Neodymium oxide: A new thermoluminescent material for gamma dosimetry

被引:19
|
作者
Soliman, C. [1 ]
机构
[1] Ain Shams Univ, Fac Sci, Dept Phys, Cairo, Egypt
关键词
thermoluminescence; gamma dose; glow curve; pre-heating; dosimetry; THERMO-LUMINESCENCE; RADIATION DEFECTS;
D O I
10.1016/j.nimb.2006.07.027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the present study thermoluminescence (TL) glow curves of commercial and gamma (0.001 Gy to 100 kGy) exposed neodymium oxide (Nd2O3) have been investigated. The commercial glow curve is simple with TL peaks at 310, 350 and 385 degrees C. The TL sensitivity was enhanced to similar to 4.7 times the original value when the investigated material was subject to pre-heating treatment at 800 degrees C for 1 h. The effect of storage time at room temperature has been monitored for different gamma-doses. The combination of good gamma-dose response and high stability of defects offer the possibility of applying the investigated material to gamma-ray dosimetry in radiotherapy and experimental radiology range. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:441 / 444
页数:4
相关论文
共 50 条
  • [31] THERMOLUMINESCENT DOSIMETRY FOR DETERMINING GAMMA HEATING IN ZERO-POWER FAST-REACTORS
    YLE, TJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1972, 15 (01): : 537 - &
  • [32] ELECTROCHEMICALLY PRODUCED ALUMINA-ON-ALUMINUM ALLOYS AS THERMOLUMINESCENT DOSIMETER FOR GAMMA AND ELECTRON DOSIMETRY
    STENGER, V
    OSVAY, M
    TORDAY, Z
    PAPP, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3): : 702 - 707
  • [33] GAMMA-RADIATION DOSIMETRY USING A NACL-BA(T) THERMOLUMINESCENT PHOSPHOR
    MAHAJAN, OH
    JOSHI, TR
    NAMBI, KSV
    JOSHI, RV
    HEALTH PHYSICS, 1986, 51 (01): : 127 - 133
  • [34] DOSIMETRIC USE OF BERYLLIUM OXIDE AS A THERMOLUMINESCENT MATERIAL - A PRELIMINARY STUDY
    SCARPA, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (04): : 667 - &
  • [35] PERSONNEL DOSIMETRY USING THERMOLUMINESCENT DOSIMETERS
    CUSIMANO, JP
    CIPPERLEY, FV
    HEALTH PHYSICS, 1968, 14 (04): : 339 - +
  • [36] SIMPLE VACUUM TWEEZER FOR THERMOLUMINESCENT DOSIMETRY
    KOCI, J
    HAVA, L
    SPURNY, Z
    JADERNA ENERGIE, 1978, 24 (02): : 60 - 60
  • [37] IMPROVEMENTS MADE TO A THERMOLUMINESCENT DOSIMETRY SYSTEM
    WHITE, AJ
    HEALTH PHYSICS, 1985, 49 (02): : 361 - 361
  • [38] Thermoluminescent dosimetry in total body irradiation
    Rodriguez-Cortes, J.
    Rivera-Montalvo, T.
    Villasenor Navarro, L. F.
    Flores-Lopez, O.
    Roman, J.
    Hernandez-Oviedo, J. O.
    APPLIED RADIATION AND ISOTOPES, 2012, 71 : 35 - 39
  • [39] RADIOIMMUNOTHERAPY DOSIMETRY USING THERMOLUMINESCENT DOSIMETERS
    SULLIVAN, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (06): : 734 - 735
  • [40] INTRINSIC EFFICIENCY OF THERMOLUMINESCENT DOSIMETRY PHOSPHORS
    LUCKE, WH
    REPORT OF NRL PROGRESS, 1970, : 23 - &