Response calculation for standard ionization chambers in the APMP using EGS4 Monte Carlo code

被引:7
|
作者
Sato, Yasushi
Yunoki, Akira
Hino, Yoshio
Yamada, Takahiro
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058568, Japan
[2] Japan Radioisotope Assoc, Tokyo 1138941, Japan
关键词
ionization chamber; Monte Carlo calculation; calibration factors; Ho-166m; Apmp;
D O I
10.1016/j.apradiso.2006.02.023
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In the APMP radioactivity group (TCRI), a series of intercomparisons were conducted between member laboratories, with the aim to improve the calibration of ionization chambers used as secondary standards for radioactivity measurement. Several sources were sent to the participating institutes and the measurement results of calibration factors have been compared. Good agreement between laboratories was found for radioisotopes where the major contribution to the ionization current stems from high-energy gamma rays. It was expected in this energy region that these ratios would become unity for any type of chamber by normalizing with the same type of reference sources. However, where the dominating contribution to the measured ionization current is due to the presence of low-energy gamma rays, there were some serious discrepancies between participating institutes. In order to understand these differences, Monte Carlo simulation has been utilized by studying the effects of changing the wall thickness of the re-entrant well, the materials of the sample holder and the composition of the ionizing gas. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1211 / 1214
页数:4
相关论文
共 50 条
  • [41] Monte Carlo simulation of mammography X-ray units:: A comparison between different electron extensions of the EGS4 code system
    Marziani, M
    Gambaccini, M
    Távora, LMN
    Taibi, A
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 351 - 356
  • [42] Monte Carlo calculation of the compensation ability of ionization chambers in tritium measurements
    Chen Zhilin
    Wei Xiye
    Mu Long
    Wang Heyi
    Chang Ruimin
    Wu Guanyin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 613 (02): : 304 - 307
  • [43] Application of the EGS4 Monte Carlo code to a study of multilayer gamma-ray exposure buildup factors of up to 40 mfp
    Hirayama, H
    Shin, K
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1998, 35 (11) : 816 - 829
  • [44] The relative impact of scatter on absolute myocardial perfusion quantitation: An EGS4 Monte Carlo study
    Tang, HR
    Da Silva, AJ
    Hasegawa, BH
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1224 - 1228
  • [45] The dose distribution close to an Ir-192 wire source: EGS4 Monte Carlo calculations
    Cheung, YC
    Yu, PKN
    Young, ECM
    Chan, CL
    Ng, MF
    Tang, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02): : 401 - 406
  • [46] Calculation of the Effects of Silver (Ag) Dopant on Radiation Shielding Efficiency of BiPbSrCaCuO Superconductor Ceramics Using EGS4 Code
    Kaya, Selim
    APPLIED SCIENCES-BASEL, 2023, 13 (14):
  • [47] EGS4 Monte Carlo simulation of a 90° geometry polarized X-ray fluorescence system
    Fayez, HHA
    RADIATION PHYSICS AND CHEMISTRY, 1999, 55 (04) : 377 - 384
  • [48] Dose distributions at extreme irradiation depths of gamma knife radiosurgery: EGS4 Monte Carlo calculations
    Cheung, JYC
    Yu, KN
    Yu, CP
    Ho, RTK
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (03) : 461 - 465
  • [49] Simulation of the response of the IG11 4πγ ionization chamber using GEANT Monte Carlo code
    Gostely, JJ
    Laedermann, JP
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 447 - 453
  • [50] Photon production using a low energy electron expansion of the EGS4 code system
    Tavora, L.M.N.
    Morton, E.J.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1998, 143 (03): : 253 - 271