Percutaneous Left Ventricular Assist Devices in Ventricular Tachycardia Ablation Multicenter Experience

被引:74
|
作者
Reddy, Yeruva Madhu [1 ,2 ]
Chinitz, Larry [3 ]
Mansour, Moussa [4 ]
Bunch, T. Jared [5 ]
Mahapatra, Srijoy [6 ]
Swarup, Vijay [7 ]
Di Biase, Luigi [8 ]
Bommana, Sudharani [1 ,2 ]
Atkins, Donita [1 ,2 ]
Tung, Roderick [9 ]
Shivkumar, Kalyanam [9 ]
Burkhardt, J. David [8 ]
Ruskin, Jeremy [4 ]
Natale, Andrea [8 ]
Lakkireddy, Dhanunjaya [1 ,2 ]
机构
[1] Univ Kansas Hosp, Cardiovasc Res Inst, Div Cardiovasc Dis, Kansas City, KS 66160 USA
[2] Univ Kansas, Med Ctr, Kansas City, KS 66103 USA
[3] NYU, Sch Med, Div Cardiol, New York, NY USA
[4] Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
[5] Intermt Heart Inst, Salt Lake City, UT USA
[6] St Jude Med, St Paul, MN USA
[7] Arizona Heart Rhythm Ctr, Phoenix, AZ USA
[8] Texas Cardiac Arrhythmia Inst, Austin, TX USA
[9] UCLA Med Ctr, Div Cardiol, Los Angeles, CA USA
来源
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY | 2014年 / 7卷 / 02期
关键词
catheter ablation; intra-aortic balloon pumping; tachycardia; ventricular; CATHETER ABLATION; MYOCARDIAL-INFARCTION; SUPPORT;
D O I
10.1161/CIRCEP.113.000548
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Data on relative safety, efficacy, and role of different percutaneous left ventricular assist devices for hemodynamic support during the ventricular tachycardia (VT) ablation procedure are limited. Methods and Results We performed a multicenter, observational study from a prospective registry including all consecutive patients (N=66) undergoing VT ablation with a percutaneous left ventricular assist devices in 6 centers in the United States. Patients with intra-aortic balloon pump (IABP group; N=22) were compared with patients with either an Impella or a TandemHeart device (non-IABP group; N=44). There were no significant differences in the baseline characteristics between both the groups. In non-IABP group (1) more patients could undergo entrainment/activation mapping (82% versus 59%; P=0.046), (2) more number of unstable VTs could be mapped and ablated per patient (1.050.78 versus 0.32 +/- 0.48; P<0.001), (3) more number of VTs could be terminated by ablation (1.59 +/- 1.0 versus 0.91 +/- 0.81; P=0.007), and (4) fewer VTs were terminated with rescue shocks (1.9 +/- 2.2 versus 3.0 +/- 1.5; P=0.049) when compared with IABP group. Complications of the procedure trended to be more in the non-IABP group when compared with those in the IABP group (32% versus 14%; P=0.143). Intermediate term outcomes (mortality and VT recurrence) during 12 +/- 5-month follow-up were not different between both groups. Left ventricular ejection fraction 15% was a strong and independent predictor of in-hospital mortality (53% versus 4%; P<0.001). Conclusions Impella and TandemHeart use in VT ablation facilitates extensive activation mapping of several unstable VTs and requires fewer rescue shocks during the procedure when compared with using IABP.
引用
收藏
页码:244 / 250
页数:7
相关论文
共 50 条
  • [11] Hemodynamic Implications of Transseptal Access for Ventricular Tachycardia Ablation in Patients With Left Ventricular Assist Devices
    Curtis, Brett
    Deshmukh, Amrish
    Larson, John D.
    Ghanbari, Hamid
    Ghannam, Michael
    Latchamsetty, Rakesh
    Bogun, Frank
    Liang, Jackson
    CIRCULATION, 2023, 148
  • [12] Positional ventricular tachycardia in left ventricular assist device: a new frontier in ventricular tachycardia ablation
    Acou, Willem-Jan M. F.
    Bertagnolli, Livio
    Hindricks, Gerhard
    Arya, Arash
    EUROPEAN HEART JOURNAL, 2014, 35 (02) : 65 - 65
  • [13] Endocardial catheter ablation of ventricular tachycardia in patients with ventricular assist devices
    Dandamudi, Gopi
    Ghumman, Waqas S.
    Das, Mithilesh K.
    Miller, John M.
    HEART RHYTHM, 2007, 4 (09) : 1165 - 1169
  • [14] Outcomes in Ventricular Tachycardia Ablation in Left Ventricular Assist Device Patients
    Shah, Nischay
    Khalid, Yaser
    Umrani, Rohan
    Amin, Hiral
    Khalid, Fizan
    Dasu, Neethi
    Dasu, Kirti
    Pancholy, Samir
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B152 - B153
  • [15] Ventricular Tachycardia in Patients with Continuous Flow Left Ventricular Assist Devices: A Single Center Experience
    Shivamurthy, Poojita
    Ganga, Harsha
    Ingrassia, Joseph
    Slim, Hanna B.
    Radojevic, Joseph
    Gluck, Jason
    Kluger, Jeffrey
    CIRCULATION, 2014, 130
  • [16] Safety and hemodynamic implications of transseptal access for ventricular tachycardia ablation in patients with left ventricular assist devices
    Curtis, Brett
    Deshmukh, Amrish
    Larson, John
    Ghanbari, Hamid
    Ghannam, Michael
    Crawford, Thomas C.
    Latchamsetty, Rakesh
    Pagani, Francis D.
    Bogun, Frank
    Liang, Jackson J.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (6) : 1319 - 1321
  • [17] Assessing outcomes following catheter ablation of ventricular tachycardia in patients with durable left ventricular assist devices
    Olarte, N.
    Vincent, L.
    Ebner, B.
    Grant, J.
    Maning, J.
    Hernandez, R.
    Rivera-Rodriguez, B.
    Giraldo, M.
    Grazette, L.
    EUROPEAN HEART JOURNAL, 2022, 43 : 692 - 692
  • [18] Percutaneous Deactivation of Left Ventricular Assist Devices
    Albulushi, Arif
    Goldsweig, Andrew M.
    Stoller, Douglas
    Delaney, Jeffrey W.
    Um, John
    Lowes, Brian
    Zolty, Ronald
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (03) : 467 - 472
  • [19] Endocardial Catheter Based Ablation of Ventricular Tachycardia in Patients with Ventricular Assist Devices
    Winner, M. W.
    Daoud, E. G.
    Ravi, Y.
    Ackers, J.
    Emani, S.
    Firstenberg, M.
    Sai-Sudhaker, C. B.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S253 - S254
  • [20] Efficacy and Safety of Ablation versus Medication for Treatment of Recurrent Ventricular Tachycardia in Patients With Left Ventricular Assist Devices
    Debenham, Rachel L.
    Cotter, Ryan
    Tumolo, Alexis Z.
    Sandhu, Amneet
    Aleong, Ryan G.
    Borne, Ryan
    Fleeman, Blake
    Mantini, Nicholas
    Miller, Brian
    Chang, Shu
    Brieke, Andreas
    Butcher, Eric
    Tompkins, Christine
    Zipse, Matthew
    Tzou, Wendy S.
    CIRCULATION, 2019, 140