Neodymium oxide: A new thermoluminescent material for gamma dosimetry

被引:19
|
作者
Soliman, C. [1 ]
机构
[1] Ain Shams Univ, Fac Sci, Dept Phys, Cairo, Egypt
关键词
thermoluminescence; gamma dose; glow curve; pre-heating; dosimetry; THERMO-LUMINESCENCE; RADIATION DEFECTS;
D O I
10.1016/j.nimb.2006.07.027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the present study thermoluminescence (TL) glow curves of commercial and gamma (0.001 Gy to 100 kGy) exposed neodymium oxide (Nd2O3) have been investigated. The commercial glow curve is simple with TL peaks at 310, 350 and 385 degrees C. The TL sensitivity was enhanced to similar to 4.7 times the original value when the investigated material was subject to pre-heating treatment at 800 degrees C for 1 h. The effect of storage time at room temperature has been monitored for different gamma-doses. The combination of good gamma-dose response and high stability of defects offer the possibility of applying the investigated material to gamma-ray dosimetry in radiotherapy and experimental radiology range. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:441 / 444
页数:4
相关论文
共 50 条
  • [21] DyF3: A promising new TL material for gamma dosimetry
    Soliman, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (14): : 2423 - 2426
  • [22] A COMPARISON OF THERMOLUMINESCENT DOSIMETRY AND FILM FOR PERSONNEL DOSIMETRY
    SUNTHARA.N
    CAMERON, JR
    HEALTH PHYSICS, 1966, 12 (08): : 1181 - +
  • [23] ENVIRONMENTAL GAMMA DOSIMETRY USING CASO4-DY THERMOLUMINESCENT DOSIMETERS
    VOHRA, KG
    BHATT, RC
    CHANDRA, B
    PRADHAN, AS
    LAKSHMANAN, AR
    HEALTH PHYSICS, 1981, 40 (04): : 575 - 575
  • [24] RADIOCARBON DATING BY THERMOLUMINESCENT DOSIMETRY
    WINTER, J
    ARCHAEOMETRY, 1972, 14 (AUG) : 281 - 286
  • [25] The predose effect in thermoluminescent dosimetry
    Itoh, N
    Stoneham, D
    Stoneham, AM
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2001, 13 (10) : 2201 - 2209
  • [26] A THERMOLUMINESCENT DOSEMETER AND DOSIMETRY READER
    MIHAILOVIC, M
    KOSI, V
    MIHAILOV.MV
    MILAVEC, Z
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 150 - +
  • [27] A PRELIMINARY STUDY OF THERMOLUMINESCENT DOSIMETRY
    MALSKY, SJ
    AMATO, CG
    ROSWIT, B
    REID, CB
    SPRECKELS, C
    RADIOLOGY, 1962, 78 (02) : 277 - 277
  • [28] THERMOLUMINESCENT DOSIMETRY WITH POLYCRISTALLINE LIF
    STOLZ, W
    LOHSE, U
    DEMKO, M
    WALTER, R
    ATOMPRAXIS, 1970, 16 (05): : 309 - &
  • [29] PION DOSIMETRY WITH THERMOLUMINESCENT MATERIALS
    HOFFMANN, W
    MOLLER, G
    BLATTMANN, H
    SALZMANN, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (05): : 913 - 921
  • [30] SPECIAL APPLICATIONS OF THERMOLUMINESCENT DOSIMETRY
    CUSIMANO, JP
    CIPPERLE.FV
    CULLEY, JC
    HEALTH PHYSICS, 1968, 15 (02): : 178 - +