Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures

被引:76
|
作者
Norton, Robert P. [1 ]
Milne, Edward L. [2 ]
Kaimrajh, David N. [2 ]
Eismont, Frank J. [1 ]
Latta, Loren L. [1 ,2 ]
Williams, Seth K. [3 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Orthopaed Surg, Miami, FL 33101 USA
[2] Mt Sinai Med Ctr, Max Biedermann Inst Biomech, Dept Res, Miami Beach, FL 33140 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Orthopaed & Rehabil, Madison, WI 53705 USA
来源
SPINE JOURNAL | 2014年 / 14卷 / 08期
关键词
Short-segment fusion; Axial load fracture; Pedicle screw instrumentation; Spine fracture biomechanics; Spine fracture fixation; Thoracolumbar instrumentation; BURST FRACTURES; POSTERIOR INSTRUMENTATION; SPINE FRACTURES; IN-VIVO; INTERNAL-FIXATION; LUMBAR FUSION; LONG; ADJACENT; ANTERIOR; MODEL;
D O I
10.1016/j.spinee.2014.01.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Conventionally, short-segment fusion involves instrumentation of one healthy vertebra above and below the injured vertebra, skipping the injured level. This short-segment construct places less surgical burden on the patient compared with long-segment constructs, but is less stable biomechanically, and thus has resulted in clinical failures. The addition of two screws placed in the fractured vertebral body represents an attempt to improve the construct stiffness without sacrificing the benefits of short-segment fusion. PURPOSE: To determine the biomechanical differences between four-and six-screw short-segment constructs for the operative management of an unstable L1 fracture. STUDY DESIGN: Biomechanical study of instrumentation in vertebral body cadaveric models simulating an L1 axial load injury pattern. METHODS: Thirteen intact spinal segments from T12 to L2 were prepared from fresh-frozen cadaver spines. An axial load fracture of at least 50% vertebral body height was produced at L1 and then instrumented with pedicle screws. Specimens were evaluated in terms of construct stiffness, motion, and rod strain. Two conditions were tested: a four-screw construct with no screws at the L1 fractured body (4S) and a six-screw construct with screws at all levels (6S). The two groups were compared statistically by paired Student t test. RESULTS: The mean stiffness in flexion-extension was increased 31% (p < .03) with the addition of the two pedicle screws in L1. Relative motion in terms of vertical and axial rotations was not significantly different between the two groups. The L1-L2 rod strain was significantly increased in the six-screw construct compared with the four-screw construct (p < .001). CONCLUSIONS: In a cadaveric L1 axial load fracture model, a six-screw construct with screws in the fractured level is more rigid than a four-screw construct that skips the injured vertebral body. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1734 / 1739
页数:6
相关论文
共 50 条
  • [1] Comment on the biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures
    Bakhsheshian, Joshua
    Dahdaleh, Nader S.
    Patwardhan, Anivash G.
    Smith, Zachary A.
    SPINE JOURNAL, 2014, 14 (08): : 1810 - 1811
  • [2] Posterior short-segment fixation in thoracolumbar unstable burst fractures - Transpedicular grafting or six-screw construct?
    Liao, Jen-Chung
    Fan, Kuo-Fon
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2017, 153 : 56 - 63
  • [3] Biomechanics of in situ rod contouring of short-segment pedicle screw instrumentation in the thoracolumbar spine
    Voor, MJ
    Roberts, CS
    Rose, SM
    Glassman, SD
    JOURNAL OF SPINAL DISORDERS, 1997, 10 (02): : 106 - 116
  • [4] Comparing the efficacy of short-segment pedicle screw instrumentation with and without intermediate screws for treating unstable thoracolumbar fractures
    Ye, Conglin
    Luo, Zhiping
    Yu, Xiaolong
    Liu, Hucheng
    Zhang, Bin
    Dai, Min
    MEDICINE, 2017, 96 (34)
  • [5] Long-Segment Versus Short-Segment Pedicle Screw Fixation Including Fractured Vertebrae for the Management of Unstable Thoracolumbar Burst Fractures
    Choudhury, Abdullah Al Mamun
    Alam, Shah
    Jonayed, Sharif
    Dastagir, O. Z. M.
    Jahan, Sarwar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [6] Efficacy of Vertebroplasty in Short-Segment Pedicle Screw Fixation of Thoracolumbar Fractures: A Meta-Analysis
    Zhang, Gen-Ai
    Zhang, Wen-Ping
    Chen, Ying-Chun
    Hou, Yu
    Qu, Wei
    Ding, Li-Xiang
    MEDICAL SCIENCE MONITOR, 2019, 25 : 9483 - 9489
  • [7] Screw omission and the stability of posterior pedicle screw constructs for short-segment stabilization
    Margulies, JY
    Casar, RS
    Neuwirth, MG
    Margulies, SD
    Kummer, FJ
    JOURNAL OF SPINAL DISORDERS, 1997, 10 (03): : 240 - 245
  • [8] Radiologic and Functional Outcomes in Unstable Thoracolumbar Fractures Treated With Short-segment Pedicle Instrumentation
    Rojas-Tomba, Facundo
    Hernandez-Ruiz, Angel
    Menendez-Quintanilla, Ismael
    Garcia de Quevedo-Puerta, David
    Moriel-Duran, Jose
    Villanueva-Pareja, Francisco
    CLINICAL SPINE SURGERY, 2017, 30 (10): : 459 - 465
  • [9] Treatment of thoracolumbar burst fractures : short-segment pedicle instrumentation versus kyphoplasty
    Zhang, Lei
    Zou, Jun
    Gan, Minfeng
    San, Jinhui
    Li, Jigang
    Yang, Huilin
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (06): : 718 - 725
  • [10] Successful Treatment of Thoracolumbar Fractures With Short-segment Pedicle Instrumentation
    Gelb, Daniel
    Ludwig, Steven
    Karp, Jacqueline E.
    Chung, Edward H.
    Werner, Clement
    Kim, Terrence
    Poelstra, Kornelis
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (05): : 293 - 301