Response calculation for standard ionization chambers in the APMP using EGS4 Monte Carlo code

被引:7
|
作者
Sato, Yasushi
Yunoki, Akira
Hino, Yoshio
Yamada, Takahiro
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058568, Japan
[2] Japan Radioisotope Assoc, Tokyo 1138941, Japan
关键词
ionization chamber; Monte Carlo calculation; calibration factors; Ho-166m; Apmp;
D O I
10.1016/j.apradiso.2006.02.023
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In the APMP radioactivity group (TCRI), a series of intercomparisons were conducted between member laboratories, with the aim to improve the calibration of ionization chambers used as secondary standards for radioactivity measurement. Several sources were sent to the participating institutes and the measurement results of calibration factors have been compared. Good agreement between laboratories was found for radioisotopes where the major contribution to the ionization current stems from high-energy gamma rays. It was expected in this energy region that these ratios would become unity for any type of chamber by normalizing with the same type of reference sources. However, where the dominating contribution to the measured ionization current is due to the presence of low-energy gamma rays, there were some serious discrepancies between participating institutes. In order to understand these differences, Monte Carlo simulation has been utilized by studying the effects of changing the wall thickness of the re-entrant well, the materials of the sample holder and the composition of the ionizing gas. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1211 / 1214
页数:4
相关论文
共 50 条
  • [21] Energy response simulation of 4π gamma ionization chambers using Monte Carlo technique
    Aleissa, KA
    MEDICAL PHYSICS, 2002, 29 (12) : 2840 - 2844
  • [22] Calculation of beam quality correction factors for various thimble ionization chambers using the Monte Carlo code PENELOPE
    Erazo, Fabian
    Lallena, Antonio M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (02): : 163 - 170
  • [23] SYNCHROTRON-RADIATION CALCULATIONS USING THE EGS4 CODE
    LIU, JC
    NELSON, WR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 360 (03): : 626 - 633
  • [24] Determination of individual S-values for I-131 using segmented CT data and the EGS4 Monte Carlo code
    Wolf, I
    Zankl, M
    Scheidhauer, K
    Vabuliene, E
    Regulla, D
    von Schilling, C
    Schwaiger, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S475 - S475
  • [25] Monte Carlo simulation of dose distributions from a synchrotron-produced microplanar beam array using the EGS4 code system
    Orion, I
    Rosenfeld, AB
    Dilmanian, FA
    Telang, F
    Ren, B
    Namito, Y
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2497 - 2508
  • [26] Determination of individual S-values for 131I using segmented CT data and the EGS4 Monte Carlo code
    Wolf, I
    Zankl, M
    Scheidhauer, K
    Vabuliene, E
    Regulla, D
    von Schilling, C
    Schwaiger, M
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2005, 20 (01) : 98 - 102
  • [27] INCORPORATION OF SINGLE ELASTIC-SCATTERING IN THE EGS4 MONTE-CARLO CODE SYSTEM - TESTS OF MOLIERE THEORY
    BIELAJEW, AF
    WANG, RQ
    DUANE, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 82 (04): : 503 - 512
  • [28] DOSE3D: EGS4 Monte Carlo code-based software for internal radionuclide dosimetry
    Clairand, I
    Ricard, M
    Gouriou, J
    Di Paola, M
    Aubert, B
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (09) : 1517 - 1523
  • [29] EGS4 MONTE-CARLO DETERMINATION OF THE BETA-DOSE KERNEL IN WATER
    SIMPKIN, DJ
    MACKIE, TR
    MEDICAL PHYSICS, 1990, 17 (02) : 179 - 186
  • [30] Monte Carlo dose calculation for HDR brachytherapy source using EGS5 code
    Badry, H.
    Oufni, L.
    Ouabi, H.
    Hirayama, H.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 150 : 76 - 81