Determination of Theophylline at a Cysteic Acid Modified Glassy Carbon Electrode

被引:40
|
作者
Brunetti, Barbara [1 ]
Desimoni, Elio [1 ]
机构
[1] Univ Milan, DISTAM, I-20133 Milan, Italy
关键词
Modified electrodes; Cysteine; Cysteic acid; Theophylline; Voltammetry; PARTIAL LEAST-SQUARES; PERFORMANCE LIQUID-CHROMATOGRAPHY; CONDUCTIVE DIAMOND ELECTRODES; CHEMICALLY-MODIFIED ELECTRODE; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL OXIDATION; AMPEROMETRIC DETECTION; CAFFEINE; THEOBROMINE; HPLC;
D O I
10.1002/elan.200804477
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode modified with electrodeposited cysteic acid is proposed for the determination of theophylline. Estimation of the linear range, calibration function and limit of detection. as well as determination in real samples such as medication tablets were performed. According to the results. such a modified electrode appears to be a straightforward alternative to common glassy carbon or other modified electrodes. This thanks to the affinity of cysteic acid to the analyte, the low cost, the simplicity of the modification procedure and the reproducibility of the electrode surface.
引用
收藏
页码:772 / 778
页数:7
相关论文
共 50 条
  • [31] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502
  • [32] An L-cysteic acid-modified screen-printed carbon electrode for methyl parathion determination
    Majer, David
    Finsgar, Matjaz
    MICROCHEMICAL JOURNAL, 2022, 183
  • [33] Electrochemical determination of ascorbic acid using Cu sulfide modified glassy carbon electrode
    Pei L.Z.
    Lin N.
    Wei T.
    Liu H.D.
    Cai Z.Y.
    Surface Engineering and Applied Electrochemistry, 2016, 52 (6) : 565 - 571
  • [34] Poly(Acid Chrome Blue K) Modified Glassy Carbon Electrode for the Determination of Vanillin
    Luo, Shaohua
    Liu, Yuxia
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (07): : 6396 - 6405
  • [35] Study on Electrochemical Behaviors and Determination of Xanthine and Uric Acid on Modified Glassy Carbon Electrode
    Sun Kai
    Sun Deng-Ming
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (07) : 991 - 996
  • [36] Electrochemical Determination of Bisphenol A Based on Poly(Chromotropic Acid) Modified Glassy Carbon Electrode
    Filik, Hayati
    Avan, Asiye Aslihan
    CURRENT ANALYTICAL CHEMISTRY, 2017, 13 (06) : 464 - 473
  • [37] Determination of l-DOPA at an optimized caffeic acid modified glassy carbon electrode
    Far, Ahmad Rohani
    Devasurendra, Amila
    Young, Joshua
    Kirchhoff, Jon
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [38] Voltammetric Determination of Gallic Acid with a Glassy Carbon Electrode modified with Reduced Graphene Oxide
    Lisnund, Sireerat
    Blay, Vincent
    Chansaenpak, Kantapat
    Pinyou, Piyanut
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 7214 - 7227
  • [40] Simultaneous Determination of Epinephrine and Uric Acid at Poly (Guanine) Modified Glassy Carbon Electrode
    Li, Hongying
    Wang, Xueliang
    ELECTROCHEMISTRY, 2015, 83 (06) : 434 - 439