Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures

被引:76
|
作者
Norton, Robert P. [1 ]
Milne, Edward L. [2 ]
Kaimrajh, David N. [2 ]
Eismont, Frank J. [1 ]
Latta, Loren L. [1 ,2 ]
Williams, Seth K. [3 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Orthopaed Surg, Miami, FL 33101 USA
[2] Mt Sinai Med Ctr, Max Biedermann Inst Biomech, Dept Res, Miami Beach, FL 33140 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Orthopaed & Rehabil, Madison, WI 53705 USA
来源
SPINE JOURNAL | 2014年 / 14卷 / 08期
关键词
Short-segment fusion; Axial load fracture; Pedicle screw instrumentation; Spine fracture biomechanics; Spine fracture fixation; Thoracolumbar instrumentation; BURST FRACTURES; POSTERIOR INSTRUMENTATION; SPINE FRACTURES; IN-VIVO; INTERNAL-FIXATION; LUMBAR FUSION; LONG; ADJACENT; ANTERIOR; MODEL;
D O I
10.1016/j.spinee.2014.01.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Conventionally, short-segment fusion involves instrumentation of one healthy vertebra above and below the injured vertebra, skipping the injured level. This short-segment construct places less surgical burden on the patient compared with long-segment constructs, but is less stable biomechanically, and thus has resulted in clinical failures. The addition of two screws placed in the fractured vertebral body represents an attempt to improve the construct stiffness without sacrificing the benefits of short-segment fusion. PURPOSE: To determine the biomechanical differences between four-and six-screw short-segment constructs for the operative management of an unstable L1 fracture. STUDY DESIGN: Biomechanical study of instrumentation in vertebral body cadaveric models simulating an L1 axial load injury pattern. METHODS: Thirteen intact spinal segments from T12 to L2 were prepared from fresh-frozen cadaver spines. An axial load fracture of at least 50% vertebral body height was produced at L1 and then instrumented with pedicle screws. Specimens were evaluated in terms of construct stiffness, motion, and rod strain. Two conditions were tested: a four-screw construct with no screws at the L1 fractured body (4S) and a six-screw construct with screws at all levels (6S). The two groups were compared statistically by paired Student t test. RESULTS: The mean stiffness in flexion-extension was increased 31% (p < .03) with the addition of the two pedicle screws in L1. Relative motion in terms of vertical and axial rotations was not significantly different between the two groups. The L1-L2 rod strain was significantly increased in the six-screw construct compared with the four-screw construct (p < .001). CONCLUSIONS: In a cadaveric L1 axial load fracture model, a six-screw construct with screws in the fractured level is more rigid than a four-screw construct that skips the injured vertebral body. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1734 / 1739
页数:6
相关论文
共 50 条
  • [41] Short-Segment Fixation With Percutaneous Pedicle Screws in the Treatment of Unstable Thoracolumbar Vertebral Body Fractures
    Sahai, Nikil
    Faloon, Michael J.
    Dunn, Conor J.
    Issa, Kimona
    Sinha, Kumar
    Hwang, Ki Soo
    Emami, Arash
    ORTHOPEDICS, 2018, 41 (06) : E802 - E806
  • [42] Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis
    Li, Changqing
    Zhou, Yue
    Wang, Hongwei
    Liu, Jun
    Xiang, Liangbi
    PLOS ONE, 2014, 9 (06):
  • [43] IN REPLY TO THE LETTER TO THE EDITOR REGARDING "RESTORATION OF ANTERIOR VERTEBRAL HEIGHT BY SHORT-SEGMENT PEDICLE SCREW FIXATION WITH SCREWING OF FRACTURED VERTEBRA FOR THE TREATMENT OF UNSTABLE THORACOLUMBAR FRACTURES"
    Kanat, Ayhan
    Ozdemir, Bulent
    WORLD NEUROSURGERY, 2017, 101 : 793 - 793
  • [44] Unilateral Pediculectomy and Reduction with Short-Segment Pedicle Screw Fixation for Thoracolumbar Burst Fracture: A Case Series
    Lee, Sang Hyub
    Lee, Subum
    Jang, Sun Woo
    Shin, Hong Kyung
    Kim, Dong-Hwan
    Kang, Dong Ho
    Jeon, Sang Ryong
    Roh, Sung Woo
    Park, Jin Hoon
    WORLD NEUROSURGERY, 2024, 183 : E116 - E126
  • [45] Posterior short segment pedicle screw fixation and TLIF for the treatment of unstable thoracolumbar/lumbar fracture
    Ling Wang
    Jianjun Li
    Hong Wang
    Qun Yang
    Decheng Lv
    Weiguo Zhang
    Kai Tang
    Limin Shang
    Changming Jiang
    Chunming Wu
    Kai Ma
    Bo Wang
    Yang Liu
    Rui Zhang
    Xianping Shang
    Depeng Kou
    Xunyuan Jia
    Xianglong Yang
    Yilong Tang
    Meng Zhang
    Pengrui Wang
    Yan Xu
    Shijin Wang
    BMC Musculoskeletal Disorders, 15
  • [46] Posterior short segment pedicle screw fixation and TLIF for the treatment of unstable thoracolumbar/lumbar fracture
    Wang, Ling
    Li, Jianjun
    Wang, Hong
    Yang, Qun
    Lv, Decheng
    Zhang, Weiguo
    Tang, Kai
    Shang, Limin
    Jiang, Changming
    Wu, Chunming
    Ma, Kai
    Wang, Bo
    Liu, Yang
    Zhang, Rui
    Shang, Xianping
    Kou, Depeng
    Jia, Xunyuan
    Yang, Xianglong
    Tang, Yilong
    Zhang, Meng
    Wang, Pengrui
    Xu, Yan
    Wang, Shijin
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [47] Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience
    Afzal, Suhail
    Akbar, Saleem
    Dhar, Shabir A.
    EUROPEAN SPINE JOURNAL, 2008, 17 (03) : 336 - 341
  • [48] Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience
    Suhail Afzal
    Saleem Akbar
    Shabir A. Dhar
    European Spine Journal, 2008, 17 : 336 - 341
  • [49] Retrospective analysis of treatment of thoracolumbar burst fracture using mono-segment pedicle instrumentation compared with short-segment pedicle instrumentation
    Xilei Li
    Yiqun Ma
    Jian Dong
    Xiao-gang Zhou
    Juan Li
    European Spine Journal, 2012, 21 : 2034 - 2042
  • [50] Retrospective analysis of treatment of thoracolumbar burst fracture using mono-segment pedicle instrumentation compared with short-segment pedicle instrumentation
    Li, Xilei
    Ma, Yiqun
    Dong, Jian
    Zhou, Xiao-gang
    Li, Juan
    EUROPEAN SPINE JOURNAL, 2012, 21 (10) : 2034 - 2042