PET Performance Evaluation of an MR-Compatible PET Insert

被引:32
|
作者
Wu, Yibao [1 ]
Catana, Ciprian [2 ]
Farrell, Richard [3 ]
Dokhale, Purushottam A. [3 ]
Shah, Kanai S. [3 ]
Qi, Jinyi [1 ]
Cherry, Simon R. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[3] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
基金
美国国家卫生研究院;
关键词
Avalanche photodiodes; positron emission tomography (PET); magnetic resonance imaging (MRI); POSITRON-EMISSION-TOMOGRAPHY; SENSITIVE AVALANCHE PHOTODIODES; SMALL ANIMAL PET; SIMULTANEOUS PET/MRI; SCANNER; MICROPET; DETECTOR; DESIGN; ACQUISITION; RESOLUTION;
D O I
10.1109/TNS.2009.2015448
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A magnetic resonance (MR) compatible positron emission tomography (PET) insert has been developed in our laboratory for simultaneous small animal PET/MR imaging. This system is based on lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiode (PSAPD) photodetectors. The PET performance of this insert has been measured. The average reconstructed image spatial resolution was 1.51 mm. The sensitivity at the center of the field of view (CFOV) was 0.35%, which is comparable to the simulation predictions of 0.40%. The average photopeak energy resolution was 25%. The scatter fraction inside the MRI scanner with a line source was 12% (with a mouse-sized phantom and standard 35 mm Bruker 1H RF coil), 7% (with RF coil only) and 5% (without phantom or RF coil) for an energy window of 350-650 keV. The front-end electronics had a dead time of 390 ns, and a trigger extension dead time of 7.32 mu s that degraded counting rate performance for injected doses above similar to 0.75 mCi (28 MBq). The peak noise-equivalent count rate (NECR) of 1.27 kcps was achieved at 290 mu Ci (10.7 MBq). The system showed good imaging performance inside a 7-T animal MRI system; however improvements in data acquisition electronics and reduction of the coincidence timing window are needed to realize improved NECR performance.
引用
收藏
页码:574 / 580
页数:7
相关论文
共 50 条
  • [31] A multi-slice dual layer MR-compatible animal PET system: K-PET I
    Yamamoto, S.
    Mashino, H.
    Takamatsu, S.
    Matsumoto, K.
    Senda, M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1708 - +
  • [32] PET performance evaluation of a preclinical digital PET/MRI insert
    David Schug
    Christoph Lerche
    Peter Dueppenbecker
    Pierre Gebhardt
    Benjamin Goldschmidt
    Andre Salomon
    Jakob Wehner
    Bjoern Weissler
    Fabian Kiessling
    Volkmar Schulz
    EJNMMI Physics, 1 (Suppl 1)
  • [33] Optimization of a partially segmented block detector for MR-compatible small animal PET
    Hwang, Ji Yeon
    Chung, Yong Hyun
    Baek, Cheol-Ha
    An, Su Jung
    Kim, Hyun-Il
    Kim, Kwang Hyun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 815 - 818
  • [34] Performance simulation of a compact PET insert for simultaneous PET/MR breast imaging
    Liang, Yicheng
    Peng, Hao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 751 : 23 - 30
  • [35] Evaluation of a MR-compatible CZT detector
    Despres, Philippe
    Izaguirre, Enrique W.
    Liu, Siyuan
    Cirignano, Leonard J.
    Kim, Hadong
    Wendland, Michael F.
    Shah, Kanai S.
    Hasegawa, Bruce H.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4324 - +
  • [36] Preliminary PET performance evaluation of an RF field-penetrable brain-sized PET insert for simultaneous PET/MR imaging
    Chang, Chen-Ming
    Grant, Alexander
    Lee, Brian
    Levin, Craig
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [37] Performance Evaluation of a Newly Developed MR-Compatible Mobile PET Scanner with Two Detector Layouts (vol 22, pg 407, 2020)
    Watanabe, Masao
    Nakamoto, Yuji
    Nakamoto, Ryusuke
    Ishimori, Takayoshi
    Saga, Tsuneo
    Togashi, Kaori
    MOLECULAR IMAGING AND BIOLOGY, 2020, 22 (02) : 416 - 416
  • [38] Design and construction of a multi-slice, depth-of-interaction MR-compatible PET
    Takamatsu, S
    Yamamoto, S
    Murayama, H
    Minato, K
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3810 - 3813
  • [39] Performance Evaluation of SimPET-X, a PET Insert for Simultaneous Mouse Total-Body PET/MR Imaging
    Kim, Kyeong Yun
    Son, Jeong-Whan
    Kim, Kyuwan
    Chung, Yina
    Park, Ji Yong
    Lee, Yun-Sang
    Ko, Guen Bae
    Lee, Jae Sung
    MOLECULAR IMAGING AND BIOLOGY, 2021, 23 (05) : 703 - 713
  • [40] Performance Evaluation of SimPET-X, a PET Insert for Simultaneous Mouse Total-Body PET/MR Imaging
    Kyeong Yun Kim
    Jeong-Whan Son
    Kyuwan Kim
    Yina Chung
    Ji Yong Park
    Yun-Sang Lee
    Guen Bae Ko
    Jae Sung Lee
    Molecular Imaging and Biology, 2021, 23 : 703 - 713