Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures

被引:76
|
作者
Norton, Robert P. [1 ]
Milne, Edward L. [2 ]
Kaimrajh, David N. [2 ]
Eismont, Frank J. [1 ]
Latta, Loren L. [1 ,2 ]
Williams, Seth K. [3 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Orthopaed Surg, Miami, FL 33101 USA
[2] Mt Sinai Med Ctr, Max Biedermann Inst Biomech, Dept Res, Miami Beach, FL 33140 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Orthopaed & Rehabil, Madison, WI 53705 USA
来源
SPINE JOURNAL | 2014年 / 14卷 / 08期
关键词
Short-segment fusion; Axial load fracture; Pedicle screw instrumentation; Spine fracture biomechanics; Spine fracture fixation; Thoracolumbar instrumentation; BURST FRACTURES; POSTERIOR INSTRUMENTATION; SPINE FRACTURES; IN-VIVO; INTERNAL-FIXATION; LUMBAR FUSION; LONG; ADJACENT; ANTERIOR; MODEL;
D O I
10.1016/j.spinee.2014.01.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Conventionally, short-segment fusion involves instrumentation of one healthy vertebra above and below the injured vertebra, skipping the injured level. This short-segment construct places less surgical burden on the patient compared with long-segment constructs, but is less stable biomechanically, and thus has resulted in clinical failures. The addition of two screws placed in the fractured vertebral body represents an attempt to improve the construct stiffness without sacrificing the benefits of short-segment fusion. PURPOSE: To determine the biomechanical differences between four-and six-screw short-segment constructs for the operative management of an unstable L1 fracture. STUDY DESIGN: Biomechanical study of instrumentation in vertebral body cadaveric models simulating an L1 axial load injury pattern. METHODS: Thirteen intact spinal segments from T12 to L2 were prepared from fresh-frozen cadaver spines. An axial load fracture of at least 50% vertebral body height was produced at L1 and then instrumented with pedicle screws. Specimens were evaluated in terms of construct stiffness, motion, and rod strain. Two conditions were tested: a four-screw construct with no screws at the L1 fractured body (4S) and a six-screw construct with screws at all levels (6S). The two groups were compared statistically by paired Student t test. RESULTS: The mean stiffness in flexion-extension was increased 31% (p < .03) with the addition of the two pedicle screws in L1. Relative motion in terms of vertical and axial rotations was not significantly different between the two groups. The L1-L2 rod strain was significantly increased in the six-screw construct compared with the four-screw construct (p < .001). CONCLUSIONS: In a cadaveric L1 axial load fracture model, a six-screw construct with screws in the fractured level is more rigid than a four-screw construct that skips the injured vertebral body. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1734 / 1739
页数:6
相关论文
共 50 条
  • [31] Evaluation of vertebral shortening and interbody fusion with short segment pedicle screw fixation for unstable thoracolumbar fractures
    Sural, Sumit
    Goyal, Arpit
    Garg, Rahul
    Singh, Ashwani
    Kashyap, Abhishek
    Arora, Sumit
    JOURNAL OF ORTHOPAEDICS, 2023, 37 : 15 - 21
  • [32] Comparison of Surgical Outcomes Between Short-Segment Open and Percutaneous Pedicle Screw Fixation Techniques for Thoracolumbar Fractures
    Fu, Zhiguo
    Zhang, Xi
    Shi, Yaohua
    Dong, Qirong
    MEDICAL SCIENCE MONITOR, 2016, 22 : 3177 - 3185
  • [33] The effect of the size of pedicle screw on the long-term radiological and clinical results of short-segment posterior instrumentation in the management of thoracolumbar vertebral fractures
    Ozturk, Anil Murat
    Suer, Onur
    Aydemir, Selahaddin
    Kilicli, Buenyamin
    Akcali, Omer
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (01) : 20 - 26
  • [34] Short segment pedicle screw instrumentation with an index level screw and cantilevered hyperlordotic reduction in the treatment of type-A fractures of the thoracolumbar spine
    Kose, K. C.
    Inanmaz, M. E.
    Isik, C.
    Basar, H.
    Caliskan, I.
    Bal, E.
    BONE & JOINT JOURNAL, 2014, 96B (04): : 541 - 547
  • [35] Predictive Factors for a Kyphosis Recurrence Following Short-Segment Pedicle Screw Fixation Including Fractured Vertebral Body in Unstable Thoracolumbar Burst Fractures
    Kim, Gun-Woo
    Jang, Jae-Won
    Hur, Hyuk
    Lee, Jung-Kil
    Kim, Jae-Hyoo
    Kim, Soo-Han
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2014, 56 (03) : 230 - 236
  • [36] Short-segment pedicle instrumentation - Biomechanical analysis of supplemental hook fixation
    Chiba, M
    McLain, RF
    Yerby, SA
    Moseley, TA
    Smith, TS
    Benson, DR
    SPINE, 1996, 21 (03) : 288 - 294
  • [37] Biomechanical characteristics of hybrid hook-screw constructs in short-segment thoracic fixation
    Jones, G. Alexander
    Kayanja, Mark
    Milks, Ryan
    Lieberman, Isador
    SPINE, 2008, 33 (02) : 173 - 177
  • [38] A Letter to the Editor regarding "Restoration of Anterior Vertebral Height by Short-Segment Pedicle Screw Fixation with Screwing of Fractured Vertebra for the Treatment of Unstable Thoracolumbar Fractures"
    Ozbek, Zuhtu
    Ozkara, Emre
    WORLD NEUROSURGERY, 2017, 101 : 792 - 792
  • [39] Comparison of Posterior Short-segment Pedicle Screw Fixation with or without Fusion in Thoracolumbar Burst Fracture
    Bharadwaj, Arvind
    Bhardwaj, Akshay Rakeshmohan
    Sharma, Gaurav Mahesh
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (12) : RC01 - RC04
  • [40] Comparison of Short Segment Pedicle Screw Fixation Including the Fractured Vertebra Versus Long Segment Fixation in Thoracolumbar Fractures
    Cretin, Engin
    Oner, Ali