  • [42] Pulsed Field Ablation for Refractory Ventricular Arrhythmias in Patients With Left Ventricular Assist Devices
    Benali, Karim
    Monaco, Cinzia
    Jais, Pierre
    Vlachos, Konstantinos
    Kneizeh, Kinan
    Menes, Roberto
    Yokoyama, Masaaki
    Kowalewski, Christopher
    Da Costa, Antoine
    Hocini, Meleze
    Ploux, Sylvain
    Haissaguerre, Michel
    Sacher, Frederic
    Duchateau, Josselin
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2024, 10 (12) : 2775 - 2783
  • [43] Left ventricular assist devices
    Gwyn, Jennifer C., V
    JOURNAL OF THE INTENSIVE CARE SOCIETY, 2020, 21 (04) : 355 - 358
  • [44] Response to the Editor: Percutaneous left ventricular assist device support during ablation of ventricular tachycardia: A meta-analysis of current evidence
    Luni, Faraz Khan
    Zungsontiporn, Nath
    Link, Mark S.
    Joglar, Jose A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (10) : 2185 - 2186
  • [45] Hybrid ablation of haemodynamically unstable ventricular tachycardia using a transabdominal minimally-invasive approach and percutaneous left ventricular assist device
    Buchta, Piotr
    Zembala, Michal
    Hawranek, Michal
    Zembala, Marian
    Gasior, Mariusz
    KARDIOLOGIA POLSKA, 2017, 75 (11) : 1210 - 1210
  • [46] Contemporary Experience with Percutaneous and Surgical Right Ventricular Assist Devices
    Um, J.
    Ryan, T.
    Moulton, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S229 - S230
  • [47] Usability of Ventricular Assist Devices in Daily Experience: A Multicenter Study
    Schima, Heinrich
    Schloeglhofer, Thomas
    Dohna, Renata Zu
    Drews, Thorsten
    Morshuis, Michiel
    Roefe, Daniela
    Schmitto, Jan D.
    Strueber, Martin
    Zimpfer, Daniel
    ARTIFICIAL ORGANS, 2014, 38 (09) : 751 - 760
  • [48] Robotic catheter ablation of left ventricular tachycardia: initial experience
    Valderrabano, Miguel
    Dave, Amish S.
    Baez-Escudero, Jose L.
    Rami, Tapan
    HEART RHYTHM, 2011, 8 (12) : 1837 - 1846
  • [49] Early experience with a percutaneous left ventricular assist device (TandemHeart)
    Windecker, S
    Watson, S
    Carrel, T
    Schmidli, J
    Takala, J
    Hullin, R
    Molhacsi, P
    Meier, B
    EUROPEAN HEART JOURNAL, 2004, 25 : 580 - 581
  • [50] Catheter Ablation for Recurrent Ventricular Tachycardia After Implantation of a Left Ventricular Assist Device: A Interdisciplinary Approach
    Garbade, Jens
    Fischer, Julia
    Meyer, Anna
    Lehmann, Sven
    Arya, Arash
    Hindricks, Gerhard
    Mohr, Friedrich-Wilhelm
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (08) : S114 - S114