A New Self-Calibration Method of an LCR Meter for RF Resistance Calibration Using Capacitance Standards

被引:4
|
作者
Suzuki, Kiyoshi [1 ]
机构
[1] Agilent Technol Int Japan Ltd, Measurement Stand Ctr, Tokyo 1920033, Japan
关键词
Capacitance measurement; measurement errors; phase measurement; phase shifters; resistance measurement; signal detection;
D O I
10.1109/TIM.2008.2008080
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes how to calibrate a four-terminal-pair (4TP) LCR meter at the right (90 degrees) angle. The LCR meter uses the right angle signal to process a synchronous detector as a vector signal receiver. The right-angle calibration method uses, at a minimum, one variable-phase signal generator (SG) and a phase shift circuit. The SG does not require a precision right angle, but it does need good phase stability. The described phase shifter provides the required differential phase of nearly the right angle. As a result, the right-angle phase deviation of the LCR meter is better than 65 mu rad (0.223') with 37-mu rad (0.127') uncertainty at 10 MHz. This method is also applicable to the phase calibration of a vector network analyzer.
引用
收藏
页码:993 / 996
页数:4
相关论文
共 50 条
  • [41] A Self-Calibration Method for Rotational Stereo Vision
    Guo, Beili
    Guan, Qiu
    Chen, S. Y.
    2009 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, VOL III, PROCEEDINGS, 2009, : 128 - 132
  • [42] Measurement data self-calibration fusion method
    Fu H.
    Yang H.
    Wen X.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2019, 34 (08): : 1759 - 1763
  • [43] On-wafer RF characterization of integrated silicon photonic transceivers with self-calibration method
    Zhang, S. J.
    Wang, H.
    Zou, X. H.
    Zhang, C.
    Liu, Y.
    Peters, J. D.
    Bowers, J. E.
    2017 INTERNATIONAL TOPICAL MEETING ON MICROWAVE PHOTONICS (MWP), 2017,
  • [44] A WEIGHTED ITERATIVE METHOD FOR ROBUST SELF-CALIBRATION
    Liu Shigang Wu Chengke Tang Li Jia Jing National Key Laboratory of ISN Xidian University Xian China
    JournalofElectronics, 2006, (05) : 713 - 717
  • [45] The self-calibration method of IR mixer with low IF
    Andrzej Szymański
    Ewa Kurjata-Pfitzner
    Jan Lesiński
    Jerzy Wąsowski
    Analog Integrated Circuits and Signal Processing, 2008, 55 : 115 - 124
  • [46] Self-calibration method for capacitor mismatch elimination
    Melikyan, Vazgen
    Aleksanyan, Ani
    Stepanyan, Harutyun
    Harutyunyan, Ani
    Durgaryan, Armen
    PROCEEDINGS OF IEEE EAST-WEST DESIGN & TEST SYMPOSIUM (EWDTS 2013), 2013,
  • [47] Self-Calibration of Joint RF Impairments in a Loopback Wideband Transceiver
    Deng, Juinn-Horng
    Lee, Chia-Fang
    Ku, Meng-Lin
    Hwang, Jeng-Kuang
    IEEE ACCESS, 2020, 8 (08): : 45607 - 45617
  • [48] New linear camera self-calibration technique
    Li, Hua
    Wu, Fu-Chao
    Hu, Zhan-Yi
    Jisuanji Xuebao/Chinese Journal of Computers, 2000, 23 (11): : 1121 - 1129
  • [49] A New Resistive Voltage Divider with Self-Calibration
    Zhao, Wenpeng
    Shi, Yang
    Qian, Lushuai
    Zhang, Dandan
    Zhao, Jianting
    2024 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CPEM 2024, 2024,
  • [50] New self-calibration schemes for accelerometers of platform
    Li Chan
    Cao Yuan
    Ding Zhi-jian
    Cai Hong
    26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 1181 - 1185