Time-lapse X-ray phase-contrast microtomography for in vivo imaging and analysis of morphogenesis

被引:111
|
作者
Moosmann, Julian [1 ]
Ershov, Alexey [1 ,2 ]
Weinhardt, Venera [3 ,4 ]
Baumbach, Tilo [1 ,3 ]
Prasad, Maneeshi S. [5 ]
LaBonne, Carole [5 ]
Xiao, Xianghui [6 ]
Kashef, Jubin [7 ]
Hofmann, Ralf [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Photon Sci & Synchrotron Radiat, Eggenstein Leopoldshafen, Germany
[2] Natl Res Tomsk Polytech Univ, Inst Phys & Technol, Dept Gen Phys, Tomsk, Russia
[3] Karlsruhe Inst Technol, Lab Applicat Synchrotron Radiat, D-76021 Karlsruhe, Germany
[4] Heidelberg Univ, Ctr Organismal Studies, Heidelberg, Germany
[5] Northwestern Univ, Dept Mol Biosci, Evanston, IL USA
[6] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[7] Karlsruhe Inst Technol, Inst Zool 2, D-76021 Karlsruhe, Germany
关键词
EMBRYO;
D O I
10.1038/nprot.2014.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
X-ray phase-contrast microtomography (XPC mu T) is a label-free, high-resolution imaging modality for analyzing early development of vertebrate embryos in vivo by using time-lapse sequences of 3D volumes. Here we provide a detailed protocol for applying this technique to study gastrulation in Xenopus laevis (African clawed frog) embryos. In contrast to mu MRI, XPC mu T images optically opaque embryos with subminute temporal and micrometer-range spatial resolution. We describe sample preparation, culture and suspension of embryos, tomographic imaging with a typical duration of 2 h (gastrulation and neurulation stages), intricacies of image pre-processing, phase retrieval, tomographic reconstruction, segmentation and motion analysis. Moreover, we briefly discuss our present understanding of X-ray dose effects (heat load and radiolysis), and we outline how to optimize the experimental configuration with respect to X-ray energy, photon flux density, sample-detector distance, exposure time per tomographic projection, numbers of projections and time-lapse intervals. The protocol requires an interdisciplinary effort of developmental biologists for sample preparation and data interpretation, X-ray physicists for planning and performing the experiment and applied mathematicians/computer scientists/physicists for data processing and analysis. Sample preparation requires 9-48 h, depending on the stage of development to be studied. Data acquisition takes 2-3 h per tomographic time-lapse sequence. Data processing and analysis requires a further 2 weeks, depending on the availability of computing power and the amount of detail required to address a given scientific problem.
引用
收藏
页码:294 / 304
页数:11
相关论文
共 50 条
  • [31] Phase-contrast imaging with a novel X-ray source
    Takahashi, Yumiko
    Hayakawa, Yasushi
    Kuwada, Takao
    Sakai, Takeshi
    Nakao, Keisuke
    Nogami, Kyoko
    Imagaki, Manabu
    Tanaka, Toshinari
    Hayakawa, Ken
    Sato, Isamu
    X-RAY OPTICS AND MICROANALYSIS, PROCEEDINGS, 2010, 1221 : 119 - +
  • [32] Comprehensive characterization of TSV etching performance with phase-contrast X-ray microtomography
    Li, Ke
    Deng, Biao
    Zhang, Haipeng
    Yu, Fucheng
    Xue, Yanling
    Xie, Changqing
    Ye, Tianchun
    Xiao, Tiqiao
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 1023 - 1032
  • [33] Phase-contrast X-ray microtomography links Cretaceous seeds with Gnetales and Bennettitales
    Else Marie Friis
    Peter R. Crane
    Kaj Raunsgaard Pedersen
    Stefan Bengtson
    Philip C. J. Donoghue
    Guido W. Grimm
    Marco Stampanoni
    Nature, 2007, 450 : 549 - 552
  • [34] Phase-contrast X-ray imaging with a large monolithic X-ray interferometer
    Takeda, T
    Momose, A
    Yu, QW
    Wu, J
    Hirano, K
    Itai, Y
    JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 (07) : 280 - 282
  • [35] Quantitative characterization and diagnosis via hard X-ray phase-contrast microtomography
    Liu, Huiqiang
    Ji, Xuewen
    Ma, Yan
    Du, Guohao
    Fu, Yanan
    Abudureheman, Yibanu
    Liu, Wenya
    MICROSCOPY RESEARCH AND TECHNIQUE, 2018, 81 (10) : 1173 - 1181
  • [36] Phase-contrast hard X-ray microtomography by Bragg-Fresnel optics
    Hartman, Y
    Kohn, V
    Kuznetsov, S
    Snigirev, A
    Snigireva, I
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA D-CONDENSED MATTER ATOMIC MOLECULAR AND CHEMICAL PHYSICS FLUIDS PLASMAS BIOPHYSICS, 1997, 19 (2-4): : 571 - 576
  • [37] On the origin of contrast in edge illumination X-ray phase-contrast imaging
    Diemoz, Paul C.
    Olivo, Alessandro
    OPTICS EXPRESS, 2014, 22 (23): : 28199 - 28214
  • [38] In vivo Dynamic Phase-Contrast X-ray Imaging using a Compact Light Source
    Gradl, Regine
    Dierolf, Martin
    Guenther, Benedikt
    Hehn, Lorenz
    Moeller, Winfried
    Kutschke, David
    Yang, Lin
    Donnelley, Martin
    Murrie, Rhiannon
    Erl, Alexander
    Stoeger, Tobias
    Gleich, Bernhard
    Achterhold, Klaus
    Schmid, Otmar
    Pfeiffer, Franz
    Morgan, Kaye Susannah
    SCIENTIFIC REPORTS, 2018, 8
  • [39] In vivo Dynamic Phase-Contrast X-ray Imaging using a Compact Light Source
    Regine Gradl
    Martin Dierolf
    Benedikt Günther
    Lorenz Hehn
    Winfried Möller
    David Kutschke
    Lin Yang
    Martin Donnelley
    Rhiannon Murrie
    Alexander Erl
    Tobias Stoeger
    Bernhard Gleich
    Klaus Achterhold
    Otmar Schmid
    Franz Pfeiffer
    Kaye Susannah Morgan
    Scientific Reports, 8
  • [40] Single grating phase contrast imaging for x-ray microscopy and microtomography
    Bruyndonckx, P.
    Sasov, A.
    Pauwels, B.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212