Time-lapse X-ray phase-contrast microtomography for in vivo imaging and analysis of morphogenesis

被引:111
|
作者
Moosmann, Julian [1 ]
Ershov, Alexey [1 ,2 ]
Weinhardt, Venera [3 ,4 ]
Baumbach, Tilo [1 ,3 ]
Prasad, Maneeshi S. [5 ]
LaBonne, Carole [5 ]
Xiao, Xianghui [6 ]
Kashef, Jubin [7 ]
Hofmann, Ralf [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Photon Sci & Synchrotron Radiat, Eggenstein Leopoldshafen, Germany
[2] Natl Res Tomsk Polytech Univ, Inst Phys & Technol, Dept Gen Phys, Tomsk, Russia
[3] Karlsruhe Inst Technol, Lab Applicat Synchrotron Radiat, D-76021 Karlsruhe, Germany
[4] Heidelberg Univ, Ctr Organismal Studies, Heidelberg, Germany
[5] Northwestern Univ, Dept Mol Biosci, Evanston, IL USA
[6] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[7] Karlsruhe Inst Technol, Inst Zool 2, D-76021 Karlsruhe, Germany
关键词
EMBRYO;
D O I
10.1038/nprot.2014.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
X-ray phase-contrast microtomography (XPC mu T) is a label-free, high-resolution imaging modality for analyzing early development of vertebrate embryos in vivo by using time-lapse sequences of 3D volumes. Here we provide a detailed protocol for applying this technique to study gastrulation in Xenopus laevis (African clawed frog) embryos. In contrast to mu MRI, XPC mu T images optically opaque embryos with subminute temporal and micrometer-range spatial resolution. We describe sample preparation, culture and suspension of embryos, tomographic imaging with a typical duration of 2 h (gastrulation and neurulation stages), intricacies of image pre-processing, phase retrieval, tomographic reconstruction, segmentation and motion analysis. Moreover, we briefly discuss our present understanding of X-ray dose effects (heat load and radiolysis), and we outline how to optimize the experimental configuration with respect to X-ray energy, photon flux density, sample-detector distance, exposure time per tomographic projection, numbers of projections and time-lapse intervals. The protocol requires an interdisciplinary effort of developmental biologists for sample preparation and data interpretation, X-ray physicists for planning and performing the experiment and applied mathematicians/computer scientists/physicists for data processing and analysis. Sample preparation requires 9-48 h, depending on the stage of development to be studied. Data acquisition takes 2-3 h per tomographic time-lapse sequence. Data processing and analysis requires a further 2 weeks, depending on the availability of computing power and the amount of detail required to address a given scientific problem.
引用
收藏
页码:294 / 304
页数:11
相关论文
共 50 条
  • [41] FERTILIZATION INVITRO - A STUDY BY PHASE-CONTRAST MICROSCOPY AND TIME-LAPSE CINEMATOGRAPHY
    GADDUMROSSE, P
    BLANDAU, RJ
    SATO, K
    JOURNAL OF ANATOMY, 1982, 135 (DEC) : 833 - 833
  • [43] Noise analysis of speckle-based x-ray phase-contrast imaging
    Zhou, Tunhe
    Zdora, Marie-Christine
    Zanette, Irene
    Romell, Jenny
    Hertz, Hans M.
    Burvall, Anna
    OPTICS LETTERS, 2016, 41 (23) : 5490 - 5493
  • [44] Phase-space formulation for phase-contrast x-ray imaging
    Wu, XZ
    Liu, H
    APPLIED OPTICS, 2005, 44 (28) : 5847 - 5854
  • [45] Image Fusion in X-Ray Differential Phase-Contrast Imaging
    Haas, W.
    Polyanskaya, M.
    Bayer, F.
    Goedel, K.
    Hofmann, H.
    Rieger, J.
    Ritter, A.
    Weber, T.
    Wucherer, L.
    Durst, J.
    Michel, T.
    Anton, G.
    Hornegger, J.
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [46] Phase-contrast x-ray imaging for nondestructive evaluation of materials
    Zoofan, B.
    Kim, J. -Y.
    Rokhlin, S. I.
    Frankel, G. S.
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (01)
  • [47] Phase retrieval in X-ray phase-contrast imaging suitable for tomography
    Burvall, Anna
    Lundstrom, Ulf
    Takman, Per A. C.
    Larsson, Daniel H.
    Hertz, Hans M.
    OPTICS EXPRESS, 2011, 19 (11): : 10359 - 10376
  • [48] Vessel imaging by interferometric phase-contrast x-ray technique
    Takeda, T
    Momose, A
    Wu, J
    Yu, QW
    Zeniya, T
    Thet-Thet-Lwin
    Yoneyama, A
    Itai, Y
    CIRCULATION, 2002, 105 (14) : 1708 - 1712
  • [49] Phase-contrast and fluorescent X-ray imaging for biomedical researches
    Takeda, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 38 - 46
  • [50] Edge-illumination x-ray phase-contrast imaging
    Olivo, Alessandro
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2021, 33 (36)